scholarly journals Three-Dimensional Microwave Holographic Imaging Employing Forward-Scattered Waves Only

2013 ◽  
Vol 2013 ◽  
pp. 1-15 ◽  
Author(s):  
Reza K. Amineh ◽  
Maryam Ravan ◽  
Justin McCombe ◽  
Natalia K. Nikolova

We propose a three-dimensional microwave holographic imaging method based on the forward-scattered waves only. In the proposed method, one transmitter and multiple receivers perform together a two-dimensional scan on two planar apertures on opposite sides of the inspected domain. The ability to achieve three-dimensional imaging without back-scattered waves enables the imaging of high-loss objects, for example, tissues, where the back-scattered waves may not be available due to low signal-to-noise ratio or nonreciprocal measurement setup. The simulation and experimental results demonstrate the satisfactory performance of the proposed method in providing three-dimensional images. Resolution limits are derived and confirmed with simulation examples.

Author(s):  
W. Baumeister ◽  
R. Rachel ◽  
R. Guckenberger ◽  
R. Hegerl

IntroductionCorrelation averaging (CAV) is meanwhile an established technique in image processing of two-dimensional crystals /1,2/. The basic idea is to detect the real positions of unit cells in a crystalline array by means of correlation functions and to average them by real space superposition of the aligned motifs. The signal-to-noise ratio improves in proportion to the number of motifs included in the average. Unlike filtering in the Fourier domain, CAV corrects for lateral displacements of the unit cells; thus it avoids the loss of resolution entailed by these distortions in the conventional approach. Here we report on some variants of the method, aimed at retrieving a maximum of information from images with very low signal-to-noise ratios (low dose microscopy of unstained or lightly stained specimens) while keeping the procedure economical.


2015 ◽  
Vol 3 (1) ◽  
pp. SF15-SF20 ◽  
Author(s):  
Yunsong Huang ◽  
Dongliang Zhang ◽  
Gerard T. Schuster

We derived formulas for the tomographic resolution limits [Formula: see text] of diffraction data. Resolution limits exhibited that diffractions can provide twice or more the tomographic resolution of specular reflections and therefore led to more accurate reconstructions of velocities between layers. Numerical simulations supported this claim in which the tomogram inverted from diffraction data was noticeably more resolved compared to that inverted from specular data. The specular synthetics were generated by sources on the surface, and the diffraction data were generated by buried diffractors. However, this advantage is nullified if the intensity and signal-to-noise ratio of the diffractions are much less than those of the pervasive specular reflections.


2000 ◽  
Vol 6 (1) ◽  
pp. 68-75 ◽  
Author(s):  
Martin G. Wolkenstein ◽  
Herbert Hutter

This article proposes a lossy three-dimensional (3-D) image compression method for 3-D secondary ion microscopy (SIMS) image sets that uses a separable nonuniform 3-D wavelet transform. A typical 3-D SIMS measurement produces relatively large amounts of data which has to be reduced for archivation purposes. Although it is possible to compress an image set slice by slice, more efficient compression can be achieved by exploring the correlation between slices. Compared to different two-dimensional (2-D) image compression methods, compression ratios of the 3-D wavelet method are about four times higher at a comparable peak signal-to-noise ratio (PSNR).


2018 ◽  
Vol 53 (2) ◽  
pp. 245-259
Author(s):  
Gary S LeMay ◽  
Davood Askari

Out-of-autoclave materials have long been an established material system for secondary structural applications; however, recent advancements in material properties allow for more advanced structural applications. Even though certain out-of-autoclave properties have achieved parity with autoclaved cured materials, out-of-autoclave materials are cured at reduced temperatures and pressures resulting in less compaction and homogeneity. The consequence is extraneous ultrasonic signals, due to internal reflections and refractions that cause attenuation, potentially masking defects leading to unidentifiable indications. Advanced algorithms were developed to improve the signal to noise ratio between constituents of similar acoustic impedance in bonded out-of-autoclave carbon fiber reinforced polymer assemblies. Conventional ultrasonic nondestructive testing techniques and analysis software cannot consistently achieve signal to noise ratios that meet quantifiable rejection thresholds of accurately sized peel ply inserts at the bonded interface of composite assemblies. Ultrasonic pulse echo with full waveform capture was used to inspect a reference standard with peel ply inserts placed between the adhesive and three-dimensional-woven fabric preform. The ultrasonic signal was produced by a 64 element array transducer with a central frequency of 2.8 MHz. Waveform post-acquisition analysis with post processing software was used to analyze and enhance the signal response between the peel ply and the bondline resulting in the final algorithm. To verify the results, the signal to noise ratio of each insert was calculated for both the raw and processed data. As the measure of detectability, the method relies on principles of statistical measurement to provide an industry standard signal to noise response of 3:1.


2020 ◽  
Vol 10 (6) ◽  
pp. 1930
Author(s):  
Chengkun Fu ◽  
Huaibin Zheng ◽  
Gao Wang ◽  
Yu Zhou ◽  
Hui Chen ◽  
...  

Three-dimensional (3D) imaging under the condition of weak light and low signal-to-noise ratio is a challenging task. In this paper, a 3D imaging scheme based on time-correlated single-photon counting technology is proposed and demonstrated. The 3D imaging scheme, which is composed of a pulsed laser, a scanning mirror, single-photon detectors, and a time-correlated single-photon counting module, employs time-correlated single-photon counting technology for 3D LiDAR (Light Detection and Ranging). Aided by the range-gated technology, experiments show that the proposed scheme can image the object when the signal-to-noise ratio is decreased to −13 dB and improve the structural similarity index of imaging results by 10 times. Then we prove the proposed scheme can image the object in three dimensions with a lateral imaging resolution of 512 × 512 and an axial resolution of 4.2 mm in 6.7 s. At last, a high-resolution 3D reconstruction of an object is also achieved by using the photometric stereo algorithm.


2000 ◽  
Vol 6 (1) ◽  
pp. 68-75
Author(s):  
Martin G. Wolkenstein ◽  
Herbert Hutter

Abstract This article proposes a lossy three-dimensional (3-D) image compression method for 3-D secondary ion microscopy (SIMS) image sets that uses a separable nonuniform 3-D wavelet transform. A typical 3-D SIMS measurement produces relatively large amounts of data which has to be reduced for archivation purposes. Although it is possible to compress an image set slice by slice, more efficient compression can be achieved by exploring the correlation between slices. Compared to different two-dimensional (2-D) image compression methods, compression ratios of the 3-D wavelet method are about four times higher at a comparable peak signal-to-noise ratio (PSNR).


Sign in / Sign up

Export Citation Format

Share Document