Utilization and Efficacy of Resuscitation Endpoints in Trauma and Burn Patients: A Review Article

2021 ◽  
pp. 000313482110604
Author(s):  
Miguel Belaunzaran ◽  
Shahm Raslan ◽  
Aleeza Ali ◽  
Kevin Newsome ◽  
Mark McKenney ◽  
...  

Shock is a sequelae in trauma and burn patients that substantially increases the risk for morbidity and mortality. The use of resuscitation endpoints allows for improved management of these patients, with the potential to prevent further morbidity/mortality. We conducted a review of the current literature on the efficacy of hemodynamic, metabolic, and regional resuscitation endpoints for use in trauma and burn patients. Hemodynamic endpoints included mean arterial pressure (MAP), heart rate (HR), urinary output (UO), compensatory reserve index (CRI), intrathoracic blood volume, and stroke volume variation (SVV). Metabolic endpoints measure cellular responses to decreased oxygen delivery and include serum lactic acid (LA), base deficit (BD), bicarbonate, anion gap, apparent strong ion difference, and serum pH. Mean arterial pressure, HR, UO, and LA are the most established markers of trauma and burn resuscitation. The evidence suggests LA is a superior metabolic endpoint marker. Newer resuscitation endpoint technologies such as point-of-care ultrasound (PoCUS), thromboelastography (TEG), and rotational thromboelastometry (ROTEM) may improve patient outcomes; however, additional research is needed to establish the efficacy in trauma and burn patients. The endpoints discussed have situational strengths and weaknesses and no single universal resuscitation endpoint has yet emerged. This review may increase knowledge and aid in guideline development. We recommend clinicians continue to integrate multiple endpoints with emphasis on MAP, HR, UO, LA, and BD. Future investigation should aim to standardize endpoints for each clinical presentation. The search for universal and novel resuscitation parameters in trauma and burns should also continue.

Medicina ◽  
2021 ◽  
Vol 57 (2) ◽  
pp. 187
Author(s):  
Dorothee Boehm ◽  
Henrik Menke

Fluid management is a cornerstone in the treatment of burns and, thus, many different formulas were tested for their ability to match the fluid requirements for an adequate resuscitation. Thereof, the Parkland-Baxter formula, first introduced in 1968, is still widely used since then. Though using nearly the same formula to start off, the definition of normovolemia and how to determine the volume status of burn patients has changed dramatically over years. In first instance, the invention of the transpulmonary thermodilution (TTD) enabled an early goal directed fluid therapy with acceptable invasiveness. Furthermore, the introduction of point of care ultrasound (POCUS) has triggered more individualized schemes of fluid therapy. This article explores the historical developments in the field of burn resuscitation, presenting different options to determine the fluid requirements without missing the red flags for hyper- or hypovolemia. Furthermore, the increasing rate of co-morbidities in burn patients calls for a more sophisticated fluid management adjusting the fluid therapy to the actual necessities very closely. Therefore, formulas might be used as a starting point, but further fluid therapy should be adjusted to the actual need of every single patient. Taking the developments in the field of individualized therapies in intensive care in general into account, fluid management in burn resuscitation will also be individualized in the near future.


2017 ◽  
Vol 2017 ◽  
pp. 1-3
Author(s):  
Scott LaTulip ◽  
Rameshwar R. Rao ◽  
Alan Sielaff ◽  
Nik Theyyunni ◽  
John Burkhardt

Morel-Lavallée lesions are uncommon injuries that can be associated with significant comorbidities if not detected early. Rapid diagnosis in the Emergency Department could significantly improve patient outcomes. We describe the diagnosis of such a lesion through the use of ultrasound imaging in the Emergency Department to utilize a fast, cost-effective imaging technique that does not subject the patient to radiation exposure. Our patient received surgical consultation but improved with conservative management. Ultrasound findings associated with this lesion do not require specialized equipment and should be considered when evaluating soft tissue lesions using point of care ultrasound.


CJEM ◽  
2020 ◽  
Vol 22 (3) ◽  
pp. 271-272
Author(s):  
David Barbic ◽  
Tom Jelic ◽  
Jordan Chenkin ◽  
Claire Heslop ◽  
Paul Atkinson

2007 ◽  
Vol 16 (4) ◽  
pp. 336-346 ◽  
Author(s):  
Teresita Lacara ◽  
Caroline Domagtoy ◽  
Donna Lickliter ◽  
Kathy Quattrocchi ◽  
Lydia Snipes ◽  
...  

Background Blood for point-of-care analysis of glucose levels is often obtained from different sources (fingerstick, arterial or central venous catheter). Objectives To examine agreement between point-of-care and laboratory glucose values and to determine effects of hematocrit, serum carbon dioxide, and mean arterial pressure on the accuracy of point-of-care values. Methods Point-of-care values were compared with laboratory values. In 49 critically ill patients, blood was obtained first from a catheter for laboratory testing and then from the catheter and via fingerstick for point-of-care testing. Bias, precision, and root-mean-square differences were calculated to quantify differences in values between the 2 methods. A t test was used to determine differences in values between each point-of-care blood source and the laboratory value. Multiple regression analysis was used to determine if serum level of carbon dioxide, hematocrit, and/or mean arterial pressure significantly contributed to the difference in bias and precision for the point-of-care blood sources. Results Mean laboratory glucose level was 135 (SEM 5.3, range 58–265) mg/dL. In point-of-care testing, bias ± precision and root-mean-square differences were 2.1 ± 12.3 and 12.35, respectively, for fingerstick blood and 0.6 ± 10.6 and 10.46 for catheter blood. Values for point-of-care and laboratory tests did not differ significantly. For catheter samples, hematocrit and serum carbon dioxide contributed significantly to difference scores between point-of-care and laboratory values (P < .001). Conclusions Glucose values for point-of-care samples did not differ significantly from laboratory values. For catheter samples, hematocrit and serum carbon dioxide levels accounted for the difference between point-of-care and laboratory glucose values.


2017 ◽  
Author(s):  
C Reissfelder ◽  
T Mees ◽  
S Schölch ◽  
A Remer ◽  
A Seifert ◽  
...  

POCUS Journal ◽  
2018 ◽  
Vol 3 (1) ◽  
pp. 13-14
Author(s):  
Hadiel Kaiyasah, MD, MRCS (Glasgow), ABHS-GS ◽  
Maryam Al Ali, MBBS

Soft tissue ultrasound (ST-USS) has been shown to be of utmost importance in assessing patients with soft tissue infections in the emergency department or critical care unit. It aids in guiding the management of soft tissue infection based on the sonographic findings.


POCUS Journal ◽  
2017 ◽  
Vol 2 (2) ◽  
pp. 15-17
Author(s):  
Rimi Sambi, MD ◽  
Heather Sawula, MD ◽  
Brent Wolfrom, MD ◽  
Joseph Newbigging, MD

As point of care ultrasound (PoCUS) becomes increasingly popular and a standard of care in many clinical settings, the interest for integration in medical undergraduate curriculum is also growing [1]. This project aims to assess whether formal bedside Focused Abdominal Scan for Trauma (FAST) exam training of medical students increases their knowledge and comfort with the use of bedside ultrasound in a family medicine setting at Queen’s University. Third year medical students (n=18) were recruited to participate in a training session involving a 1-hour online video and 2-hour hands-on session. Knowledge based surveys were completed before and after the training. A survey was completed 4 months after the teaching session evaluating knowledge retention, comfort, and application of skills. Student knowledge of PoCUS and FAST increased and was maintained (pre-training 56%±20%, post-training 82%±10%, p<0.001). Self-evaluation of comfort performing a FAST examination (5-point Likert scale) similarly increased post-training session (pre-training 1.4±0.8, post-training 3.8±0.9, p<0.005), but decreased 4 months later (3±1.2, p<0.005). Students in this study were unanimously interested in ultrasound training and the methods used effectively increased theoretical knowledge and comfort with use. Students did not retain their comfort levels with FAST exam 4 months after the training session, nor did they have the opportunity to utilize the skills learned. Further evidence is required to identify the applicability of these results to undergraduate curriculum development.


Sign in / Sign up

Export Citation Format

Share Document