Is the 99th Percentile the Optimal Reference Limit to Diagnose Myocardial Infarction With High-Sensitivity Cardiac Troponin Assays in Patients With Chronic Kidney Disease?

Circulation ◽  
2015 ◽  
Vol 131 (23) ◽  
pp. 2029-2031 ◽  
Author(s):  
Bernard R. Chaitman
Author(s):  
Brunilda Alushi ◽  
Fabian Jost-Brinkmann ◽  
Adnan Kastrati ◽  
Salvatore Cassese ◽  
Massimiliano Fusaro ◽  
...  

Background: Patients with severe chronic kidney disease (CKD G4-G5) often have chronically elevated high-sensitivity cardiac troponin T (hs-cTnT) values above the 99th percentile of the upper reference limit. In these patients, optimal cutoff levels for diagnosing non-ST-elevation acute cor-onary syndrome (NSTE-ACS) requiring revascularization remain undefined. Methods: Of 11,912 patients undergoing coronary angiography from 2012 to 2017 for suspected NSTE-ACS, 325 (3%) had severe CKD. Of these, 290 with available serial hs-cTnT measurements were included and 300 matched patients with normal renal function were selected as a control cohort. Results: Diagnostic performance for patients with severe CKD was high at presentation and similar to that of the control population (AUC, 95% CI: 0.81, 0.75-0.87 versus 0.85, 0.80-0.89, p=0.68) and the ROC-derived cutoff value at presentation was 4 times higher compared to the conventional 99th percentile. Combining the ROC-derived cutoff levels for hs-cTnT at presentation and absolute 3-hour changes, sensitivity increased to 98%, PPV and NPV improved up to 93% and 86%, re-spectively. (4) Conclusions: In patients with severe CKD and suspected ACS the diagnostic accu-racy of hs-cTnT for the diagnosis of NSTE-ACS requiring revascularization is improved by using higher assay specific cutoff levels combined with early absolute changes.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Daijin Ren ◽  
Tianlun Huang ◽  
Xin Liu ◽  
Gaosi Xu

Abstract Background Chronic kidney disease (CKD) are associated with acute myocardial infarction (AMI). High-sensitive cardiac troponin (hs-cTn) has been evidenced to enhance the early diagnostic accuracy of AMI, but hs-cTn levels are often chronically elevated in CKD patients, which reduces their diagnostic utility. The aim of this study was to derive optimal cutoff-values of hs-cTn levels in patients with CKD and suspected AMI. Methods In this retrospective paper, a total of 3295 patients with chest pain (2758 in AMI group and 537 in Non-AMI group) were recruited, of whom 23.1% were had an estimated glomerular filtration rate (eGFR) of < 60 mL min−1 (1.73 m2)−1. Hs-cTnI values were measured at presentation. Results AMI was diagnosed in 83.7% of all patients. The optimal value of hs-TnI in diagnosing AMI was 1.15 ng mL−1, which were higher in males than females comparing different cutoff-values of subgroups divided by age, gender and renal function, and which increased monotonically with decreasing of eGFR because in patients with CKD without AMI, the correlation between hs-cTnI and renal function is low but significant (r2 = 0.067, P < 0.001). Conclusions Different optimal cutoff-values of hs-cTnI in the diagnosis of AMI in patients with CKD were helpful to the clinical diagnosis of AMI in various populations and were higher in males than females, but which was needed to be validated by multicenter randomized controlled clinical studies in the future.


2018 ◽  
Vol 33 (suppl_1) ◽  
pp. i170-i171
Author(s):  
Waleed Elrefaey ◽  
Mohamed H Abou Freikha ◽  
Kamal M Okasha ◽  
Medhat M Ashmawy ◽  
Heba A Mourad ◽  
...  

Author(s):  
RA Jones ◽  
J Barratt ◽  
EA Brettell ◽  
P Cockwell ◽  
RN Dalton ◽  
...  

Background Patients with chronic kidney disease often have increased plasma cardiac troponin concentration in the absence of myocardial infarction. Incidence of myocardial infarction is high in this population, and diagnosis, particularly of non ST-segment elevation myocardial infarction (NSTEMI), is challenging. Knowledge of biological variation aids understanding of serial cardiac troponin measurements and could improve interpretation in clinical practice. The National Academy of Clinical Biochemistry (NACB) recommended the use of a 20% reference change value in patients with kidney failure. The aim of this study was to calculate the biological variation of cardiac troponin I and cardiac troponin T in patients with moderate chronic kidney disease (glomerular filtration rate [GFR] 30–59 mL/min/1.73 m2). Methods and results Plasma samples were obtained from 20 patients (median GFR 43.0 mL/min/1.73 m2) once a week for four consecutive weeks. Cardiac troponin I (Abbott ARCHITECT® i2000SR, median 4.3 ng/L, upper 99th percentile of reference population 26.2 ng/L) and cardiac troponin T (Roche Cobas® e601, median 11.8 ng/L, upper 99th percentile of reference population 14 ng/L) were measured in duplicate using high-sensitivity assays. After outlier removal and log transformation, 18 patients’ data were subject to ANOVA, and within-subject (CVI), between-subject (CVG) and analytical (CVA) variation calculated. Variation for cardiac troponin I was 15.0%, 105.6%, 8.3%, respectively, and for cardiac troponin T 7.4%, 78.4%, 3.1%, respectively. Reference change values for increasing and decreasing troponin concentrations were +60%/–38% for cardiac troponin I and +25%/–20% for cardiac troponin T. Conclusions The observed reference change value for cardiac troponin T is broadly compatible with the NACB recommendation, but for cardiac troponin I, larger changes are required to define significant change. The incorporation of separate RCVs for cardiac troponin I and cardiac troponin T, and separate RCVs for rising and falling concentrations of cardiac troponin, should be considered when developing guidance for interpretation of sequential cardiac troponin measurements.


2021 ◽  
pp. emermed-2020-210812
Author(s):  
Rob Meek ◽  
Louise Cullen ◽  
Zhong Xian Lu ◽  
Arthur Nasis ◽  
Lisa Kuhn ◽  
...  

BackgroundHigh-sensitivity cardiac troponin I (hs-cTnI) assays promise high diagnostic accuracy for myocardial infarction (MI). In an ED where conventional cTnI was in use, we evaluated an assessment pathway using the new Access hsTnI assay.MethodsThis retrospective analysis recruited ED patients with suspected MI between June and September 2019. All patients received routine care with a conventional cTnI assay (AccuTnI +3: limit of detection (LoD) 10 ng/L, 99th centile upper reference limit (URL) 40 ng/L, abnormal elevation cut-point 80 ng/L). Arrival, then 90-minute or 360-minute cTnI levels for low and non-low risk patients, respectively (ED Assessment of Chest pain score) guided diagnosis and disposition which was at treating physician discretion. The same patients had arrival and 90-minute or 180-minute samples drawn for hs-cTnI levels (Access hsTnI: LoD 2 ng/L, 99th centile URL 10 ng/L (females) and 20 ng/L (males); abnormal elevation above the URL and delta >30%). Treating physicians were blinded to the hs-cTnI results. Using the hs-cTnI values, investigators retrospectively assigned likely diagnosis, disposition and likelihood of a 30-day major adverse cardiac event (MACE). Admission was recommended for significantly rising hs-cTnI elevations. The primary objective was to demonstrate an acceptable unexpected 30-day post-discharge MACE rate of <1%. cTnI elevation rates, diagnostic outcomes and ED disposition were also compared between pathways.ResultsFor the 935 patients, unexpected 30-day post-discharge MACE rates were 0/935 (0%, 95% CI 0% to 0.4%) with the conventional or novel pathway. For the high-sensitivity and conventional assays, respectively, abnormal elevation rates were 29% (95% CI 26% to 32%) and 19% (95% CI 17% to 22%), for MI were 9% (95% CI 8% to 11%) and 8% (95% CI 6% to 10%), and for hospital admission were 42% (95% CI 39% to 45%) and 43% (95% CI 40% to 47%).ConclusionThe novel pathway using the Access hsTnI assay has an acceptably low 30-day MACE rate.


BMJ Open ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. e052004
Author(s):  
Alexander Dietl ◽  
Martina E Zimmermann ◽  
Caroline Brandl ◽  
Stefan Wallner ◽  
Ralph Burkhardt ◽  
...  

ObjectiveEuropean guidelines recommended a uniform upper reference limit of high-sensitivity cardiac troponin T (hsTnT) to rule out non-ST segment elevation myocardial infarction. Our study aimed to provide a hsTnT reference distribution and to assess the specificity of the 14 ng/L cut-off value in the mobile population ≥70 years of age.DesignA cross-sectional analysis was performed in the German AugUR study (Altersbezogene Untersuchungen zur Gesundheit der University of Regensburg).SettingStudy population was the mobile population aged 70+ years living in the city and county of Regensburg, Germany.ParticipantsA random sample was derived from the local population registries of residence. Of the 5644 individuals invited, 1133 participated (response ratio=20.1%). All participants came to the study centre and were mentally and physically mobile to conduct the protocol (face-to-face interview, blood draw and standardised transthoracic echocardiography). None of the participants was in an acute state of myocardial infarction.ResultsAmong the 1129 individuals with hsTnT measurements (overall median=10.0 ng/L(25th, 75th percentile)=(7.0, 15.0 ng/L)), hsTnT was higher among the older individuals and higher among men (men 70–74 years median=9.6 ng/L (7.2, 13.1 ng/L); men 90–95 years median=21.2 ng/L (14.6, 26.0 ng/L); women 70–74 years median=6.3 ng/L (4.7, 8.7 ng/L); and women 90–95 years median=18.0 ng/L (11.0, 21.0 ng/L)). In participants with impaired kidney function (eGFRcrea <60 mL/min/1.73 m2), hsTnT was elevated (median=13.6 ng/L (9.4, 20.6 ng/L)).Specificity of recommended upper reference limit, 14 ng/L, is 68%. Most false positives were among men aged >79 years (specificity=34%). In a healthy subgroup (n=96, none of the following: overt heart disease, impaired renal function, blood pressure >160/100 mm Hg, left ventricular hypertrophy and diastolic/systolic dysfunction), specificity was 90%.ConclusionIn the elderly population without acute myocardial infarction, hsTnT further increases with age showing different levels for men and women. The specificity of the 14 ng/L cut-off is considerably lower than 99%, even in healthy subjects.


Sign in / Sign up

Export Citation Format

Share Document