scholarly journals The Acoustical Behavior of Contra-Rotating Fan

2018 ◽  
Vol 2018 ◽  
pp. 1-8
Author(s):  
Juan Wu ◽  
Ziming Kou ◽  
Jing Liu

The noise produced by a contra-rotating ventilator can cause injury to humans. Therefore, it is important to reduce noise caused by ventilators. In this study, the Ffowcs Williams and Hawkings (FW-H) model was used to simulate the acoustics of four different axial impeller spacing points based on the unsteady flow field through a FBD No. 8.0 contra-rotating ventilator. Experiments were conducted to verify the correctness of the numerical model. Meanwhile, the Variable Frequency Drive (VFD) drives the two motors of 55 kW to give the impellers different speeds to distinguish different conditions. The results showed that the main noise source of the ventilator was the two rotating impellers and the area between them. For the same axial space, the noise decreased with the increase of flow rate and then decreased. And the amplitude of the discrete pulse increased gradually. It can be concluded that the vortex acoustics decreased gradually with the increase of flow rate and the rotating acoustics were the major contributor. With the axial distance increasing, the noise caused by the two impellers was weak, and the frequencies of sound pressure level moved toward medium- and low-frequency bands gradually. The suitable axial space could reduce noise and improve the working environment.

1964 ◽  
Vol 7 (1) ◽  
pp. 17-29 ◽  
Author(s):  
Nobuhiko Isshiki

The relationship between the voice intensity (sound pressure level), the subglottic pressure, the air flow rate, and the glottal resistance was investigated. Simultaneous recordings were made of the sound pressure level of voice, the subglottic pressure, the flow rate, and the volume of air utilized during phonation. The glottal resistance, the subglottic power, and the efficiency of voice were calculated from the data. It was found that on very low frequency phonation the flow rate remained almost unchanged or even slightly decreased with the increase in voice intensity while the glottal resistance showed a tendency to augment with increased voice intensity. In contrast to this, the flow rate on high frequency phonation was found to increase greatly, while the glottal resistance remained almost unchanged as the voice intensity increased. On the basis of the data it was concluded that at very low pitches, the glottal resistance is dominant in controlling intensity (laryngeal control), becoming less so as the pitch is raised, until at extremely high pitch the intensity is controlled almost entirely by the flow rate (expiratory muscle control).


2009 ◽  
Vol 55 (No. 2) ◽  
pp. 69-75 ◽  
Author(s):  
M. Šístková ◽  
A. Peterka

The noise belongs to the leading harmful factors which pollute the environment and negatively influences human health. An overview measurement concerning the noise characteristics has been done in agricultural service workplaces. The sound pressure level has been measured and the length of the workers exposition has been elicited in each workplace. The obtained data has proved that some agricultural service workers have been exposed to a noise above the permissible exposure limit.


Author(s):  
Yutaka Ohta ◽  
Eisuke Outa

A hybrid-type noise control method is applied to fundamental and higher-order blade-passing frequency components, abbreviated to BPF components, radiated from a centrifugal blower. An active cancellation of the BPF noise source is conducted based on a detailed investigation of the noise source distribution by using correlation analysis. The sound pressure level of 2nd- and/or 3rd-order BPF can be reduced by more than 15 decibels and discrete tones almost eliminate from the power spectra of blower-radiated noise. On the other hand, the sound pressure level of the fundamental BPF is difficult to reduce effectively by the active cancellation method because of the large amplitude of the noise source fluctuation. However, the fundamental BPF is largely influenced by the frequency-response characteristics of the noise transmission passage, and is passively reduced by appropriate adjusting of the inlet duct length. Simultaneous reduction of BPF noise, therefore, can be easily made possible by applying passive and active control methods on the fundamental and higher-order BPF noise, respectively. We also discuss the distribution pattern of BPF noise sources by numerical simulation of flow fields around the scroll cutoff.


Author(s):  
Henry A. Scarton ◽  
Kyle R. Wilt

Sound power levels including the distribution into octaves from a large 149 kW (200 horsepower) gyro rock crusher and separate asphalt plant are presented. These NIST-traceable data are needed for estimating sound pressure levels at large distances (such as occurs on adjoining property to a quarry) where atmospheric attenuation may be significant for the higher frequencies. Included are examples of the computed A-weighted sound pressure levels at a distance from the source, including atmospheric attenuation. Substantial low-frequency sound power levels are noted which are greatly reduced in the far-field A-weighted sound pressure level calculations.


2010 ◽  
Vol 57 (4) ◽  
pp. 393-404
Author(s):  
Riza Gürbüz

Controlling Flow Rate and Fluid Level by Variable Frequency Drive Unit The Variable Frequency Drive (VFD) is used to control the speed of the pumpmotor to attain the desired flow rate and fluid level in a fluid system. An AC drive provides efficient flow control by varying the pump-motor speed. The comparison of energy requirements and costs in a system where a throttling device is used for flow control on a centrifugal pump with the power used when an variable frequency drive (VFD) is used to control the same flow, evidently shows potential savings. In this system, AC Motor Frequency drive and static pressure transmitter, turbine type flowmeter and Analog/Digital cards, micro-control unit and computer connection are designed specially to control flow rate, fluid flow type (turbulence or laminar) and water level at the different conditions with different PID parameters.


Author(s):  
Cristian F. Jaimes Saavedra ◽  
Sebastian Roa Prada ◽  
Jessica G. Maradey Lázaro

Pumping processes often require different operating conditions for the same pipeline. The conditions downstream in the pipeline can change in such a way that the pressure at the discharge of the pump may vary, which automatically introduces changes in the flow supplied by the pump into the pipeline due to the head vs flow characteristic curve of the pump. Even under varying pipeline pressure conditions, it may be necessary to keep the flow discharge of the pump constant. The two most commonly used control strategies for flow control with centrifugal pumps are by means of a fixed-speed pump and a control valve at the outlet of the pump, or by means of a variable frequency drive which avoids the need for the control valve. It has been demonstrated that the approach with the fixed-speed pump and the control valve provides poor power efficiency results, so a variable frequency drive is normally the solution of choice in industry applications. The use of a variable frequency drive allows reaching the flow required by the system without changing the physical characteristic of the pump or pipeline, i.e., it is not necessary to shut the system down to replace the impeller of the pump. However, affinity laws of centrifugal pumps dictate that a change in the rotational speed of the impeller shifts the characteristic curves of the pump, not only the flow vs head curve, but also the efficiency curves, among others. Besides, searching for a different operating point by changing the speed of the pump does not necessarily guarantees optimal operating power efficiency. This paper proposes an optimization approach where a compromise is made between flow control and power efficiency by minimizing the error in the flow rate while at the same time maximizing the power efficiency. To accomplish this goal, this paper presents the modeling of the pump and pipeline, and the design of a linear quadratic regulator control for the fluid flow passing through a given pipeline. The fluid under consideration is water. The mathematical model of the overall system is derived by considering the model of an AC motor, the pump and the hydraulic circuit. Then, with the help of the software MATLAB, the controller was designed and implemented with the linearized mathematical model. The actuator of the control system is the variable frequency drive that changes the speed of the impeller to adjust the flow rate to the required operating point under different loading conditions. The results show the behavior of the compensated system with the optimal controller. In practice, the control system must take into account the constraints of the control effort, which means, the frequency of the pump must be kept within safe values to achieve proper functioning of the pumping system.


2018 ◽  
Vol 10 (8) ◽  
pp. 168781401879481 ◽  
Author(s):  
Enbin Liu ◽  
Shanbi Peng ◽  
Tiaowei Yang

When a natural gas transmission and distribution station performs a planned or emergency venting operation, the jet noise produced by the natural gas venting pipe can have an intensity as high as 110 dB, thereby severely affecting the production and living environment. Jet noise produced by venting pipes is a type of aerodynamic noise. This study investigates the mechanism that produces the jet noise and the radiative characteristics of jet noise using a computational fluid dynamics method that combines large eddy simulation with the Ffowcs Williams–Hawkings acoustic analogy theory. The analysis results show that the sound pressure level of jet noise is relatively high, with a maximum level of 115 dB in the low-frequency range (0–1000 Hz), and the sound pressure level is approximately the average level in the frequency range of 1000–4000 Hz. In addition, the maximum and average sound pressure levels of the noise at the same monitoring point both slightly decrease, and the frequency of the occurrence of a maximum sound pressure level decreases as the Mach number at the outlet of the venting pipe increases. An increase in the flow rate can result in a shift from low-frequency to high-frequency noise. Subsequently, this study includes a design of an expansion-chamber muffler that reduces the jet noise produced by venting pipes and an analysis of its effectiveness in reducing noise. The results show that the expansion-chamber muffler designed in this study can effectively reduce jet noise by 10–40 dB and, thus, achieve effective noise prevention and control.


2018 ◽  
Vol 37 (2) ◽  
pp. 373-384
Author(s):  
Hiroshi Sato ◽  
Jongkwan Ryu ◽  
Kenji Kurakata

An on-site system for measuring low-frequency noise and complainant's responses to the low-frequency noise was developed to confirm whether the complainant suffer from the environmental noise with low-frequency components. The system suggests several methods to find the dominant frequency and major sound pressure level spectrum of the noise causing annoyance. This method can also yield a quantified relationship (correlation coefficient and percentage of response to the noise) between physical noise properties and the complainant’s responses. The advantage of this system is that it can easily find the relationship between the complainant’s response to the acoustic event of the houses and the physical characteristics of the low-frequency noise, such as the time trends and frequency characteristics. This paper describes the developed system and provides an example of the measurement results.


2007 ◽  
Vol 26 (2) ◽  
pp. 81-89 ◽  
Author(s):  
A T Moorhouse ◽  
D C Waddington ◽  
M D Adams

Results of laboratory tests are presented in which 18 subjects, including some low frequency noise sufferers, were presented with low frequency sounds with varying degrees of fluctuation. Thresholds of acceptability were obtained for each sound and each subject, using the method of adjustment. These thresholds were then normalised to individual low frequency hearing threshold. It was found that sufferers tend to set thresholds of acceptability closer to their hearing threshold than other subject groups. Also, acceptability thresholds were set on average 5dB lower for fluctuating sounds. It is proposed that a sound should be considered fluctuating when the difference between L10 and L90 exceeds 5dB, and when the rate of change of the ‘Fast’ response sound pressure level exceeds 10dB/s