scholarly journals Investigation of a Modified Novel Technique in Bilateral Sagittal Splitting Osteotomy Fixation: Finite Element Analysis and In Vitro Biomechanical Test

2020 ◽  
Vol 2020 ◽  
pp. 1-8
Author(s):  
Li-Ren Chang ◽  
Chien-Chung Chen ◽  
Seng Feng Jeng ◽  
Yu-Ray Chen ◽  
Lain-Chyr Hwang ◽  
...  

Purpose. To evaluate the biomechanical properties of the modified novel 2-hole monocortical plate fixation (2HMCPf) and traditional 4-hole monocortical plate fixation (4HMCPf) techniques in bilateral sagittal splitting osteotomy (BSSO) synthesis using a finite element analysis (FEA) and an in vitro biomechanical test with the application of a shearing loading force on a sawbone mandible model. Materials and Methods. A three-dimensional mandible models were generated using the geometry obtained from the computerized tomography image of a sawbone mandible. Plates and screws were generated and combined with the mandible in a CAD environment. The 2HMCPf and traditional 4HMCPf techniques for BSSO osteosynthesis were then analyzed under the occlusal load using the FEA. An in vitro biomechanical test was executed to verify the result of FEA. The force on fixation failure and pattern of failure were recorded. Results. The results revealed that the von Mises Stress on the mandible cortical bone (75.98 MPa) and the screw/plate (457.19 MPa) of the 2HMCPf group was lower than that of the 4HMCPf group (987.68 MPa, 1781.59 MPa). The stress concentrated on the central region of the 4HMCPf group and the distal set of the 2HMCPf group. In vitro study using the sawbone mandible model showed mechanical failure at the region of the proximal segment near the osteotomy site with the 4HMCPf group (average 32.198 N) but no failure on the fixation sites with the 2HMCPf group. Instead, the mandible sawbone fractured on the condyle neck region (average 44.953 N). Conclusion. From the biomechanical perspective, we proved that the 2HMCPf method was able to withstand a higher shearing loading force than the 4HMCPf fixation method in BSSO osteosynthesis.

2018 ◽  
Vol 2018 ◽  
pp. 1-8
Author(s):  
Hao Zhang ◽  
Jiantao Li ◽  
Jianfeng Zhou ◽  
Lianting Li ◽  
Ming Hao ◽  
...  

Objectives. We evaluated the biomechanical outcome of different plate fixation strategies (the single plate construct, 45° double-plate construct, 90° double-plate construct, 135° double-plate construct, and 180° double-plate construct) used for the fixation of the femoral shaft nonunion with no cortical support opposite the primary lateral plate. This may help surgeons choose the optimal therapy to the femoral shaft nonunion. Methods. The femoral shaft nonunion with no medial support and the models of lateral plate and medial plate was constructed in 3-matic software and UG-NX software, respectively. We then assembled the single plate and different double plates to the fracture model separately to form the fixation models. After meshing the models’ elements, we used the ABAQUS software to perform the finite element analysis. Values of the von Mises Stress (VMS) distribution of the implant, peak VMS, and model displacement and deformation were used to capture the mechanical factors in this study. Results. Our results indicated that the peak von Mises Stress (VMS) of the lateral plate was concentrated in middle surface of the lateral plate near the fragment of each group. The peak VMS was 5201.0 MPa (the single-plate construct), 3490.0 MPa (45° double-plate construct), 1754.0 MPa (90° double-plate construct), 1123.0 MPa (135° double-plate construct), and 816.5 MPa (180° double-plate construct). The additional short plate dispersed some stress leading to the decrease in the peak VMS of the lateral plate. As angle formed by the double plates increased, the dispersed function of the additional plate was becoming obvious. The bending angles of the lateral plate were 18° versus 12° versus 3° versus 2° versus 1° (the single-plate construct versus 45° double-plate construct versus 90° double-plate construct versus 135° double-plate construct versus 180° double-plate construct). Conclusions. Our study indicated that increasing the angle between the plates in a double-plate construct improves the stability of the construct over a single lateral plate when there is no cortical support opposite to the lateral plate. The strongest fixation occurred when the angle between the two plates was greater than ninety degrees.


2007 ◽  
Vol 20 (04) ◽  
pp. 285-290 ◽  
Author(s):  
D. P. Comiskey ◽  
B. Mac Donald ◽  
C. B. Garvan ◽  
W. T. Mc Cartney

SummaryFourteen Spaniels that presented with an intercondylar fracture of the distal humerus were managed using a lateral plate and an additional pin in twelve cases. Fixation of the fracture was achieved using a plate applied laterally which incorporated the transcondylar lag screw in the most distal hole. Of the 14 cases, two had poor results, one of which was a bilateral case, whilst the remaining 12 cases had good or very good results with only occasional stiffness or lameness. Finite element (FE) modelling of a distal humerus was generated, and loading of fracture repairs using a lateral plate and caudal plate was completed in a comparative study to determine which fixation method resisted micro-motion most effectively. Finite element analysis revealed that the lateral plate fixation provided significantly more resistance to micro movement at the fracture site that the caudal plate fixation, with 40% more micro-motion in the latter.


Materials ◽  
2019 ◽  
Vol 12 (2) ◽  
pp. 235 ◽  
Author(s):  
Won Kim ◽  
Eun Song ◽  
Kyung Ju ◽  
Jong-Ho Lee ◽  
Man Kim ◽  
...  

Peri-implantitis is a common complication following dental implant placement, which may lead to bone loss and fixation failure. With the conventional fixture, it is difficult to perfectly clear-up the infection. To solve this, we have designed a separable fixture of which the top part is replaceable. This study aimed to compare the structural and biomechanical stability of the separable and conventional fixture. A single surgical model corresponding to the first molar in a virtual mandible model and conventional/separable implants were reproduced to compare the biomechanical characteristics of the implants using finite element analysis (FEA). The loading condition was 200N preload in the first step, and 100N (Axial), 100N (15°), and 30N (45°) in the second step. The stress distribution on the cortical bone in the separable implant was lower than the conventional implant. In particular, the Peak von Mises Stress (PVMS) values of the separable implant under lateral load was found to be about twice as low as that of the conventional implant. In this study, we suggest that the separable implant has an equivalent biomechanical stability compared to the conventional implant, is easy to retrieve in the case of peri-implantitis, and has an excellent initial stability after the surgery when used in stage 2.


2021 ◽  
Vol 11 (6) ◽  
pp. 2547 ◽  
Author(s):  
Carlo Prati ◽  
João Paulo Mendes Tribst ◽  
Amanda Maria de Oliveira Dal Piva ◽  
Alexandre Luiz Souto Borges ◽  
Maurizio Ventre ◽  
...  

The aim of the present investigation was to calculate the stress distribution generated in the root dentine canal during mechanical rotation of five different NiTi endodontic instruments by means of a finite element analysis (FEA). Two conventional alloy NiTi instruments F360 25/04 and F6 Skytaper 25/06, in comparison to three heat treated alloys NiTI Hyflex CM 25/04, Protaper Next 25/06 and One Curve 25/06 were considered and analyzed. The instruments’ flexibility (reaction force) and geometrical features (cross section, conicity) were previously investigated. For each instrument, dentine root canals with two different elastic moduli(18 and 42 GPa) were simulated with defined apical ratios. Ten different CAD instrument models were created and their mechanical behaviors were analyzed by a 3D-FEA. Static structural analyses were performed with a non-failure condition, since a linear elastic behavior was assumed for all components. All the instruments generated a stress area concentration in correspondence to the root canal curvature at approx. 7 mm from the apex. The maximum values were found when instruments were analyzed in the highest elastic modulus dentine canal. Strain and von Mises stress patterns showed a higher concentration in the first part of curved radius of all the instruments. Conventional Ni-Ti endodontic instruments demonstrated higher stress magnitudes, regardless of the conicity of 4% and 6%, and they showed the highest von Mises stress values in sound, as well as in mineralized dentine canals. Heat-treated endodontic instruments with higher flexibility values showed a reduced stress concentration map. Hyflex CM 25/04 displayed the lowest von Mises stress values of, respectively, 35.73 and 44.30 GPa for sound and mineralized dentine. The mechanical behavior of all rotary endodontic instruments was influenced by the different elastic moduli and by the dentine canal rigidity.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Daisuke Takahashi ◽  
Yoshihiro Noyama ◽  
Tsuyoshi Asano ◽  
Tomohiro Shimizu ◽  
Tohru Irie ◽  
...  

Abstract Background Internal fixation is recommended for treating Vancouver B1 periprosthetic femoral fractures. Although several fixation procedures have been developed with high fixation stability and union rates, long-term weight-bearing constructs are still lacking. Therefore, the aim of the present study was to evaluate the stability of a double-plate procedure using reversed contralateral locking compression-distal femoral plates for fixation of Vancouver B1 periprosthetic femoral fractures under full weight-bearing. Methods Single- and double-plate fixation procedures for locking compression-distal femoral plates were analysed under an axial load of 1,500 N by finite element analysis and biomechanical loading tests. A vertical loading test was performed to the prosthetic head, and the displacements and strains were calculated based on load-displacement and load-strain curves generated by the static compression tests. Results The finite element analysis revealed that double-plate fixation significantly reduced stress concentration at the lateral plate place on the fracture site. Under full weight-bearing, the maximum von Mises stress in the lateral plate was 268 MPa. On the other hand, the maximum stress in the single-plating method occurred at the defect level of the femur with a maximum stress value of 1,303 MPa. The principal strains of single- and double-plate fixation were 0.63 % and 0.058 %, respectively. Consistently, in the axial loading test, the strain values at a 1,500 N loading of the single- and double-plate fixation methods were 1,274.60 ± 11.53 and 317.33 ± 8.03 (× 10− 6), respectively. Conclusions The present study suggests that dual-plate fixation with reversed locking compression-distal femoral plates may be an excellent treatment procedure for patients with Vancouver B1 fractures, allowing for full weight-bearing in the early postoperative period.


Author(s):  
Osezua Obehi Ibhadode ◽  
Ishaya Musa Dagwa ◽  
Akii Okonigbon Akhaehomen Ibhadode

Calibration curves of a multi-component dynamometer is of essence in machining operations in a lathe machine as they serve to provide values of force and stress components for cutting tool development and optimization. In this study, finite element analysis has been used to obtain the deflection and stress response of a two component cutting tool lathe dynamometer, for turning operation, when the cutting tool is subjected to cutting and thrust forces from 98.1N to 686.7N (10 to 70kg-wts), at intervals of 98.1N(10kg-wt). By obtaining the governing equation, modeling the dynamometer assembly, defining boundary conditions, generating the assembly mesh, and simulating in Inventor Professional; horizontal and vertical components of deflection by the dynamometer were read off for three different loading scenarios. For these three loading scenarios, calibration plots by experiment compared with plots obtained from simulation by finite element analysis gave accuracies of 79%, 95%, 84% and 36%, 57%, 63% for vertical and horizontal deflections respectively. Also, plots of horizontal and vertical components of Von Mises stress against applied forces were obtained.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Charles Savoldelli ◽  
Elodie Ehrmann ◽  
Yannick Tillier

AbstractWith modern-day technical advances, high sagittal oblique osteotomy (HSOO) of the mandible was recently described as an alternative to bilateral sagittal split osteotomy for the correction of mandibular skeletal deformities. However, neither in vitro nor numerical biomechanical assessments have evaluated the performance of fixation methods in HSOO. The aim of this study was to compare the biomechanical characteristics and stress distribution in bone and osteosynthesis fixations when using different designs and placing configurations, in order to determine a favourable plating method. We established two finite element models of HSOO with advancement (T1) and set-back (T2) movements of the mandible. Six different configurations of fixation of the ramus, progressively loaded by a constant force, were assessed for each model. The von Mises stress distribution in fixations and in bone, and bony segment displacement, were analysed. The lowest mechanical stresses and minimal gradient of displacement between the proximal and distal bony segments were detected in the combined one-third anterior- and posterior-positioned double mini-plate T1 and T2 models. This suggests that the appropriate method to correct mandibular deformities in HSOO surgery is with use of double mini-plates positioned in the anterior one-third and posterior one-third between the bony segments of the ramus.


2021 ◽  
Vol 4 (2) ◽  
Author(s):  
Mubni Nazar ◽  
Anggito Pringgo Tetuko ◽  
Djuhana Djuhana

Penelitian ini dilakukan untuk meningkatkan koefisien daya yang maksimal. Salah satunya dengan mengunakan kualitas sudu yang baik. Untuk mengoptimalkan fungsi turbin angin penulis menggunakan material sudu pada turbin angin dengan menggunakan Acrylonitrine Butadine Styrene (ABS). Oleh karena itu pada penelitian ini metode yang digunakan adalah metode Finite Element Analysis Simulasi yang dipilih adalah dynamic. Penelitian ini adalah pengujian kekuatan sudu turbin angin horizontal dengan variasi kecepatan angin 10 – 20 m/s ditinjau dari von mises stress dan displacement. Dari hasil simulasi kecepatan angin memiiki pengaruh terhadap distribusi stress dan displacement. Material yang digunakan masih berada di bawah batas kekuatan material, semakin besar gaya yang diberikan semakin besar nilai stress dan displacement. Pada hasil simulasi didapatkan nilai stress minimum 5.8 Pa stress maksimum 22.94 Sedangkan dalam pengujian displacement dihasilkan nilai minimum 1.27 m displacement maksimum 4.99 m.


Sign in / Sign up

Export Citation Format

Share Document