scholarly journals Reliability of Subjective Pain Ratings and Nociceptive Flexion Reflex Responses as Measures of Conditioned Pain Modulation

2014 ◽  
Vol 19 (2) ◽  
pp. 93-96 ◽  
Author(s):  
Carlo Jurth ◽  
Benno Rehberg ◽  
Falk von Dincklage

BACKGROUND: The endogenous modulation of pain can be assessed through conditioned pain modulation (CPM), which can be quantified using subjective pain ratings or nociceptive flexion reflexes. However, to date, the test-retest reliability has only been investigated for subjective pain ratings.OBJECTIVE: To compare the test-retest reliability of CPM-induced changes, measured using subjective pain ratings and nociceptive flexion reflexes, to provide a reliable scoring parameter for future studies.METHOD: A total of 40 healthy volunteers each received painful electrical stimuli to the sural nerve to elicit nociceptive flexion reflexes. Reflex sizes and subjective pain ratings were recorded before and during the immersion of the contralateral hand in hot water to induce CPM as well as innocuous water as control. Measurements were repeated in a retest 28 days later.RESULTS: Intraclass correlation coefficients showed good test-retest reliabilities of CPM during the hot water stimulus for both scoring parameters. Subjective pain ratings also correlated between test and retest during the control stimulus.CONCLUSIONS: Subjective pain ratings and nociceptive flexion reflexes show comparable test-retest reliabilities, but they reflect different components of CPM. While subjective pain ratings appear to incorporate cognitive influences to a larger degree, reflex responses appear to reflect spinal nociception more purely.

2020 ◽  
pp. 153944922096107
Author(s):  
Ecem Karanfil ◽  
Yeliz Salcı ◽  
Ayla Fil-Balkan ◽  
Can Ebru Bekircan-Kurt ◽  
Sevim Erdem Özdamar ◽  
...  

Linguistic, reliable, and valid secondary efficacy measures are important in clinical settings and studies. The aim of the study is to report test–retest reliability and construct validity of Turkish version of Myasthenia Gravis-Activities of Daily Living Scale (MG-ADL-T) in Myasthenia Gravis (MG) patients. Fifty-two ocular and generalized individuals with MG, applying to rehabilitation center, were included in the study. MG-ADL-T, MG quality-of-life questionnaire (MG-QoL), MG composite (MGC), quantitative MG score (QMGS), and pulmonary function test were administered. Reliability was assessed with intraclass correlation coefficient (ICC) and Cronbach’s alpha. Spearman correlation test and receiver operating characteristic (ROC) analysis were performed for construct validity. MG-ADL-T had fair internal consistency (Cronbach’s α = .67), excellent test–retest reliability (ICC = 0.96) and moderate construct validity (MG-QoL, r = 0.59; QMGS, r = .58; MGC, r = .68). MG-ADL, a unique scale that evaluates activities of daily living (ADL), has good test–retest reliability and construct validity in Turkish MG patients.


Sports ◽  
2020 ◽  
Vol 8 (9) ◽  
pp. 117
Author(s):  
Mike Climstein ◽  
Jessica L. Alder ◽  
Alyce M. Brooker ◽  
Elissa J. Cartwright ◽  
Kevin Kemp-Smith ◽  
...  

Background: Usage of wrist-worn activity monitors has rapidly increased in recent years, and these devices are being used by both fitness enthusiasts and in clinical populations. We, therefore, assessed the test–retest reliability of the Polar Vantage M (PVM) watch when measuring heart rate (HR) during various treadmill exercise intensities. Methods: HR was measured every 30 s (simultaneous electrocardiography (ECG) and PVM). Test–retest reliability was determined using an intraclass correlation coefficient (ICC) with 95% confidence intervals (CIs). Standard error of measurement (SEM) and smallest real difference (SRD) were used to determine measurement variability. Results: A total of 29 participants completed the trials. ICC values for PVM during stages 1, 2 and 5 demonstrated good to excellent test–retest reliability (0.78, 0.78 and 0.92; 95% CI (0.54–0.90, 0.54–0.9, 0.79–0.97)). For PVM during stages 0 (rest), 3 and 4, the ICC values indicated poor to good reliability (0.42, 0.68 and 0.58; 95% CI (−0.27–0.73, 0.32–0.85, 0.14–0.80)). Conclusion: This study identified that the test–retest reliability of the PVM was comparable at low and high exercise intensities; however, it revealed a poor to good test–retest reliability at moderate intensities. The PVM should not be used in a clinical setting where monitoring of an accurate HR is crucial to the patients’ safety.


2010 ◽  
Vol 7 (5) ◽  
pp. 671-676 ◽  
Author(s):  
Suzie Mudge ◽  
Denise Taylor ◽  
Oliver Chang ◽  
Rosita Wong

Background:Activity Monitors give an objective measure of usual walking performance. This study aimed to examine the test-retest reliability of the StepWatch Activity Monitor outputs (mean steps/day; peak activity index; sustained activity indices of 1, 5, 20, 30, 60 minutes; steps at high, medium, and low stepping rates).Methods:Thirty healthy adults age 18 to 49 years wore the StepWatch for 2 3-day periods at least 1 week apart.Results:The intraclass correlation coefficients of the StepWatch outputs ranged from 0.44 to 0.91 over 3 days. The coefficient of variation ranged from 3.0% to 51.3% over the monitoring periods, with higher variation shown for shorter monitoring periods. The most reliable 5 outputs had 95% limits of agreement between 3-day periods that were less than 40%. These were mean steps/day (±39.1%), highest step rate in 1 (±17.3%) and 5 (±37.4%) minutes, peak activity index (±25.6%), and percentage of inactive time (±9.52%).Conclusions:Mean steps/day, highest step rate in 1 and 5 minutes, peak activity index, and percentage of inactive time have good test-retest reliability over a 3-day monitoring period, with lower reliability shown by the other StepWatch outputs. Monitoring over 1 or 2 days is less reliable.


2013 ◽  
Vol 48 (3) ◽  
pp. 331-336 ◽  
Author(s):  
Rebecca Shultz ◽  
Scott C. Anderson ◽  
Gordon O. Matheson ◽  
Brandon Marcello ◽  
Thor Besier

Context: The Functional Movement Screen (FMS) is a popular test to evaluate the degree of painful, dysfunctional, and asymmetric movement patterns. Despite great interest in the FMS, test-retest reliability data have not been published. Objective: To assess the test-retest and interrater reliability of the FMS and to compare the scoring by 1 rater during a live session and the same session on video. Design: Cross-sectional study. Setting: Human performance laboratory in the sports medicine center. Patients or Other Participants: A total of 21 female (age = 19.6 ± 1.5 years, height = 1.7 ± 0.1 m, mass = 64.4 ± 5.1 kg) and 18 male (age = 19.7 ± 1.0 years, height = 1.9 ± 0.1 m, mass = 80.1 ± 9.9 kg) National Collegiate Athletic Association Division IA varsity athletes volunteered. Intervention(s): Each athlete was tested and retested 1 week later by the same rater who also scored the athlete's first session from a video recording. Five other raters scored the video from the first session. Main Outcome Measure(s): The Krippendorff α (K α) was used to assess the interrater reliability, whereas intraclass correlation coefficients (ICCs) were used to assess the test-retest reliability and reliability of live-versus-video scoring. Results: Good reliability was found for the test-retest (ICC = 0.6), and excellent reliability was found for the live-versus-video sessions (ICC = 0.92). Poor reliability was found for the interrater reliability (K α = .38). Conclusions: The good test-retest and high live-versus-video session reliability show that the FMS is a usable tool within 1 rater. However, the low interrater K α values suggest that the FMS within the limits of generalization should not be used indiscriminately to detect deficiencies that place the athlete at greater risk for injury. The FMS interrater reliability may be improved with better training for the rater.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
En-Chi Chiu ◽  
Ya-Chen Lee ◽  
Shu-Chun Lee ◽  
I-Ping Hsueh

Abstract Background The Performance-based measure of Executive Functions (PEF) with four domains is designed to assess executive functions in people with schizophrenia. The purpose of this study was to examine the test-retest reliability of the PEF administered by the same rater (intra-rater agreement) and by different raters (inter-rater agreement) in people with schizophrenia and to estimate the values of minimal detectable change (MDC) and MDC%. Methods Two convenience samples (each sample, n = 60) with schizophrenia were conducted two assessments (two weeks apart). The intraclass correlation coefficient (ICC) was analyzed to examine intra-rater and inter-rater agreements of the test-retest reliability of the PEF. The MDC was calculated through standard error of measurement. Results For the intra-rater agreement study, the ICC values of the four domains were 0.88–0.92. The MDC (MDC%) of the four domains (volition, planning, purposive action, and perfromance effective) were 13.0 (13.0%), 12.2 (16.4%), 16.2 (16.2%), and 16.3 (18.8%), respectively. For the inter-rater agreement study, the ICC values of the four domains were 0.82–0.89. The MDC (MDC%) were 15.8 (15.8%), 17.4 (20.0%), 20.9 (20.9%), and 18.6 (18.6%) for the volition, planning, purposive action, and performance effective domains, respectively. Conclusions The PEF has good test-retest reliability, including intra-rater and inter-rater agreements, for people with schizophrenia. Clinicians and researchers can use the MDC values to verify whether an individual with schizophrenia shows any real change (improvement or deterioration) between repeated PEF assessments by the same or different raters.


Author(s):  
Chen-Chi Wang ◽  
Jia-Shiou Liao ◽  
Hsiu-Chin Lai ◽  
Yi-Hsuan Lo

Purpose The Voice Handicap Index (VHI) questionnaire assesses the impact of total laryngectomy on voice-related quality of life. This study evaluates the Mandarin VHI, including its internal consistency, test–retest reliability, content validity, and differences in scores for Mandarin alaryngeal patients with pneumatic artificial laryngeal (PA) and esophageal (ES) speech. Method Translation and validation of the VHI questionnaire was performed through the forward–backward translation technique. This study used a sample of 78 PA and 23 ES participants from Taiwan who completed the Mandarin VHI. Forty-two of the alaryngeal participants completed the Mandarin VHI twice over a period of 7–63 days. Results The measurement of the internal consistency of the Mandarin VHI showed a high Cronbach's alpha coefficient for the total score (.975) and the functional (.930), physical (.939), and emotional (.938) subscales. Based on the results of the intraclass correlation coefficients, good test–retest reliability for the total and domain scores was found (intraclass correlation coefficient = .827–.863). Conclusion The Mandarin VHI was validated as an instrument with proper internal consistency and reliability, which supports the Mandarin VHI as a valid instrument for the self-evaluation of handicaps related to voice problems in PA and ES speakers.


2014 ◽  
Vol 114 (1) ◽  
pp. 93-103 ◽  
Author(s):  
Tomas Larson ◽  
Eva Norén Selinus ◽  
Clara Hellner Gumpert ◽  
Thomas Nilsson ◽  
Nóra Kerekes ◽  
...  

The Autism-Tics, AD/HD, and other Comorbidities (A–TAC) inventory is used in epidemiological research to assess neurodevelopmental problems and coexisting conditions. Although the A–TAC has been applied in various populations, data on retest reliability are limited. The objective of the present study was to present additional reliability data. The A–TAC was administered by lay assessors and was completed on two occasions by parents of 400 individual twins, with an average interval of 70 days between test sessions. Intra- and inter-rater reliability were analysed with intraclass correlations and Cohen's κ. A–TAC showed excellent test-retest intraclass correlations for both autism spectrum disorder and attention deficit hyperactivity disorder (each at .84). Most modules in the A–TAC had intra- and inter-rater reliability intraclass correlation coefficients of ≥ .60. Cohen's κ indicated acceptable reliability. The current study provides statistical evidence that the A–TAC yields good test-retest reliability in a population-based cohort of children.


2019 ◽  
Vol 6 (1) ◽  
pp. 32-45 ◽  
Author(s):  
Axel Georg Meender Schäfer ◽  
Britta Sebelin ◽  
Lena Spitzer

Abstract Diagnostic ability is essential for expert professional practice. Several instruments have been developed to assess diagnostic skills independent of specific knowledge. One such instrument is the diagnostic thinking inventory (DTI), which is used in different settings to evaluate diagnostic performance and has shown acceptable reliability and validity. The aim of the present study was to translate and validate a German version (DTI-G). Cultural adaptation and translation were performed according to international guidelines. Internal consistency and item discrimination indexes were calculated. The factorial structure of the DTI-G, test-retest reliability and known-groups validity were tested. A total of 388 physiotherapists completed the questionnaire. The internal consistency was good for the overall score of the DTI-G (Cronbach’s a = 0.84). Exploratory factor analysis yielded a five-factor solution with 21 items that explained 55% of the total variance across items. A confirmatory principal component analysis resulted in the same five-factor structure, showing an acceptable to good overall fit of the model (CFI = 0.93; RMSEA = 0.05; SRMR = 0.06). Test-retest reliability was found to be good (intraclass correlation coefficient ICC2,1 = 0.87, p < 0.001, n = 118). The difference between participants with more than 9 years of clinical experience and those with less than 9 years of clinical experience (median split) was significant (t385 = 6.00, p < 0.001), supporting known-groups validity. The results support construct validity and indicate good test-retest reliability of the DTI-G. The DTI-G can be used to measure and develop diagnostic ability of physiotherapists in clinical practice and education. Further research is necessary to validate the questionnaire for other health professions.


Sign in / Sign up

Export Citation Format

Share Document