scholarly journals A New Ritodrine Selective Electrode and its Pharmaceutical Application

2010 ◽  
Vol 7 (s1) ◽  
pp. S103-S110 ◽  
Author(s):  
Reda Ammar

A novel ritodrine hydrochloride ion-selective PVC membrane electrode based on ion-pair complex of ritodrine-tetra phenyl borate was prepared withdi-n-butyl phosphate as a plasticizer. The influences of membrane composition, temperature, pH of the test solution and foreign ions on the electrode performance were investigated. The electrode showed a Nernstian response over a wide ritodrine concentration range (1×10−5- 1×10−2M) with a slope of 59.33 mV decade−1and was found to be very selective, precise and usable within the pH range 3-7.5. The standard electrode potentials, E°, were determined at different temperatures and used to calculate the isothermal temperature coefficient (dE°/dT) of the electrode, which was 0.00075. The electrode was successfully used for potentiometric determination of ritodrine hydrochloride both in pure solutions and in pharmaceutical preparations.

1988 ◽  
Vol 71 (5) ◽  
pp. 1042-1045
Author(s):  
Adel F Shoukry ◽  
Sayed S Badawy

Abstract A PVC membrane electrode of the coated wire type was prepared which is selective for thioredazine. It showed a Nernstian response over a thioredazine concentration range 6.3 x 10 «to 2.5 x 10_3M, at 25°C, and was selective, precise, and usable within the pH range 2.1-7.0. The standard electrode potentials, E°, were determined at different temperatures and used to calculate the isothermal temperature coefficient of the electrode. The photoreaction occurring in thioredazine solution exposed to daylight did not affect the electrode performance. This reaction was investigated kinetically to determine its rate constant and half-life at different temperatures.


2013 ◽  
Vol 2013 ◽  
pp. 1-5
Author(s):  
Sulekh Chandra ◽  
Kusum Sharma ◽  
Adarsh Kumar

A polymeric membrane-based tin selective electrode was developed by using salicylaldehyde thiosemicarbazone (STSC). The best performance was recorded with a membrane composition of PVC : TBP : ionophore : NaTPB as 28 : 59 : 8 : 5 (w/w%). The Nernstian slope calculated from the calibration curve for Sn2+sensor was28.8±0.4 mV/decade. The detection limit of the sensor was2.10×10−8 M, in the linear concentration range of1.0×10−2−1.1×10−7 M. It was relatively fast response time (<8 s for concentration≥1.0×10−4and <12 s for concentration of≥1.0×10−6 M) and can be used for 9 months without any considerable divergence in potentials. The proposed sensor exhibit relatively good selectivity and high sensitivity for tin(II) as other mono-, di-, and trivalent cations and can be used in a pH range of 2.0–8.5. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of stannous in artificially made samples.


Molecules ◽  
2019 ◽  
Vol 24 (3) ◽  
pp. 420 ◽  
Author(s):  
Bang-Jin Wang ◽  
Ai-Hong Duan ◽  
Jun-Hui Zhang ◽  
Sheng-Ming Xie ◽  
Qiu-E Cao ◽  
...  

Porous organic cages (POCs) have attracted extensive attention due to their unique structures and tremendous application potential in numerous areas. In this study, an enantioselective potentiometric sensor composed of a polyvinyl chloride (PVC) membrane electrode modified with CC3-R POC material was used for the recognition of enantiomers of 2-amino-1-butanol. After optimisation, the developed sensor exhibited enantioselectivity toward S-2-amino-1-butanol ( log K S , R P o t = −0.98) with acceptable sensitivity, and a near-Nernstian response of 25.8 ± 0.3 mV/decade within a pH range of 6.0–9.0.


2011 ◽  
Vol 8 (s1) ◽  
pp. S467-S473 ◽  
Author(s):  
Mohammad Reza Abedi ◽  
Hassan Ali Zamani

A new Eu3+PVC membrane electrode based on 1,2-diaminopropane-N, N,N',N'-tetraacetic acid (DAPTA) as a suitable ionophore has been prepared and studied. The electrode shows a good selectivity for Eu(III) ion with respect to most common cations including alkali, alkaline earth, transition and heavy metal ions. This electrode has a wide linear dynamic range from 1.0×10-6to 1.0×10-2M with a Nernstian slope of 19.7±0.5 mV per decade and a low detection limit of 7.2×10-7M in the pH range of 2.5–9.1, while the response time was rapid (<10 s). The practical utility of the electrodes has been demonstratedby their use as indicator electrodes in the potentiometric titration of Eu3+ions with EDTA and for the determination of Eu3+in some water sample solutions.


2020 ◽  
Vol 40 (6) ◽  
pp. 481-485 ◽  
Author(s):  
Shankar Suman ◽  
Ram Singh

AbstractA synthesized Schiff base 2-acetylthiophene semicarbazone (3) was used for the preparation of Ni2+ selective polyvinyl chloride (PVC) membrane electrode. The prepared electrode with the optimized composition, PVC:3:sodium tetraphenylborate:di-n-butylphthalate as 33:6:3:58 exhibited a Nernstian response over the working range of 5.0 × 10−6–5.0 × 10−2 mol l−1 with a slope of 29.0 ± 0.3 mV/concentration. The electrode showed good selectivity towards Ni2+ with respect to several metal ions in the pH range of 2.5–10.0 in <15 s with a detection limit of 4.7 × 10−6 mol l−1. The electrode showed the additional benefit of working in partially nonaqueous media having up to 15% (v/v) methanol or ethanol. This electrode was also successfully applied in Ni2+ ion potentiometric titration with ethylenediaminetetraacetic acid as an indicator electrode.


2010 ◽  
Vol 5 (1) ◽  
pp. 73-77
Author(s):  
Mihail Revenco ◽  
Mariana Martin ◽  
Waell Abu Dayyih

A potentiometric selective sensor based on trinuclear chromium(III) complex as a novel ionophore for the thiocyanateselective electrode is reported. The sensor displays a near Nernstian slope of 57 ± 2 mV per decade, over a wide pH range 3 - 11. The working concentration range of the electrode is 1.10-5 – 1.10-1 mol/l with a detection limit of 5.10-6 mol/l. The sensor has a response time of 20 s and can be used for at least 6 months without any considerable fluctuation of the potential. The selectivity coefficients determined at using the fixed interference method indicate a good discriminating ability towards other anions. The prepared sensor was applied as an indicator electrode in the titration of thiocyanate with Ag+.


2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Sulekh Chandra ◽  
Kusum Sharma ◽  
Adarsh Kumar

A PVC-membrane-based Mg(II) selective electrode was constructed using methyl phenyl semicarbazone (MPS) as a neutral carrier. The sensor exhibits a Nernstian response for Mg(II) ion over a wide concentration range1.0×10-8  to  1.0×10-1 M with the slope of 28.4 mV/per decade having detection limit1.7×10-9 M. It was relatively a fast response time (<10 s for concentration≥1.0×10-3and<15 s for concentration of≥1.0×10-6 M) and can be used for 8 months without any considerable divergence in potentials. The proposed sensor revealed relatively good selectivity and high sensitivity for Mg(II) over a mono-, di-, and trivalent cation and can be used in a pH range of 1.0–9.5. It was also successfully used as an indicator electrode in potentiometer titration and in the analysis of concentration of magnesium in various real samples.


2020 ◽  
Vol 40 (10) ◽  
pp. 842-847
Author(s):  
Shankar Suman ◽  
Ram Singh

AbstractA new poly (vinyl chloride) (PVC) membrane electrode using 2-benzoylpyridine semicarbazone as membrane carrier with dioctylphthalate as plasticizer and sodium tetraphenylborate (NaTBP) as anion excluder has been fabricated and investigated as Zn(II)-selective electrode. Best potential response is observed for the composition PVC 30%, plasticizer 58%, NaTBP 8% and ionophore 4% (w/w). The sensor showed a linear stable response over a concentration range of 1.0 × 10−2–4.56 × 10−6 M with a detection limit of 2.28 × 10−6 M and a response time <10 s. The electrode can be used for at least six months without any divergence in potential.


Sign in / Sign up

Export Citation Format

Share Document