scholarly journals Evaluation of the Lower Punctum Parameters and Morphology Using Spectral Domain Anterior Segment Optical Coherence Tomography

2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Riham S. H. M. Allam ◽  
Rania A. Ahmed

Purpose. To study features of the lower punctum in normal subjects using spectral domain anterior segment optical coherence tomography (SD AS-OCT).Methods. Observational cross-sectional study that included 147 punctae (76 subjects). Punctae were evaluated clinically for appearance, position, and size. AS-OCT was used to evaluate the punctal shape, contents, and junction with the vertical canaliculus. Inner and outer diameters as well as depth were measured.Results. 24 males and 52 females (mean age44±14.35 y) were included. Lower punctum was perceived by OCT to be an area with an outer diameter (mean412.16±163 μm), inner diameter (mean233.67±138.73 μm), and depth (mean251.7±126.58 μm). The OCT measured outer punctum diameter was significantly less than that measured clinically (P: 0.000). Seven major shapes were identified. The junction with the vertical canaliculus was detectable in 44%. Fluid was detected in 34%, one of which had an air bubble; however, 63% of punctae showed no contents and 4% had debris.Conclusions. AS-OCT can be a useful tool in understanding the anatomy of the punctum and distal lacrimal system as well as tear drainage physiology. Measuring the punctum size may play a role in plugs fitting.

2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Naresh Babu Kannan ◽  
Sagnik Sen ◽  
Prithviraj Udaya ◽  
Obuli Ramachandran ◽  
Kim Ramasamy

Purpose. To study the clinicodemographic profile of dome-shaped maculopathy (DSM) eyes in the Indian population and characterization using spectral-domain optical coherence tomography (SD-OCT). Methods. This observational cross-sectional study included 25 eyes of 14 patients diagnosed with DSM. All eyes underwent SD-OCT for characterization of the dome profile and also to measure central macular thickness (CMT), subfoveal choroidal thickness (SFCT), and dome height (DH) and to detect the presence of subretinal fluid (SRF). Results. The mean age of patients was 48.36 ± 14.23 years (range, 28–65 years). Eleven patients had bilateral involvement. Mean axial length of all eyes was 24.25 ± 1.95 mm and mean spherical equivalent −4.23 ± 3.79 DS. Overall, 11/25 eyes (44%) had round domes, 9/25 eyes (36%) had horizontal domes, and 5/25 eyes (20%) had vertical domes, with a mean dome height at fovea of 500.54 ± 291.58 µm. Vertical domes had higher DH compared to horizontal or combined domes p = 0.02 . Six eyes (6/25, 24%) showed the presence of SRF; 60% of vertical domes had SRF, and 22.2% of horizontal domes had SRF. The eyes having SRF had significantly higher CMT p = 0.017 and DH p = 0.001 , especially in horizontal domes p = 0.023 . The eyes with thicker SFCT tended to have higher DH and poorer visual acuity. Conclusion. Indian DSM eyes may have relatively lesser amounts of myopia. Choroidal thickening may play a role in development of DSM and may also be related to development of subretinal fluid in such eyes.


2020 ◽  
Vol 33 (5) ◽  
pp. 318 ◽  
Author(s):  
Mariana Almeida Oliveira ◽  
Andreia Rosa ◽  
Mário Soares ◽  
João Gil ◽  
Esmeralda Costa ◽  
...  

Introduction: Infectious keratitis is an important cause of visual loss. The purpose of this study was to investigate anterior segment optical coherence tomography patterns in infectious keratitis and evaluate the role of this tool in the early management of this disorder.Material and Methods: In this cross-sectional study, we included patients with proven infectious keratitis, either by culture or therapeutic trial. Subjects underwent baseline anterior segment optical coherence tomography (Spectralis® anterior segment module, Heidelberg Engineering, Germany) performed by the same operator. We used anterior segment optical coherence tomography vertical and horizontal raster default scans with 6.0 mm scan lines.Results: Twenty-five patients (14 men and 11 women) were included. The most common risk factors identified were ocular trauma (11 cases) and contact lens wear (7 cases). Fifteen patients presented bacterial infection; three, fungal infection; two parasitic infection; and five cases presented a negative microbiological culture. Anterior segment optical coherence tomography depicted nine distinct morphological patterns.Discussion: Anterior segment optical coherence tomography allows the depth of corneal involvement to be assessed. When the only patterns identified were hyperreflective stromal lesion and stromal edema, the visual outcome was better. Cystic spaces were present in severe bacterial keratitis.Conclusion: Anterior segment optical coherence tomography can complement biomicroscopy, allowing for a better characterization of corneal involvement at presentation that can help in staging and providing useful prognostic information.


2021 ◽  
Vol 13 ◽  
pp. 251584142110201
Author(s):  
Anuradha Raj ◽  
Renu Dhasmana ◽  
Harsh Bahadur

Purpose: To evaluate the relationship between measurements and various morphometric parameters of primary pterygium on anterior segment optical coherence tomography(AS-OCT) and refractive and keratometric astigmatism. Methods: In this cross-sectional study, patients with primary pterygium were included. The AS-OCT parameters of pterygium consisting of epithelial thickness near apex(µm), apical or head thickness(µm), its thickness at limbus(µm), horizontal length of pterygium(mm), central corneal thickness (µm) and maximum pterygium thickness(mm) were evaluated. Results: Sixty three patients comprising of 63 eyes with a primary pterygium were studied. The mean keratometric and refractive astigmatism were 1.69 ± 3.15 Diopter(D) and0.5 ± 1.4D, respectively. There was a significant association between pterygium grade and stocker’s line with keratometric astigmatism ( p = 0.02, 0.00) respectively. Vertical and horizontal length on slit lamp and horizontal length on AS-OCT showed significant association with keratometric astigmatism ( p = 0.05, 0.00,0.00), respectively. Limbal thickness on AS-OCT showed significant positive correlation with refractive astigmatism ( r = 0.29, p = 0.02). Conclusion: The pterygium grade influences the keratometric astigmatism. Increased limbal thickness of pterygium on AS-OCT leads to more refractive astigmatism.


2019 ◽  
Vol 104 (6) ◽  
pp. 795-799 ◽  
Author(s):  
Natalia Porporato ◽  
Mani Baskaran ◽  
Tin A Tun ◽  
Rehena Sultana ◽  
Marcus Tan ◽  
...  

Background/aimsAlthough being a more objective tool for assessment and follow-up of angle closure, reliability studies have reported a moderate diagnostic performance for anterior segment optical coherence tomography (OCT) technologies when comparing with gonioscopy as the reference standard. We aim to determine factors associated with diagnostic disagreement in angle closure when assessed by anterior segment swept source OCT (SS-OCT, CASIA SS-1000; Tomey, Nagoya, Japan) and gonioscopy.MethodsCross-sectional study. A total of 2027 phakic subjects aged ≥50 years, with no relevant previous ophthalmic history, were consecutively recruited from a community polyclinic in Singapore. Gonioscopy and SS-OCT (128 radial scans) for the entire circumference of the angle were performed for each subject. A two-quadrant closed gonioscopic definition was used. On SS-OCT images, angle closure was defined as iridotrabecular contact (ITC) to the extent of ≥35%, ≥50% and ≥75% of the circumferential angle. Diagnostic disagreements between both methods, that is, false positives or overcalls and false negatives or undercalls were defined, respectively, as gonioscopic open/closed angles inversely assessed as closed/open by SS-OCT.ResultsTwo hundred and seventy-two (14.7%) resulted in overcall results (false positives) when ≥50% of the angle circumference was closed using SS-OCT. These eyes had significantly wider (anterior chamber width, 11.7 vs 11.6 mm, p<0.001) and deeper (anterior chamber depth (ACD), 2.4 vs 2.2 mm, p<0.001) anterior chambers than eyes assessed by both methods as closed (true positives). Deeper ACD (OR 9.31) and lower lens vault (LV) (OR 0.04) were significantly associated with a false positive diagnosis in the multivariate analysis. Most of these cases had short (52.6%) or irregular (39%) ITC in SS-OCT images.ConclusionsWe found that anterior chamber dimensions, determined by ACD and LV, were factors significantly associated with diagnostic disagreement between anterior segment SS-OCT and gonioscopy in angle closure assessment.


2021 ◽  
Author(s):  
Inês Almeida ◽  
Libânia Dias ◽  
Jeniffer Jesus ◽  
Inês Fonseca ◽  
Maria João Matias ◽  
...  

Abstract Background: Herpes simplex virus (HSV) keratitis remains a leading infectious cause of blindness worldwide. This study instends to investigate the potential of Optical Coherence Tomography Angiography (OCTA) device to image and describe quantitatively the vascularization in eyes diagnosed with herpetic leucoma and to discuss and review the usefulness of this technique in this pathology. Methods: A Cross-sectional study was made, including 17 eyes of 15 patients with leucoma secondary to herpetic keratitis. All eyes underwent anterior segment Slit-Lamp photography (SLP), and Optical Coherence Tomography Angiography (OCT) with en-face, b-scans and c-scans imaging. The vessel density (VD) was analyzed in the inferior, nasal and temporal corneal margin in all patients, and in the central area, in eyes with central corneal neovascularization (CoNV). The measurements were calculated after binarization with ImageJ software, using OCTA scans with 6x6 mm in a depth of 800 μm. Results: Patients included had a mean age 53.267±21.542 (years±SD). The mean total vessel area was 50.907±3.435%. VD was higher in the nasal quadrant (51.156±4.276) but there were no significant differences between the three analyzed areas (p=0.940). OCTA was able to identify abnormal vessels when SLP apparently showed no abnormal vessels; OCTA was able to distinguish between larger and smaller vessels even in central cornea; OCTA scans allowed the investigation of several corneal planes and the relation of them with clinical findings. Conclusions: OCTA can be useful in both qualitative and quantitative follow-up of patients and may become a non-invasive alternative to objectively monitor treatment response in eyes with corneal vascularization due to herpetic infection.


2019 ◽  
Author(s):  
Tingting Hong ◽  
Xin Meng ◽  
Xinxiao Gao ◽  
Jun Wang

Abstract Background: Using spectral-domain optical coherence tomography (SD-OCT) to investigate choroidal vascular sublayers in Chinese pre-eclampsia (PE) and healthy pregnancy. Methods: This was an observational, cross-sectional study, including 20 normal subjects, 23 healthy pregnancy and 37 patients with PE. Using SD-OCT, subfoveal choroidal thickness (SFCT), 750μm nasal and temporal to the fovea, 1500μm nasal and temporal to the fovea(T1500, T750, SFCT, N750, N1500)and sublayers (choriocapillaris/Sattler layer and Haller layer) were measured. Results: There was no significant difference in mean age, spherical equivalent among the three groups (P=0.532). Additionally, no significant difference in the gestational age between the healthy pregnancy and PE group was found (P=0.783). Significant differences were seen in large choroid vessel thickness(LCVT), medium choroidal vessel thickness (MCVT) and choroidal thickness (CT) at 5 locations among three groups (P<0.05). There was significant increase in healthy pregnancy group than in normal subjects at N1500-CT, N750-CT, SFCT, T750-CT and MCVT (P<0.05), while no significant difference was observed at T1500CT and LCVT (P>0.05). Meanwhile, significant increase was detected in PE group than in healthy pregnancy group at N1500-CT, N750-CT, SFCT, T750-CT, T1500CT and LCVT (P<0.05), whereas no significant difference was observed at MCVT(P=0.709). Conclusion: Our study revealed the variation of choroidal vascular sublayers during pregnancy and PE. Key words: Pre-eclampsia, subfoveal choroidal thickness, choroidal sublayers, optical coherence tomography


2022 ◽  
Author(s):  
Ismail Ersan ◽  
Sevilay Kılıc ◽  
Selda Isık

Abstract Purpose: To evaluate the epithelial and stromal thicknesses of conjunctiva and cornea in psoriatic patients with anterior segment optical coherence tomography (AS-OCT),Methods: In this cross-sectional study, 61 patients with psoriasis and 42 age-matched, healthy individuals were enrolled. The epithelial and stromal thicknesses of both inferotemporal bulbar conjunctiva and central cornea were measured using AS-OCT. Results: Both the Tear break-up time and Schirmer-1 test values were significantly lower in the psoriasis group compared with the controls (p<0.05). The epithelial thickness of conjunctiva and cornea did not differ between psoriasis and control groups. (p>0.05) The central corneal stroma was significantly thicker in the psoriasis group (p=0.04). PASI was positively correlated with the thickness of central cornea stroma (r=0.442, p=0.006) in the nail psoriasis group. Conclusions: Psoriasis is not associated with altered epithelial thicknesses of the cornea and conjunctiva. It is accompanied by the stromal thickening of the cornea without conjunctival stromal involvement.


2018 ◽  
Vol 16 (2) ◽  
pp. 86-94
Author(s):  
Vijaya Anandan ◽  
Rekha Srinivasan ◽  
Rashima Asokan ◽  
Ronnie George

Aim: To compare the anterior chamber volume measurements obtained with Pentacam and derived from anterior segment optical coherence tomography. Design: Cross-sectional study. Methods: We included normal subjects who underwent a comprehensive eye examination including refraction, keratometry, Goldmann applanation tonometry, gonioscopy, anterior segment optical coherence tomography (AS-OCT) (Carl Zeiss Meditec Inc.; Dublin, CA, USA) and Pentacam (Oculus Inc.; Lynnwood, WA, USA). Fifty scans were selected for Pentacam and 12 images were selected for calculation of anterior chamber volume. Only the right eye was considered for analysis. Results: One-hundred and nineteen eyes of 119 subjects were included for analysis. The mean age of the subjects was 42.58 ± 13.15 years, of which 74 were female and 45 were male. The mean anterior chamber volume measured using AS-OCT was 119.17 ± 26.56 mm3 and with Pentacam was 131.29 ± 34.26 mm3. The comparison of means between the two modalities was statistically significant (t = -8.857, Mean Difference (MD) = 12.11, 95% CI: (4.29, 19.95), p = 0.003). Bland-Altman plot showed poor agreement between the chamber volume measurements obtained by Pentacam and AS-OCT with MD of 12.1 mm3 (95 % CI: 41.4 to -17.1) and intra-class correlation between the two instruments was 0.94 (95% CI: 0.91, 0.96) (p < 0.0001). Conclusion: The anterior chamber volume can be measured using Pentacam as well as AS-OCT since these measurements were reliable. However, these measurements were not interchangeable due to poor levels of agreement.


Sign in / Sign up

Export Citation Format

Share Document