scholarly journals Radiological Imaging for Assessing the Respectability of Hilar Cholangiocarcinoma: A Systematic Review and Meta-Analysis

2015 ◽  
Vol 2015 ◽  
pp. 1-11 ◽  
Author(s):  
Hongchen Zhang ◽  
Jian Zhu ◽  
Fayong Ke ◽  
Mingzhe Weng ◽  
Xiangsong Wu ◽  
...  

Hilar cholangiocarcinoma (HCC) remains one of the most difficult tumors to stage and treat. The aim of the study was to assess the diagnostic efficiency of computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography/computer tomography (PET/CT) in evaluating the resectability of HCC. A systematic search was performed of the PubMed, EMBASE, and Cochrane databases. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated for individual studies and pooled data as well as test for heterogeneity and public bias. Our data showed that CT had the highest pooled sensitivity at 95% (95% CI: 91–97), whereas PET/CT had the highest pooled specificity at 81% (95% CI: 69–90). The area under the curve (AUC) of CT, MRI, and PET/CT was 0.9269, 0.9194, and 0.9218, respectively. In conclusion, CT is the most frequently used imaging modality to assess HCC resectability with a good sensitivity and specificity. MRI was generally comparable with that of CT and can be used as an alternative imaging technique. PET/CT appears to be the best technique in detecting lymph node and distant metastasis in HCC but has no clear role in helping to evaluate issues of local resectability.

2019 ◽  
Vol 12 (3) ◽  
pp. 220-228 ◽  
Author(s):  
Laura Evangelista ◽  
Lea Cuppari ◽  
Luisa Bellu ◽  
Daniele Bertin ◽  
Mario Caccese ◽  
...  

Purpose: The aims of the present study were to: 1- critically assess the utility of L-3,4- dihydroxy-6-18Ffluoro-phenyl-alanine (18F-DOPA) and O-(2-18F-fluoroethyl)-L-tyrosine (18F-FET) Positron Emission Tomography (PET)/Computed Tomography (CT) in patients with high grade glioma (HGG) and 2- describe the results of 18F-DOPA and 18F-FET PET/CT in a case series of patients with recurrent HGG. Methods: We searched for studies using the following databases: PubMed, Web of Science and Scopus. The search terms were: glioma OR brain neoplasm and DOPA OR DOPA PET OR DOPA PET/CT and FET OR FET PET OR FET PET/CT. From a mono-institutional database, we retrospectively analyzed the 18F-DOPA and 18F-FET PET/CT of 29 patients (age: 56 ± 12 years) with suspicious for recurrent HGG. All patients underwent 18F-DOPA or 18F-FET PET/CT for a multidisciplinary decision. The final definition of recurrence was made by magnetic resonance imaging (MRI) and/or multidisciplinary decision, mainly based on the clinical data. Results: Fifty-one articles were found, of which 49 were discarded, therefore 2 studies were finally selected. In both the studies, 18F-DOPA and 18F-FET as exchangeable in clinical practice particularly for HGG patients. From our institutional experience, in 29 patients, we found that sensitivity, specificity and accuracy of 18F-DOPA PET/CT in HGG were 100% (95% confidence interval- 95%CI - 81-100%), 63% (95%CI: 39-82%) and 62% (95%CI: 39-81%), respectively. 18F-FET PET/CT was true positive in 4 and true negative in 4 patients. Sensitivity, specificity and accuracy for 18F-FET PET/CT in HGG were 100%. Conclusion: 18F-DOPA and 18F-FET PET/CT have a similar diagnostic accuracy in patients with recurrent HGG. However, 18F-DOPA PET/CT could be affected by inflammation conditions (false positive) that can alter the final results. Large comparative trials are warranted in order to better understand the utility of 18F-DOPA or 18F-FET PET/CT in patients with HGG.


2016 ◽  
Vol 39 (2) ◽  
pp. 467-480 ◽  
Author(s):  
Junzhong Liu ◽  
Zhongfeng Chen ◽  
Tianyu Wang ◽  
Li Liu ◽  
Lei Zhao ◽  
...  

Background/Aims: To date, several positron emission tomography/computed tomography (PET/CT) radiotracers including fluorine-18 fluorodeoxyglucose (18F-FDG), carbon-11 labeled choline (11C-choline), 18-F fluorocholine (18F-FCH) and carbon-11 acetate (11C-acetate) have already been assessed in the application of prostate cancer (PCa) diagnosis to some extent, the diagnostic efficiency of these radiotracers still remain controversial. As a result of this, we carried out this meta-analysis for the purpose of comparing the diagnostic accuracy among four PET/CT radiotracers. Methods: A systematical literature search for articles was performed until July 3, 2015. We implemented all analysis using the statistical software of STATA12 and quality assessment was performed using QUADAS-2. Results: A total of 56 studies containing 3,586 patients were included in this meta-analysis. Parameter estimates of the overall analysis are as follows: sensitivity, 0.80 (95% CI: 0.74-0.85); specificity, 0.84 (95% CI: 0.77-0.89) and area under roc curve-AUC of SROC, 0.89 (95% CI: 0.86-0.91), indicating a relatively high level of accuracy in diagnosis of PCa. When different radiotracers of PET/CT were compared, 18F-FCH-PET/CT was ranked as the most favorable with the highest value of AUC (AUC = 0.94; 95% CI: 0.92-0.96) whereas 18F-FDG was the least favorable (AUC = 0.73, 95% CI: 0.69-0.77). Conclusion: This study suggested that PET/CT imaging plays an invaluable role in the diagnosis of PCa and 18F-FCH-PET/CT was considered as a superior diagnostic tool over other radiotracers. More attention should be paid to the diagnostic efficiency of the four radiotracers particularly for PCa patients with different clinical stages.


2008 ◽  
Vol 18 (6) ◽  
pp. 1332-1338 ◽  
Author(s):  
J.-Y. Park ◽  
E. N. Kim ◽  
D.-Y. Kim ◽  
J.-H. Kim ◽  
Y.-M. Kim ◽  
...  

The objective of this study was to evaluate the validity and clinical impact of positron emission tomography (PET) or positron emission tomography/computed tomography (PET/CT) using 18-fluoro-2-deoxy-D-glucose in the posttherapy surveillance of patients with endometrial carcinoma. Eighty-eight patients previously treated for histopathologically diagnosed endometrial adenocarcinoma underwent 99 PET or PET/CT scans at follow-up visits at Asan Medical Center, Seoul, Korea, between 2001 and 2007. The standard of reference for tumor recurrence consisted of histopathologic confirmation or follow-up information at least 6 months after PET or PET/CT. Of the 88 patients, 24 underwent PET (n= 11) and/or PET/CT (n= 14) scans due to suspected disease recurrence. The sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of PET and/or PET/CT in detecting recurrence in these patients were 100%, 83.3%, 96%, 95%, and 100%, respectively. Especially, PET/CT revealed true-positive findings in three patients with elevated tumor markers but negative CT findings. The remaining 64 patients underwent PET (n= 8) and/or PET/CT (n= 66) as part of routine posttherapy surveillance; these patients were asymptomatic, with no evidence of disease. The sensitivity, specificity, accuracy, PPV, and NPV of PET and/or PET/CT in detecting recurrence in these patients were all 100%. Clinical decisions on treatment were changed in 14 (21.9%) patients by introducing PET or PET/CT into their conventional posttherapy surveillance program. PET and/or PET/CT were highly effective in discriminating true recurrence in patients with suspected recurrence, highly sensitive in detecting recurrence in asymptomatic patients, and had impacts on clinical decisions in a considerable portion of patients.


Medicina ◽  
2021 ◽  
Vol 57 (6) ◽  
pp. 561
Author(s):  
Michela Massollo ◽  
Francesco Fiz ◽  
Gianluca Bottoni ◽  
Martina Ugolini ◽  
Francesco Paparo ◽  
...  

Background and Objectives: 18F-fluorodeoxyglucose (FDG) positron emission tomography/X-ray computed tomography (PET/CT) represents the mainstay diagnostic procedure for suspected ovarian cancer (OC) recurrence. PET/CT can be integrated with contrast medium and in various diagnostic settings; however, the effective benefit of this procedure is still debated. We aimed to compare the diagnostic capabilities of low-dose and contrast-enhanced PET/CT (PET/ldCT and PET/ceCT) in patients with suspected ovarian cancer relapse. Materials and Methods: 122 OC patients underwent both PET/ldCT and PET/ceCT. Two groups of nuclear medicine physicians and radiologists scored the findings as positive or negative. Clinical/radiological follow-up was used as ground truth. Sensitivity, specificity, negative/positive predictive value, and accuracy were calculated at the patient and the lesion level. Results: A total of 455 and 474 lesions were identified at PET/ldCT and PET/ceCT, respectively. At the lesion level, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were not significantly different between PET/ldCT and PET/ceCT (98%, 93.3%, 97.4%, 94.9%, and 96.9% for PET/ldCT; 99%, 95.5%, 98.3%, 97%, and 98% for PET/ceCT, p = ns). At the patient level, no significant differences in these parameters were identified (e.g., p = 0.22 and p = 0.35 for accuracy, in the peritoneum and lymph nodes, respectively). Smaller peritoneal/lymph node lesions close to physiological FDG uptake sources were found in the cases of misidentification by PET/ldCT. PET/ceCT prompted a change in clinical management in four cases (3.2%) compared to PET/ldCT. Conclusions: PET/ceCT does not perform better than PET/ldCT but can occasionally clarify doubtful peritoneal findings on PET/ldCT. To avoid unnecessary dose to the patient, PET/ceCT should be excluded in selected cases.


2005 ◽  
Vol 48 (spe2) ◽  
pp. 179-183 ◽  
Author(s):  
Francisco Lomeña ◽  
Marina Soler

Positron emission tomography (PET) is an imaging modality that gives information on tissue metabolism and functionalism, different from other imaging techniques like computed tomography (CT) and magnetic resonance imaging (MRI), which provide anatomical or structural information. PET has reached its development in biomedical research because of its capacity to use analogous compounds of many endogenous substance as tracers, and to measure, in vivo and in a non-invasive way, their consumption by the different organs and tissues of the mammalian body. Fluordeoxyglucose-F18 (FDG) PET has been proven to be a tracer adequate for clinical use in oncology and in many neurological diseases, with an excellent cost-efficiency ratio. The current PET-CT scanners can come to be the best tools for exploring patients who suffer from cancer.


2011 ◽  
Vol 14 (5) ◽  
pp. 283 ◽  
Author(s):  
Andre Plass ◽  
Maximilian Y. Emmert ◽  
Oliver Gaemperli ◽  
Hatem Alkadhi ◽  
Philipp Kaufmann ◽  
...  

<p><b>Background:</b> We evaluated how comprehensive assessment of coronary artery lesions and their hemodynamic relevance by means of hybrid positron emission tomography (PET) and computed tomography (CT) imaging would affect decision-making in coronary artery bypass surgery (CABG), compared with using invasive coronary angiography (ICA) alone.</p><p><b>Methods:</b> After undergoing ICA, 27 patients (21 men and 6 women; mean SD age, 66 � 10 years) planned for cardiac surgery were scheduled for myocardial perfusion stress/rest evaluation with [13N]ammonia PET and CT coronary angiography. Only ICA was available to the surgeon. Postoperatively, the performed CABG was compared with the hypothetical strategy based on hybrid PET/CT findings (regional coronary flow reserve [CFR], myocardial perfusion defects). Procedures included CABG (n = 18) alone, CABG combined with valve replacement (n = 6), and CABG combined with isolated valve replacement (n = 3). A total of 56 bypass grafts (28 venous and 28 arterial) and 66 distal anastomoses were placed.</p><p><b>Results:</b> CT evaluation showed 93% concordance (66/71) with ICA regarding significant stenoses, with sensitivity, specificity, positive predictive value, and negative predictive value of 93.1%, 98.7%, 94.4%, and 98.4%, respectively. In the PET scan, 16 patients had 1 ischemic region, and 12 patients had 1 scar region, including 5 patients who presented with mixed conditions (scar and ischemia). One patient had a completely normal myocardium. Compared with the performed surgery, PET/CT fusion evaluation showed that of the performed anastomoses, 48% had documented ischemia (with a CFR <2 in 86%), 38% were nonischemic (although a CFR value <2 was found in 78%), and 14% had scar tissue (fixed perfusion defect).</p><p><b>Conclusions:</b> Although <50% of bypasses were placed to areas with myocardial ischemia, the CFR was low in the majority of nonischemic regions, a finding that may have important prognostic relevance. PET/CT fusion imaging could potentially influence planning for CABG and provide incremental prognostic information.</p>


2018 ◽  
Vol 1 ◽  
pp. 9
Author(s):  
Harshad Arvind Vanjare ◽  
Jyoti Panwar

Objective The objective of the study was to assess the accuracy of ultrasound examination for the diagnosis of rotator cuff tear and tendinosis performed by a short experienced operator, compared to magnetic resonance imaging (MRI) results. Method A total of 70 subjects suspected to have rotator cuff tear or tendinosis and planned for shoulder MRI were included in the study. Shoulder ultrasound was performed either before or after the MRI scan on the same day. Ultrasound operator had a short experience in performing an ultrasound of the shoulder. Ultrasound findings were correlated to MRI findings. Results Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for the diagnosis of tendinosis were 58%, 84%, 63%, 80%, and 75%, respectively, and it was 68%, 91%, 73%, 88%, and 85%, respectively, for the diagnosis of rotator cuff tear. Conclusions Sensitivity for diagnosing rotator cuff tear or tendinosis was moderate but had a higher negative predictive value. Thus, the ultrasound operator with a short experience in performing shoulder ultrasound had moderate sensitivity in diagnosing tendinosis or tears; however, could exclude them with confidence.


2020 ◽  
Vol 163 (6) ◽  
pp. 1156-1165
Author(s):  
Juan Xiao ◽  
Qiang Xiao ◽  
Wei Cong ◽  
Ting Li ◽  
Shouluan Ding ◽  
...  

Objective To develop an easy-to-use nomogram for discrimination of malignant thyroid nodules and to compare diagnostic efficiency with the Kwak and American College of Radiology (ACR) Thyroid Imaging, Reporting and Data System (TI-RADS). Study Design Retrospective diagnostic study. Setting The Second Hospital of Shandong University. Subjects and Methods From March 2017 to April 2019, 792 patients with 1940 thyroid nodules were included into the training set; from May 2019 to December 2019, 174 patients with 389 nodules were included into the validation set. Multivariable logistic regression model was used to develop a nomogram for discriminating malignant nodules. To compare the diagnostic performance of the nomogram with the Kwak and ACR TI-RADS, the area under the receiver operating characteristic curve, sensitivity, specificity, and positive and negative predictive values were calculated. Results The nomogram consisted of 7 factors: composition, orientation, echogenicity, border, margin, extrathyroidal extension, and calcification. In the training set, for all nodules, the area under the curve (AUC) for the nomogram was 0.844, which was higher than the Kwak TI-RADS (0.826, P = .008) and the ACR TI-RADS (0.810, P < .001). For the 822 nodules >1 cm, the AUC of the nomogram was 0.891, which was higher than the Kwak TI-RADS (0.852, P < .001) and the ACR TI-RADS (0.853, P < .001). In the validation set, the AUC of the nomogram was also higher than the Kwak and ACR TI-RADS ( P < .05), each in the whole series and separately for nodules >1 or ≤1 cm. Conclusions When compared with the Kwak and ACR TI-RADS, the nomogram had a better performance in discriminating malignant thyroid nodules.


2021 ◽  
Vol 20 ◽  
pp. 153303382110119
Author(s):  
Wen-Ting Zhang ◽  
Guo-Xun Zhang ◽  
Shuai-Shuai Gao

Background: Leukemia is a common malignant disease in the human blood system. Many researchers have proposed circulating microRNAs as biomarkers for the diagnosis of leukemia. We conducted a meta-analysis to evaluate the diagnostic accuracy of circulating miRNAs in the diagnosis of leukemia. Methods: A comprehensive literature search (updated to October 13, 2020) in PubMed, EMBASE, Web of Science, Cochrane Library, Wanfang database and China National Knowledge Infrastructure (CNKI) was performed to identify eligible studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) for diagnosing leukemia were pooled for both overall and subgroup analysis. The meta-regression and subgroup analysis were performed to explore heterogeneity and Deeks’ funnel plot was used to assess publication bias. Results: 49 studies from 22 publications with a total of 3,489 leukemia patients and 2,756 healthy controls were included in this meta-analysis. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under the curve were 0.83, 0.92, 10.8, 0.18, 59 and 0.94, respectively. Subgroup analysis shows that the microRNA clusters of plasma type could carry out a better diagnostic accuracy of leukemia patients. In addition, publication bias was not found. Conclusions: Circulating microRNAs can be used as a promising noninvasive biomarker in the early diagnosis of leukemia.


Diagnostics ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 720
Author(s):  
Valentin Pretet ◽  
Cyrille Blondet ◽  
Yvon Ruch ◽  
Matias Martinez ◽  
Soraya El Ghannudi ◽  
...  

According to European Society of Cardiology guidelines (ESC2015) for infective endocarditis (IE) management, modified Duke criteria (mDC) are implemented with a degree of clinical suspicion degree, leading to grades such as “possible” or “rejected” IE despite a persisting high level of clinical suspicion. Herein, we evaluate the 18F-FDG PET/CT diagnostic and therapeutic impact in IE suspicion, with emphasis on possible/rejected IE with a high clinical suspicion. Excluding cases of definite IE diagnosis, 53 patients who underwent 18F-FDG PET/CT for IE suspicion were selected and afterwards classified according to both mDC (possible IE/Duke 1, rejected IE/Duke 0) and clinical suspicion degree (high and low IE suspicion). The final status regarding IE diagnosis (gold standard) was based on the multidisciplinary decision of the Endocarditis Team, including the ‘imaging specialist’. PET/CT images of the cardiac area were qualitatively interpreted and the intensity of each focus of extra-physiologic 18F-FDG uptake was evaluated by a maximum standardized uptake value (SUVmax) measurement. Extra-cardiac 18F-FDG PET/CT pathological findings were considered to be a possible embolic event, a possible source of IE, or even a concomitant infection. Based on the Endocarditis Team consensus, final diagnosis of IE was retained in 19 (36%) patients and excluded in 34 (64%). With a sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and global accuracy of 79%, 100%, 100%, 89%, and 92%, respectively, PET/CT performed significantly better than mDC (p = 0.003), clinical suspicion degree (p = 0.001), and a combination of both (p = 0.001) for IE diagnosis. In 41 patients with possible/rejected IE but high clinical suspicion, sensitivity, specificity, PPV, NPV, and global accuracies were 78%, 100%, 100%, 85%, and 90%, respectively. Moreover, PET/CT contributed to patient management in 24 out of 53 (45%) cases. 18F-FDG PET/CT represents a valuable diagnostic tool that could be proposed for challenging IE cases with significant differences between mDC and clinical suspicion degree. 18F-FDG PET/CT allows a binary diagnosis (definite or rejected IE) by removing uncertain diagnostic situations, thus improving patient therapeutic management.


Sign in / Sign up

Export Citation Format

Share Document