scholarly journals Effects of Aging on the Color and Translucency of Monolithic Translucent Y-TZP Ceramics: A Systematic Review and Meta-Analysis of In Vitro Studies

2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Chang-yuan Zhang ◽  
Check Agingu ◽  
James Kit Hon Tsoi ◽  
Hao Yu

Background. Monolithic restorations made of translucent yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) have become popular over the past few decades. However, whether aging affects the color and translucency of monolithic translucent Y-TZP is unclear. Objective. The aim of this systematic review and meta-analysis of in vitro studies was to evaluate the effects of aging on the color and translucency of monolithic translucent Y-TZP ceramics. Materials and Methods. This systematic review/meta-analysis was reported according to the PRISMA statement and registered in the OSF registries (https://osf.io/5qjmu). Four databases including Medline via the PubMed, Embase, and Web of Science databases and the Cochrane Library were searched using no publication year and language limits. The last search was executed on November 20, 2020. In vitro studies comparing the translucency and/or color of monolithic translucent Y-TZP ceramics before and after simulated aging were selected. Meta-analyses were performed using Review Manager software (version 5.3, Cochrane Collaboration, Oxford, UK) with random-effects models at a significance level of 0.05. A risk-of-bias assessment was also performed for the included studies. Results. Of the 188 potentially relevant studies, 13 were included in the systematic review. The hydrothermal aging duration ranged from 1 to 100 h at relatively similar temperatures (~134°C). In the general meta-analyses, the aged Y-TZP ceramics exhibited similar translucency parameter (TP), L ∗ , and b ∗ values compared with the nonaged controls ( P = .73 , P = .49 , and P = .62 , respectively). Moreover, there was a significant difference between the aged and nonaged Y-TZP ceramics in the a ∗ value ( P = .03 ; MD = − 0.26 ; 95% CI = − 0.51   to − 0.02 ), favoring the nonaged Y-TZP ceramics. The subgroup analyses showed that the duration of aging contributed to changes in the translucency and color of the Y-TZP ceramics. Conclusions. The optical properties of monolithic translucent Y-TZP ceramics were stable after hydrothermal aging at 134°C and 0.2 MPa for ≤20 h. Moreover, clinically unacceptable changes in the translucency and color of monolithic translucent Y-TZP ceramics were found after hydrothermal aging for >20 h.

Hand ◽  
2021 ◽  
pp. 155894472110432
Author(s):  
Emily M. Graham ◽  
Jeremie D. Oliver ◽  
Russell Hendrycks ◽  
Dino Maglic ◽  
Shaun D. Mendenhall

Background The Pulvertaft weave technique (PT) is frequently used during tendon repairs and transfers. However, this technique is associated with limitations. In this systematic review and meta-analysis, quantitative and qualitative analyses were performed on in vitro, biomechanical studies that compared the PT with alternative techniques. Methods Articles included for qualitative and/or qualitative analysis were identified following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies included in the meta-analysis were analyzed either as continuous data with inverse variance and random effects or as dichotomous data using a Mantel-Haenszel analysis assuming random effects to calculate an odds ratio. Results A comprehensive electronic search yielded 8 studies meeting inclusion criteria for meta-analysis. Two studies with a total of 65 tendon coaptations demonstrated no significant difference in strength between the PT and traditional side-to-side (STS) techniques ( P = .92). Two studies with a total of 43 tendon coaptations showed that the STS with 1 weave has a higher yield strength than the PT ( P = .03). Two studies with a total of 62 tendon repairs demonstrated no significant difference in strength between the PT and the step-cut (SC) techniques ( P = .70). The final 2 studies included 46 tendon repairs and demonstrated that the wrap around (WA) technique has a higher yield strength than the PT ( P < .001). Conclusions The STS, SC, and WA techniques are preferred for improving tendon form. The STS and WA techniques have superior yield strengths than the PT, and the SC technique withstands similar stress to failure as the PT.


Author(s):  
Soo Yeon Yang ◽  
Seon Heui Lee ◽  
Seung-Joo Chon

(1) Background: The aim of this work was to systematically review existing studies on whether hysteroscopy improves the reproductive outcomes of women with infertility even in the absence of intrauterine pathologies when compared to women who did not receive a hysteroscopy. (2) Methods: We established the Participant-Intervention-Comparison-Outcome strategy and used the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement to conduct a systematic review of 11 studies which were retrieved from 3 electronic databases: Ovid-Medline, Ovid-Embase, and the Cochrane Library. Two independent investigators extracted the data from the included studies and used the Cochrane risk-of-bias tool to assess their quality. (3) Results: The primary outcome measures were the clinical pregnancy rates (CPRs) and live birth rates (LBRs) in the in vitro fertilization (IVF)/intracytoplasmic sperm injection (ICSI) cycles. Hysteroscopy in infertile women without intrauterine pathologies showed higher CPRs and LBRs than those in the same population who did not receive hysteroscopy in cases of recurrent implantation failure and IVF (odds ratio: 1.79 and 1.46, 95% confidence interval: 1.46-2.30 and 1.08-1.97 for CPR and LBR, respectively); however, the degree of significance was not as high for LBR. (4) Conclusions: Hysteroscopy before IVF/ICSI in infertile women without intrauterine pathologies may potentially be effective in improving the CPRs and LBRs in patients with RIF. Robust and high-quality randomized trials are warranted to confirm this finding.


2021 ◽  
Author(s):  
TG Savian ◽  
J Oling ◽  
FZM Soares ◽  
RO Rocha

Clinical Relevance Vital bleaching impairs the bonding of adhesive systems to enamel and dentin. Thus, restoration placement should be delayed for at least two weeks after completion of bleaching procedures. SUMMARY Objective: This systematic review evaluates the influence of vital bleaching on the bond strength of adhesive systems to enamel and dentin. Methods: This review was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA). In vitro studies comparing the bond strength of bleached and unbleached enamel and dentin were searched at the electronic databases—PubMed/MEDLINE, Scopus, and Web of Science—with no limit on year or language. The studies were screened and had data extracted by two reviewers independently. Bond strength data were meta-analyzed using the inverse variance method and the random effect model (p≤0.05). Results: The electronic search provided 4941 eligible studies, and 52 were included in the systematic review and the meta-analysis. The global meta-analysis showed that bleaching impairs the bond strength of adhesive systems to enamel and dentin (p&lt;0.001; mean difference [MD]: –0.96; confidence interval [CI]: −1.18 to −0.73), regardless of the bleaching agent (p&lt;0.001; MD: −9.98; CI: −1.37 to −0.58) or substrate (p&lt;0.001; MD: −0.89; CI: −1.12 to −0.66). The detrimental effect of bleaching on bond strength was not observed after two and three weeks after bleaching (p=0.1; MD: −0.39; CI: −0.84 to 0.65; and p=0.18; MD: −0.99; CI: −2.45 to 0.47, respectively). Conclusion: This systematic review and meta-analysis demonstrated that vital bleaching impairs the bonding of adhesive systems to enamel and dentin, and this adverse effect persists for two weeks.


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Robin Larsson ◽  
Susanne Bernhardsson ◽  
Lena Nordeman

Abstract Background Subacromial impingement syndrome is a common problem in primary healthcare. It often include tendinopathy. While exercise therapy is effective for this condition, it is not clear which type of exercise is the most effective. Eccentric exercises has proven effective for treating similar tendinopathies in the lower extremities. The aim of this systematic review was therefore to investigate the effects of eccentric exercise on pain and function in patients with subacromial impingement syndrome compared with other exercise regimens or interventions. A secondary aim was to describe the included components of the various eccentric exercise regimens that have been studied. Methods Systematic searches of PubMed, Cochrane Library and PEDro by two independent authors. Included studies were assessed using the PEDro scale for quality and the Cochrane scale for clinical relevance by two independent authors. Data were combined in meta-analyses. GRADE was applied to assess the certainty of evidence. Results Sixty-eight records were identified. Seven studies (eight articles) were included, six were meta-analysed (n = 281). Included studies were of moderate quality (median PEDro score 7, range 5–8). Post-treatment pain was significantly lower after eccentric exercise compared with other exercise: MD -12.3 (95% CI − 17.8 to − 6.8, I2 = 7%, p < 0.001), but this difference was not clinically important. Eccentric exercise provided no significant post-treatment improvement in function compared with other exercise: SMD -0.10 (95% CI − 0.79 to 0.58, I2 = 85%, p = 0.76). Painful eccentric exercise showed no significant difference compared to pain-free eccentric exercise. Eccentric training regimes showed both similarities and diversity. Intervention duration of 6–8 weeks was almost as effective as 12 weeks. Conclusions Evidence of low certainty suggests that eccentric exercise may provide a small but likely not clinically important reduction in pain compared with other types of exercise in patients with subacromial impingement syndrome. It is uncertain whether eccentric exercise improves function more than other types of exercise (very low certainty of evidence). Methodological limitations of existing studies make these findings susceptible to change in the future. Trial registration PROSPERO CRD42019126917, date of registration: 29-03-2019.


Author(s):  
David Fresnais ◽  
Mats B. Humble ◽  
Susanne Bejerot ◽  
Adrian Meehan ◽  
Brynjar Fure

<b><i>Background:</i></b> Emerging evidence suggests that cognitive impairment (CI) and different etiologies of dementia, including Alzheimer’s disease (AD), are associated with vascular risk factors and atherosclerosis. In clinical practice, carotid intima-media thickness (CIMT) measured by ultrasonography may be a marker of atherosclerosis. Many studies report increased CIMT in patients with dementia and CI although a firm association has not yet been established. <b><i>Aim:</i></b> This systematic review and meta-analysis were conducted to study the relationship between CIMT, dementia, and CI. <b><i>Methods:</i></b> The literature search was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and included the following databases: Medline, Embase, Cochrane Library, and Epistemonikos. The search spanned from 2000 to 2020 and was limited to English and Scandinavian languages. <b><i>Results:</i></b> The main analysis of CIMT in subjects with CI compared to subjects with no cognitive impairment (NCI) included 12 studies; 1,089 subjects with CI and 5,223 with NCI. There was no significant difference in CIMT between the CI and NCI groups. However, subgroup analyses revealed significantly higher CIMT in the mild cognitive impairment (MCI) and dementia groups than the NCI group. In addition, patients with dementia had increased CIMT compared to patients with MCI, and patients with AD demonstrated higher CIMT than those with vascular cognitive impairment (VCI). <b><i>Conclusion:</i></b> CIMT may be higher in subjects with CI than in cognitively healthy subjects although no significant difference was observed in our main analysis. CIMT was higher in the dementia group than the MCI group and in the AD group compared to the VCI group.


2020 ◽  
Vol 45 (6) ◽  
pp. 589-597
Author(s):  
BGS Casado ◽  
EP Pellizzer ◽  
JR Souto Maior ◽  
CAA Lemos ◽  
BCE Vasconcelos ◽  
...  

Clinical Relevance The use of laser light during bleaching will not reduce the incidence or severity of sensitivity and will not increase the degree of color change compared with nonlaser light sources. SUMMARY Objective: To evaluate whether the use of laser during in-office bleaching promotes a reduction in dental sensitivity after bleaching compared with other light sources. Methods: The present review was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) and is registered with PROSPERO (CDR42018096591). Searches were conducted in the PubMed/Medline, Web of Science, and Cochrane Library databases for relevant articles published up to August 2018. Only randomized clinical trials among adults that compared the use of laser during in-office whitening and other light sources were considered eligible. Results: After analysis of the texts retrieved during the database search, six articles met the eligibility criteria and were selected for the present review. For the outcome dental sensitivity, no significant difference was found favoring any type of light either for intensity (mean difference [MD]: −1.60; confidence interval [CI]: −3.42 to 0.22; p=0.09) or incidence (MD: 1.00; CI: 0.755 to 1.33; p=1.00). Regarding change in tooth color, no significant differences were found between the use of the laser and other light sources (MD: −2.22; CI: −6.36 to 1.93; p=0.29). Conclusions: Within the limitations of the present study, laser exerts no influence on tooth sensitivity compared with other light sources when used during in-office bleaching. The included studies demonstrated that laser use during in-office bleaching may have no influence on tooth color change.


2020 ◽  
Vol 21 (14) ◽  
pp. 4982 ◽  
Author(s):  
Pietro Gentile ◽  
Aris Sterodimas ◽  
Jacopo Pizzicannella ◽  
Laura Dionisi ◽  
Domenico De Fazio ◽  
...  

Stromal vascular fraction (SVF) containing adipose stem cells (ASCs) has been used for many years in regenerative plastic surgery for autologous applications, without any focus on their potential allogenic role. Allogenic SVF transplants could be based on the possibility to use decellularized extracellular matrix (ECM) as a scaffold from a donor then re-cellularized by ASCs of the recipient, in order to develop the advanced therapy medicinal products (ATMP) in fully personalized clinical approaches. A systematic review of this field has been realized in accordance with the Preferred Reporting for Items for Systematic Reviews and Meta-Analyses-Protocols (PRISMA-P) guidelines. Multistep research of the PubMed, Embase, MEDLINE, Pre-MEDLINE, PsycINFO, CINAHL, Clinicaltrials.gov, Scopus database, and Cochrane databases has been conducted to identify articles and investigations on human allogenic ASCs transplant for clinical use. Of the 341 articles identified, 313 were initially assessed for eligibility on the basis of the abstract. Of these, only 29 met all the predetermined criteria for inclusion according to the PICOS (patients, intervention, comparator, outcomes, and study design) approach, and 19 have been included in quantitative synthesis (meta-analysis). Ninety-one percent of the studies previously screened (284 papers) were focused on the in vitro results and pre-clinical experiments. The allogenic use regarded the treatment of perianal fistulas, diabetic foot ulcers, knee osteoarthritis, acute respiratory distress syndrome, refractory rheumatoid arthritis, pediatrics disease, fecal incontinence, ischemic heart disease, autoimmune encephalomyelitis, lateral epicondylitis, and soft tissue defects. The information analyzed suggested the safety and efficacy of allogenic ASCs and ECM transplants without major side effects.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Micaele Maria Lopes Castro ◽  
Maria Karolina Martins Ferreira ◽  
Iasmin Encaua Essashika Prazeres ◽  
Paula Beatriz de Oliveira Nunes ◽  
Marcela Baraúna Magno ◽  
...  

Abstract Background Previous studies indicated an impact of hormonal contraceptive use on oral health. This systematic review aimed to investigate the evidence supporting the impact of the use of hormonal contraceptives and periodontal diseases. Methods This study is based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and based on the PECO acrostic. Inclusion criteria comprised observational studies including women (P), which evaluated hormonal contraceptive users (E) and hormonal contraceptive non-users (C), to verify the association between this hormonal therapy and the periodontal diseases (O). Searches were performed on 5 databases: PubMed, Scopus, Web of Science, Cochrane Library, LILACS and grey literature (OpenGrey and Google Scholar). After the selection process, the included studies were evaluated qualitatively. Moreover, quantitative data were analyzed in two meta-analyses for clinical attachment loss (CAL) and probing depth (PD). Finally, the level of certainty was measured with the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) tool between periodontal clinical parameters. Results 18 articles were eligible for the qualitative synthesis and 7 of them were selected for quantitative analysis. Hence, 15 of the eligible articles reported an association between the use of hormonal contraceptives and severity of periodontal disease. However, 6 articles demonstrated high risk of bias and were excluded from quantitative synthesis. The meta-analysis showed a statistically significant difference for CAL (MD 0.24 [0.09, 0.40]; p = 0.002), but in PD (MD 0.05 [− 0.05, 0.15]; p = 0.33) such difference was not identified. A very low level of evidence was found between the clinical parameters. Conclusions The use of hormonal contraceptives may be associated to severity of periodontal diseases. However, the quantitative analysis points to an inconclusive outcome due to the high level of heterogeneity. The association is biologically plausible, however additional studies are warranted to better elucidate the clinical significance of this possible association.


Polymers ◽  
2021 ◽  
Vol 13 (14) ◽  
pp. 2251
Author(s):  
Maciej Zarow ◽  
Marzena Dominiak ◽  
Katarzyna Szczeklik ◽  
Louis Hardan ◽  
Rim Bourgi ◽  
...  

Various material properties are involved in the success of endodontically treated restorations. At present, restorative composites are commonly employed as core build-up materials. This study aimed to systematically review the literature to assess the effect of using composite core materials on the in vitro fracture of endodontically treated teeth. Two different reviewers screened the literature, up to June 2021, in five distinct electronic databases: PubMed (MedLine), Scopus, Scielo, ISI Web of Science, and EMBASE. Only in vitro studies reporting the effect of the use of composite core materials on the fracture resistance of endodontically treated teeth were included. A meta-analysis was carried out using a software program (Review Manager v5.4.1; The Cochrane Collaboration, Copenhagen, Denmark). The risk of bias in each study was assessed following the parameters of another systematic review. A total of 5016 relevant papers were retrieved from all databases. After assessing the title and abstract, five publications remained for qualitative analysis. From these, only three studies remained for meta-analysis. The fracture strength of endodontically treated teeth where a core build-up composite was used was statistically significantly higher than the control (p = 0.04). Most of the analyses showed a high heterogenicity. The in vitro evidence suggests that the composite core build-up with higher filler content tended to improve the fracture resistance of the endodontically treated teeth, in comparison with conventional composite resins. This research received no external funding. Considering that this systematic review was only carried out on in vitro papers, registration was not performed. Furthermore, there were no identified clinical studies assessing core build-up materials; therefore, more well-designed research on these materials is needed.