scholarly journals Peripapillary Microvascularization Analysis Using Swept-Source Optical Coherence Tomography Angiography in Optic Chiasmal Compression

2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Inès Ben Ghezala ◽  
Déa Haddad ◽  
Julie Blanc ◽  
Cyril Meillon ◽  
Rachid Madkouri ◽  
...  

Purpose. To evaluate the vessel density (VD) of the radial peripapillary capillary (RPC) network using swept-source optical coherence tomography angiography (SS-OCTA) “en face” images of eyes with chiasmal compression caused by brain tumors before and after decompressive surgery compared with healthy controls. Methods. A cross-sectional study was conducted in 12 patients with chiasmal compression confirmed by neuroimaging. Sixteen healthy participants were also included. All patients with chiasmal compression underwent a neuro-ophthalmological examination one week before and 6 months after brain surgery, including static automated perimetry as well as measurement of the thickness of the retinal nerve fiber layer (RNFL) and the ganglion cell complex (GCC) with spectral-domain optical coherence tomography (SD-OCT). Based on this neuro-ophthalmological examination, the presence of an optic neuropathy (ON) was evaluated. Peripapillary VD was obtained in four sectors on a 6 × 6 mm SS-OCTA image using the Cirrus Plex Elite 9000. Results. Baseline average VD was significantly lower in patients with chiasmal compression and ON than in controls (median: 55.62; interquartile range (IQR): 2.96 vs. 58.53; IQR: 2.02; p = 0.003 ). This decrease was also found in the temporal, superior, and nasal sectors. Average postoperative VD was decreased in patients with chiasmal compression compared with average preoperative VD (median: 56.16; IQR: 4.07 vs. 57.48; IQR: 3.83; p = 0.004 ). Preoperative VD was significantly correlated with RNFL, GCC thickness, and visual field defects. Conclusions. The VD of the RPC network was decreased in chiasmal compressive ON, and it was further decreased at 6 months after decompressive surgery.

2017 ◽  
Vol 8 (2) ◽  
pp. 362-369 ◽  
Author(s):  
Panagiotis Giannakouras ◽  
Konstantinos Andreanos ◽  
Barbara Giavi ◽  
Andreas Diagourtas

Purpose: To report a case of Vogt-Koyanagi-Harada (VKH) disease and describe the imaging findings by means of optical coherence tomography angiography (OCTA). Methods: Medical and ophthalmological history, ophthalmological examination, laboratory evaluation, B-scan ultrasonography, fluorescein and indocyanine angiography, and optical coherence tomography (OCT) were performed at baseline, as well as OCTA. Results: A 50-year-old healthy female presented with decreased vision in both eyes. A Topcon DRI OCT Triton Plus swept source OCT system was used to visualize and evaluate the retinal and choroidal vascular plexus. Patchy and confluent dark areas in the superficial and deep retinal capillary plexus and choriocapillaris corresponded to areas of hypoperfusion, analyzed as areas of ischemia. Conclusions and Importance: VKH disease is characterized by ocular, neurological, and integumentary findings in its complete form. We present a case of incomplete disease in a 50-year-old female evaluated by means of OCTA which is a novel technique that provides depth-resolved images of the retina and choroidal microvasculature without dye injection that allows better visualization and detailed evaluation of the retinal and choroidal vascular plexus.


Author(s):  
Anna Lentzsch ◽  
Laura Schöllhorn ◽  
Christel Schnorr ◽  
Robert Siggel ◽  
Sandra Liakopoulos

Abstract Purpose To compare swept-source (SS) versus spectral-domain (SD) optical coherence tomography angiography (OCTA) for the detection of macular neovascularization (MNV). Methods In this prospective cohort study, 72 eyes of 54 patients with subretinal hyperreflective material (SHRM) and/or pigment epithelial detachment (PED) on OCT possibly corresponding to MNV in at least one eye were included. OCTA scans were acquired using two devices, the PLEX Elite 9000 SS-OCTA and the Spectralis SD-OCTA. Fluorescein angiography (FA) was used as reference. Two graders independently evaluated en face OCTA images using a preset slab as well as a manually modified slab, followed by a combination of en face and cross-sectional OCTA. Results Sensitivity (specificity) for the automated slabs was 51.7% (93.0%) for SS-OCTA versus 58.6% (95.3%) for SD-OCTA. Manual modification of segmentation increased sensitivity to 79.3% for SS-OCTA but not for SD-OCTA (58.6%). The combination of en face OCTA with cross-sectional OCTA reached highest sensitivity values (SS-OCTA: 82.8%, SD-OCTA: 86.2%), and lowest number of cases with discrepancies between SS-OCTA and SD-OCTA (4.2%). Fleiss kappa as measure of concordance between FA, SS-OCTA, and SD-OCTA was 0.56 for the automated slabs, 0.60 for the manual slabs, and 0.73 (good agreement) for the combination of en face OCTA with cross-sectional OCTA. Concordance to FA was moderate for the automated slabs and good for manual slabs and combination with cross-sectional OCTA of both devices. Conclusion Both devices reached comparable results regarding the detection of MNV on OCTA. Sensitivity for MNV detection and agreement between devices was best when evaluating a combination of en face and cross-sectional OCTA.


2021 ◽  
Vol 10 (12) ◽  
pp. 2658
Author(s):  
Alexis Khorrami Kashi ◽  
Eric Souied ◽  
Selim Fares ◽  
Enrico Borrelli ◽  
Vittorio Capuano ◽  
...  

We evaluated the spectrum of choriocapillaris (CC) abnormalities in the fellow eyes of unilateral exudative age-related macular degeneration (AMD) patients using swept-source optical coherence tomography angiography (SS-OCTA). Fellow eyes of unilateral exudative AMD patients were prospectively included between May 2018 and October 2018. Patients underwent a multimodal imaging including a SS-OCTA. Demographics and clinical findings were analyzed. The estimated prevalence of macular neovascularization (MNV) was computed. Number and size of flow deficits (FDs) and percentage of flow deficits (FD%) were computed on the compensated CC flow images with the Fiji software. We included 97 eyes of 97 patients (mean age was 80 ± 7.66 years, 39 males, 58 females). The prevalence of MNV in the studied eyes was 8.25% (8/97 eyes). In the 89 non-neovascular eyes, FD% averaged 45.84% ± 11.63%, with a corresponding total area of FDs of 4.19 ± 1.12 mm2. There was a higher prevalence of drusenoid pigment epithelial detachment in eyes with subclinical neovascularization (p = 0.021). Fellow eyes with unilateral exudative AMD encompassed a series of CC abnormalities, from FDs of the aging CC to subclinical non-exudative MNV.


2016 ◽  
Vol 2016 ◽  
pp. 1-3 ◽  
Author(s):  
Marcus Ang ◽  
Yijun Cai ◽  
Anna C. S. Tan

Purpose. To describe a novel technique of adapting a swept-source optical coherence tomography angiography (OCTA) to image corneal vascularization.Methods. In this pilot cross-sectional study, we obtained 3 × 3 mm scans, where 100,000 A-scans are acquired per second with optical axial resolution of 8 μm and lateral resolution of 20 μm. This was performed with manual “XYZ” focus without the anterior segment lens, until the focus of the corneoscleral surface was clearly seen and the vessels of interest were in focus on the corresponding red-free image. En face scans were evaluated based on image quality score and repeatability.Results. We analyzed scans from 10 eyes (10 patients) with corneal vascularization secondary to contact lens use in 4 quadrants, with substantial repeatability of scans in all quadrants (mean image quality score 2.7 ± 0.7;κ=0.75). There was no significant difference in image quality scores comparing quadrants (superior temporal: 2.9 ± 0.6, superior nasal: 2.8 ± 0.4, inferior temporal: 2.5 ± 0.9, and inferior nasal: 2.4 ± 1.0;P=0.276) and able to differentiate deep and superficial corneal vascularization.Conclusion. This early clinical study suggests that the swept-source OCTA used may be useful for examining corneal vascularization, which may have potential for clinical applications such as detecting early limbal stem cell damage.


2018 ◽  
Vol 10 (1) ◽  
pp. 356 ◽  
Author(s):  
Bingyao Tan ◽  
Jacqueline Chua ◽  
Veluchamy Amutha Barathi ◽  
Mani Baskaran ◽  
Anita Chan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document