scholarly journals Development and Validation of RP-HPLC Method for the Determination of Hydrochlorothiazide in Bulk Drug and Pharmaceutical Dosage Form

2016 ◽  
Vol 2016 ◽  
pp. 1-7 ◽  
Author(s):  
Nidhal S. Mohammed ◽  
Ahmed J. Mohammed

An HPLC-PDA method was developed and validated for the determination of hydrochlorothiazide in bulk and pharmaceutical formulation. The method was optimized selecting chromatographic conditions of 50 : 50 acetonitrile : water, Inertsil® column (ODS-3 250 mm × 4.6 mm 5 μm), 20 μL injection volume, flow rate of 1 mL/min at ambient temperature (30°C), and 272 nm. Another column of C18Zorbax® (Eclipse Plus, 4.6 × 250 mm, 5 μm) was tested showing no big difference in the method results. The method was validated giving good precision (RSD% < 1), acceptable linearity (R2 ≥ 0.9978), and low LOD and LOQ (0.5 and 1.7 μg/mL, resp.) on both columns. Successful application on pharmaceutical dosage tablet form gave high recovery of 99.93%. The method was compared with official BP and other reported methods. The proposed method is economic, simple, and rapid and hence can be employed for routine analysis in quality control laboratories.

Author(s):  
Ankit Acharya ◽  
N.K. Satish ◽  
L. Manoj ◽  
Renukaradhya Chitti

The main objective of present study is to develop and validate a new, simple, precise and accurate RP-HPLC method for the determination of Darifenacin Hydrobromide (DFH) in bulk and pharmaceutical dosage forms. The separation and quantification of the drug was achieved on a RP C18 column (250×4.6mm, 5μm) using a mobile phase of acetonitrile: buffer (50:50), pH 3.0 ± 0.2 at a flow rate of 1 mL/min with detection of analyte at 287 nm. The separation was achieved with in 4.0 ± 0.3 min. The method showed good linearity in the range of 10-100 μg/mL. The intra and inter day RSD ranged from 0.20-0.58%. The recovery (mean ± SD) of low, medium and high concentrations were 98.50 ± 0.20, 100.27 ± 0.15 and 100.90 ± 0.09 respectively. The limit of detection and limit of quantification were 0.31 and 0.61 μg/mL, respectively. It can be concluded that the present method could be superior over the methods which were reported earlier. Kathmandu University Journal of Science, Engineering and TechnologyVol. 13, No. 1, 2017, Page: 36-44 


INDIAN DRUGS ◽  
2014 ◽  
Vol 51 (12) ◽  
pp. 32-36
Author(s):  
T. Vishalakhi ◽  
◽  
S. K Kumar ◽  
K Sujana ◽  
P Rani

A simple validated RP HPLC method for the estimation of rizatriptan benzoate in pharmaceutical dosage form and bulk was developed for routine analysis. This method was developed by selecting Agilent TC C18 (250 x 4.6 mm, 5 μ) column as stationary phase and acrylonibrile:water (45:55), pH adjusted to 3, as mobile phase. Flow rate of mobile phase was maintained at 4: 1 mL/min at ambient temperature throughout the experiment. Quantification was achieved with ultraviolet (DAD) detection at 220 nm. The retention time obtained for rizatriptan was 2.8 min. The detector response was linear in the concentration range of 2-25μg/mL. This method was validated and shown to be specific, sensitive, precise, linear, accurate, rugged and robust. Hence, this method can be applied for routine quality control of rizatriptan benzoate in dosage forms as well as in bulk drug.


Author(s):  
Zahid Zaheer ◽  
Sarfaraz Khan ◽  
Mohammad Sadeque ◽  
Hundekari G. I. ◽  
Rana Zainuddin

A simple, reproducible and efficient reverse phase high performance liquid chromatographic method was developed for Lisinopril in bulk drug and formulation. A column having 150 × 4.6 mm in isocratic mode with mobile phase containing acetonitrile: phosphate buffer (70:30; adjusted to pH 3.0) was used. The flow rate was 0.8 ml/min and effluent was monitored at 216 nm. The retention time (min) and linearity range (μg/ml) for Lisinopril was (1.510) and (10-35). The developed method was found to be accurate, precise and selective for determination of Lisinopril in bulk and formulation.


Author(s):  
Wamorkar V V ◽  
C S Ramaa ◽  
Manjunath S Y ◽  
V Malla Reddy

RP-HPLC method has been developed and validated for the determination of voricaonazole in bulk drug. The developed method is found to be specific, reproducible, and stability indicating. The Hypersil, C18 (250 X 4.6 mm) 5μ column was used and mobile phase consisting of water:acetonitrile to achieve good resolution and retention of the analyte and its impurities. The detector linearity was established from concentrations ranging from 5-100 μg/ml. The method was tested at different levels of specificity and accuracy as per requirements given in ICH guidelines. The molecule was exposed to the stress conditions such as acid, base, oxidation, heat and light as per the recommendations of ICH guidelines. The method was proved to be robust with respect to changes in flow rate, mobile phase composition and allied columns. The proposed method is found to be sensitive, precise, rapid, reproducible, and offers good column life.


Author(s):  
Abhishek Agrawal ◽  
Prem Kumar Bichala ◽  
Swapna Singh

RP-HPLC method was developed for the determination for the validation of Nitazoxanide and Ofloxacin in pharmaceutical dosage form. Chromatographic separation was performed on Develosil ODS HG-5 RP C18, 15x4.6mm, 5µm column, with mobile phase comprising of mixture of ACN: Methanol: Citric acid in the ratio of 50:45:5 v/v, at the flow rate 1.0ml/min and the detection was carried out at 296nm. The comprehensive forced stress testing has been carried out as per USP guidelines. The drug Nitazoxanide is subjected to synthetic Benzamide, and the drug Ofloxacin is subject to synthetic Fluoroquinolone. RP- HPLC method was developed to separate analyte from all other degradation peaks. The method was successfully validated as per ICH guidelines for the purpose of conducting studies of the analyte in quality control laboratory. The drug was subjected to different degradation conditions; it was found to be stable in all degradation conditions. The purposed HPLC method was found to be precise, specific, accurate, rapid and economical for the determination of Nitazoxanide and Ofloxacin in pharmaceutical dosage form. The sample recoveries in all formulations were in good agreement with their respective label claims and this method can be used for routine analysis. The linearity range was found to be 0-50 (µg/ml) for Nitazoxanide and 0-50 (µg/ml) for Ofloxacin. Calibration curve was plotted and correlation co-efficient for the drugs found to be 0.999 and 0.997. Hence the results obtained were within the limits.


2011 ◽  
Vol 8 (1) ◽  
pp. 453-456 ◽  
Author(s):  
K. Srinivasu ◽  
J. Venkateswara Rao ◽  
N. Appala Raju ◽  
K. Mukkanti

A validated RP HPLC method for the estimation of atazanavir in capsule dosage form on YMC ODS 150 × 4.6 mm, 5 μ column using mobile phase composition of ammonium dihydrogen phosphate buffer (pH 2.5) with acetonitrile (55:45 v/v). Flow rate was maintained at 1.5 mL/min with 288 nm UV detection. The retention time obtained for atazanavir was at 4.7 min. The detector response was linear in the concentration range of 30 - 600 μg/mL. This method has been validated and shown to be specific, sensitive, precise, linear, accurate, rugged, robust and fast. Hence, this method can be applied for routine quality control of atazanavir in capsule dosage forms as well as in bulk drug.