Single Phase Inverter System using Proportional Resonant Current Control

Author(s):  
K.C. Chen ◽  
S. Salimin ◽  
S. A. Zulkifli ◽  
R. Aziz

<span>This paper presents the harmonic reduction performance of proportional resonant (PR) current controller in single phase inverter system connected to nonlinear load. In the study, proportional resonant current controller and low pass filter is discussed to eliminate low order harmonics injection in single phase inverter system. The potential of nonlinear load in producing harmonics is showed and identified by developing a nonlinear load model using a full bridge rectifier circuit. The modelling and simulation is done in MATLAB Simulink while harmonic spectrum results are obtained using Fast Fourier Transfor. End result show PR current controller capability to overcome the injection of current harmonic problems thus improved the overall total harmonic distortion (THD).</span>

2019 ◽  
Vol 8 (4) ◽  
pp. 2814-2822

This paper projects a high performance decoupled current control using a dq synchronous reference frame for single-phase inverter. For the three-phase inverter the conversion from AC to DC with Proportional Integral controller grants to obtain steady state error for AC Voltages and currents but has a few challenges with the single-phase systems. Hence, an orthogonal pair (β) is created by shifting the phase by one quarter cycle with respect to the real component (α) which is needed for the transformation from stationary to rotating frame. The synchronous reference frame control theory helps in controlling the AC voltage by using DC signal as the reference with the proportional integrator controllers. The implementation of the control is done with two-stage converter with LCL filter for a single-phase photovoltaic system. A modified MPPT Incremental conductance algorithm along with decoupled current control helps in regulating the active and reactive power infused into the grid where the power factor is improved, the efficiency of the system is increased above 95% and total harmonic distortion for current is also reduced to3%. The results have been validated using MATLAB.


2014 ◽  
Vol 989-994 ◽  
pp. 3231-3235
Author(s):  
Zhao Xia Zhou ◽  
Jia En Huang

This paper designs a single-phase inverter.Battery as a 12V DC input, and output for the 24V,50 HZ standard AC wave. The load is resistive.The power supply adopts the Boost booster and two full-bridge inverter transform. For the control circuit, the preceding Boost converter using tl494 chip control closed-loop feedback and for the inverter part, adopting the 6N137 to finish the optical coupling isolation.Then,through the DSP (TMS320F2812) to complete the output of SPWM modulation.And the modulated SPWM signal can drive chip IR211 conducting the full bridge inverter. Finally, through a low-pass filter output the standard sine AC inverter power.


Author(s):  
Md. Imran Azim ◽  
S. M. Mohiuddin

<p>This paper portrays an approach of an analysis that provides information regarding the presence of harmonics at the inverter output terminal. It is certainly true that harmonics cause unbalance and excessive neutral currents, interference in nearby communication networks and disturbance to other consumers. More importantly, torque pulsations in electric motor drives are caused by them. Thus, the minimization of the harmonics contained in the output of a single phase current controlled inverter undergoing hysteresis modulation technique is important so as to get rid of these detrimental effects. A model of an LC low pass filter has been provided in this paper for harmonics reduction purpose, as it blocks the harmonics and passes approximately a sinusoidal output. Moreover, the paper contains the method of Fast Fourier Transform (FFT) for fulfilling the desire of understanding not only the fundamental component but also the harmonics component flawlessly. It has been found from the simulation that the Total Harmonic Distortion (THD) in ideal case is 0%. On the other contrary, during the presence of harmonics, it steeps to 41.415% that can be mitigated to 0.0092% by implementing an LC low pass filter in a precise manner.</p>