scholarly journals Urrets-Zavalia Syndrome Following Cataract Surgery

2021 ◽  
pp. 659-663
Author(s):  
Shimon Kurtz ◽  
Maayan Fradkin

We describe a case of Urrets-Zavalia syndrome (UZS) in a healthy 56-year-old woman who underwent femtosecond-assisted phacoemulsification with intraocular lens implantation in both eyes. One month after an uneventful postoperative course in the left eye, the right eye was operated. Dilated pupil which was nonreactive to light appeared on day 21 postoperatively. This was discovered upon examination following anterior chamber inflammatory reaction which occurred 2 weeks following her surgery. Our case report emphasizes the importance and danger in developing UZS even if the reaction in the anterior chamber does not occur immediately after surgery. In addition, the importance of intraocular pressure follow-up in the period after UZS is acknowledged.

2017 ◽  
Vol 45 (2) ◽  
pp. 849-855
Author(s):  
Yanfeng Zeng ◽  
Licheng Fan ◽  
Peirong Lu

Objective To observe the treatment effects of chop hook-assisted phacoemulsification surgery in patients with crystalline lens dislocation. Methods Thirty-seven eyes with cataracts and crystalline lens dislocations underwent cataract surgery. An L-shaped chop hook was introduced into the anterior chamber, and the tip was pushed or pulled to the centre of the anterior capsular edge of the zonular dialysis during the cataract operation. Postoperative follow-up was conducted for ≥ 1 month. Results All patients’ postoperative visual abilities improved except one patient with glaucoma. One patient who underwent −5D intraocular lens implantation exhibited vision of 1/50. Visual acuity was less than 6/20 in 6 eyes, 6/20 to 10/20 in 7 eyes, and greater than 10/20 in 22 eyes. Conclusions L-shaped chop hooks can be used to push or pull the anterior capsular edge of the zonular dialysis for protection and avoidance of further zonular damage. This strategy provides satisfactory effects and reduces use of additional instruments.


2019 ◽  
Vol 43 (1) ◽  
pp. 45
Author(s):  
Puty Lestari ◽  
Widyandana Widyandana ◽  
Agus Supartoto

Background: Phakic intraocular lenses (IOL) are being used to correct refractive errors. We studied the pattern of increasing Intraocular Pressure (IOP) after Phakic Anterior chamber intraocular lens implantation as the risk after surgery. Methods: Sixty eyes of 30 patients were enrolled. All eyes underwent the same protocol with IOP examination before surgical procedure, and during follow up (one day after, 2 weeks, 1 month, 2 months and 3 months) after implantation of phakic IOL anterior chamber. All results were analyzed statistically using SPSS 16 statistics software. Correlation between parameter were analyzed using the wilcoxon test. Results: Median IOP before surgery were 14.00 mmHg (IOP), during follow up 17.00 mmHg (IOP I), 16.00 mmHg (IOP II) , 17.00 mmHg (IOP III), 15.00 mmHg (IOP IV), 15.00 mmHg (IOP V). The increasing of IOP between pre surgery and follow up a day after was found to correlate significantly (p=0.03), there were increasing of IOP after 2 weeks, a month, 2 and 3 months but no significant difference. Conclusion: There were significant of increasing IOP before surgery compare to a day after surgery,then the pattern of increasing IOP tend to be stable. There were no significant increasing of IOP during 3 months follow up.


2013 ◽  
Vol 13 (2) ◽  
pp. 33-41
Author(s):  
Devendra Maheshwari ◽  
Rengappa Ramakrishanan ◽  
Mohideen Abdul Kader ◽  
Neelam Pawar ◽  
Ankit Gupta

Aim: To evaluate the effect of phacoemulsification with intraocular lens implantation in eyes with pre-existing trabeculectomy.Methods: This prospective single-center clinical study evaluated intraocular pressure in 60 eyes of 60 patients who underwent phacoemulsification and implantation of a foldable intraocular lens after a previous successful trabeculectomy. Patients who had a trabeculectomy more than one year prior to the study were included. Intraocular pressure, number of antiglaucoma medications, bleb appearance, and visual acuity were recorded preoperatively, and at each follow-up examination and 12 months after phacoemulsification.Results: The mean intraocular pressure before phacoemulsification was 12.42 mmHg (SD, 4.60 mmHg), which increased to 14.98 mmHg (SD, 4.18 mmHg), 14.47 mmHg (SD, 3.58 mmHg), 15.44 mmHg (SD, 3.60 mmHg), and 15.71 mmHg (SD, 3.47 mmHg) after one, three, six, and 12 months, respectively. At each follow-up visit, the mean IOP was significantly higher than the preoperative value (p < 0.001, p = 0.015, p ≤ 0.001, and p = 0.001 at month one, three, six, and 12, respectively). The mean preoperative best-corrected visual acuity was 0.98 logMAR (SD, 0.44 logMAR) and the mean postoperative best-corrected visual acuity at 12 months was 0.20 logMAR (SD, 0.21 logMAR) [p = 0.0001]. The mean preoperative number of antiglaucoma medications used was 0.57 (SD, 0.63), which increased to 0.65 (SD, 0.63 ), 0.70 (SD, 0.72 ) 0.68, (SD, 0.70), and 0.67 (SD, 0.77 ) at one, three, six, and 12 months, respectively, but there were no statistically significant differences. Bleb size decreased clinically after phacoemulsification. Nineteen of 60 eyes (32%) developed fibrosis of bleb with decreased bleb size.Conclusion: Phacoemulsification with intraocular lens implantation significantly increased intraocular pressure and increased the number of antiglaucoma medications in eyes with pre-existing functioning filtering blebs.


2014 ◽  
Vol 2014 ◽  
pp. 1-5 ◽  
Author(s):  
Ana Ellen Queiroz Santiago ◽  
Adriana Machado Issy ◽  
Rioko Kimiko Sakata

Objectives. The aim of this study was to assess the effects of clonidine on intraoperative analgesia, sedation, intraocular and blood pressure, arrhythmia, and ischemia.Methods. Forty patients undergoing cataract surgery were allocated into two groups. They were monitored with Holter machine, the pupil was dilated, and 30 minutes later, 20 patients received clonidine (4 µg/kg), while the other 20 patients were given a 0.9% saline intravenously. Twenty minutes later, 2% lidocaine gel was applied. There were assessed intraoperative analgesia, intraocular pressure, blood pressure, heart rate, and the occurrence of arrhythmias and myocardial ischemia.Results. Pain intensity was lower in G1 during the phacoemulsification, irrigation, aspiration, and intraocular lens implantation. The HR and BP were lower with clonidine. The IOP was lower with clonidine after 15 minutes and at the end of the surgery. Sedation was higher with clonidine. The incidence of arrhythmia was lower at the end of surgery with clonidine. The incidence of myocardial ischemia did not differ between the groups.Conclusions. Clonidine (4 µg/kg) before a phacoemulsification reduced the intensity of pain during cataract surgery. It also induced sedation, reduction of BP, HR, and incidence of arrhythmia at the end of the surgery, and did not alter myocardial ischemia. This trial is registered with Clinicaltrials.govNCT01677351.


1998 ◽  
Vol 24 (11) ◽  
pp. 1515-1520 ◽  
Author(s):  
Tatsu Sawada ◽  
Wataru Kimura ◽  
Tohru Kimura ◽  
Hideki Suga ◽  
Akitoshi Ohte ◽  
...  

Cornea ◽  
2011 ◽  
Vol 30 (6) ◽  
pp. 720-723 ◽  
Author(s):  
Nienke Visser ◽  
Sacha T J M Gast ◽  
Noël J C Bauer ◽  
Rudy M M A Nuijts

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Wei Wei ◽  
Xueqing Yu ◽  
Lu Yang ◽  
Chan Xiong ◽  
Xu Zhang

Abstract Background With the rapid development of intraocular collamer lens (ICL) operation, it is foreseeable that we will encounter a large number of glaucoma patients with ICL implantation history. However, our current understanding of the treatment of glaucoma patients with ICL is limited. Hence we report a rare case of refractory glaucoma after intraocular collamer lens and intraocular lens implantation in a patient who underwent unsuccessful transscleral cyclophotocoagulation, which led to intraocular collamer lens displacement, angle closure and uncontrolled intraocular pressure. Case presentation A 39-year-old woman presented with intractably elevated intraocular pressure in the right eye. Since her intraocular collamer lens implantation surgery in 2017, her intraocular pressure had remained over 40 mmHg while using 3 types of anti-glaucoma medications. The patient had a history of phacoemulsification and posterior chamber phakic intraocular lens implantation for complicated cataracts secondary to uveitis in 2006. On gonioscope examination, there were signs of pigment dispersion, and the anterior chamber angle was open. Ultrasound biomicroscopy examination showed contact and rubbing between the intraocular collamer lens and posterior surface of the iris. And typical advanced glaucomatous optic neuropathy and visual field defects were observed. Transscleral cyclophotocoagulation was performed to control the intraocular pressure and prevent further visual field loss. However, the intraocular collamer lens was displaced after transscleral cyclophotocoagulation, which resulted in formation of a shallow anterior chamber 1 week later, angle closure and loss of intraocular pressure control 1 month later, even though the maximum dose of anti-glaucoma medication was used. Finally, an Ahmed glaucoma valve was successfully implanted in her anterior chamber, and the glaucoma was controlled, as observed at the 10-month follow-up. Conclusions Pigment dispersion is a common phenomenon after intraocular collamer lens implantation and may accelerate the progression of glaucoma. Transscleral cyclophotocoagulation should be carefully considered in glaucoma patients with elevated intraocular pressure after intraocular collamer lens implantation, given that transscleral cyclophotocoagulation may cause intraocular collamer lens displacement.


Sign in / Sign up

Export Citation Format

Share Document