The Kim Test

2005 ◽  
Vol 33 (8) ◽  
pp. 1188-1192 ◽  
Author(s):  
Seung-Ho Kim ◽  
Jun-Sic Park ◽  
Woong-Kyo Jeong ◽  
Seong-Kee Shin

Background Detection of a posteroinferior labral lesion by physical examination is often difficult. Purpose To introduce a novel diagnostic test for detecting a posteroinferior labral lesion of the shoulder. Hypothesis The Kim test can detect a posteroinferior labral lesion of the shoulder. Study Design Cohort study (diagnosis); Level of evidence, 1. Methods In 172 painful shoulders, the Kim test was compared with the jerk test and was verified by arthroscopic examination. A sudden onset of posterior shoulder pain and click with or without clunk indicated a positive test result. Results Thirty-three shoulders had a positive Kim test result, in which 24 had a posteroinferior labral lesion and 9 had a normal posteroinferior labrum. Of 139 shoulders with a negative Kim test result, 6 had a posteroinferior labral tear and 133 had a normal posteroinferior labrum. The sensitivity of the Kim test was 80%, specificity was 94%, positive predictive value was 0.73, and negative predictive value was 0.96. The interexaminer reliability between 2 examiners was 0.91. The accuracy of the jerk test in detecting a posteroinferior labral lesion was the following: sensitivity, 73%; specificity, 98%; positive predictive value, 0.88; and negative predictive value, 0.95. The location of the posterior labral lesion was predominantly posterior in 19 shoulders and predominantly inferior in 11 shoulders. The Kim test was more sensitive in detecting a predominantly inferior labral lesion, whereas the jerk test was more sensitive in detecting a predominantly posterior labral lesion. The sensitivity in detecting a posteroinferior labral lesion increased to 97% when the 2 tests were combined. Conclusion The Kim test is a reliable diagnostic test for detection of a posteroinferior labral lesion.

Medicina ◽  
2021 ◽  
Vol 57 (5) ◽  
pp. 503
Author(s):  
Thomas F. Monaghan ◽  
Syed N. Rahman ◽  
Christina W. Agudelo ◽  
Alan J. Wein ◽  
Jason M. Lazar ◽  
...  

Sensitivity, which denotes the proportion of subjects correctly given a positive assignment out of all subjects who are actually positive for the outcome, indicates how well a test can classify subjects who truly have the outcome of interest. Specificity, which denotes the proportion of subjects correctly given a negative assignment out of all subjects who are actually negative for the outcome, indicates how well a test can classify subjects who truly do not have the outcome of interest. Positive predictive value reflects the proportion of subjects with a positive test result who truly have the outcome of interest. Negative predictive value reflects the proportion of subjects with a negative test result who truly do not have the outcome of interest. Sensitivity and specificity are inversely related, wherein one increases as the other decreases, but are generally considered stable for a given test, whereas positive and negative predictive values do inherently vary with pre-test probability (e.g., changes in population disease prevalence). This article will further detail the concepts of sensitivity, specificity, and predictive values using a recent real-world example from the medical literature.


2018 ◽  
Vol 11 (3) ◽  
pp. 843-849 ◽  
Author(s):  
I. Wayan Sudarsa ◽  
Elvis Deddy Kurniawan Pualillin ◽  
Putu Anda Tusta Adiputra ◽  
Ida Bagus Tjakra Wibawa Manuaba

Background: Thyroid carcinoma generally has a good prognosis. The main focus of current research on thyroid carcinoma is to increase the accuracy of preoperative diagnosis of thyroid nodules. When the result of fine needle aspiration biopsy (FNAB) is indeterminate, clinicians often have doubts in determining the surgical management. Objective: Protein BRAF expression analysis can help improve the accuracy of FNAB and optimize the management of differentiated thyroid carcinoma. Methods: This study is a diagnostic test performed from October 2016 at Sanglah General Hospital with 38 patients as subjects who fulfilled the inclusion criteria. Data is being presented in descriptive form before diagnostic test is done to determine sensitivity, specificity, positive predictive value, negative predictive value and the accuracy of immunocytochemistry test for BRAF on indeterminate thyroid nodule. Results: Thirty-eight samples met the inclusion criteria during the study period. Three samples were male (7.9%) and 35 samples (92.1%) were female. The mean age of the sample was 45.21 years (SD ±10.910 years) with ages ranging from 23 to 66 years. Of the 12 samples undergoing isthmolobectomy, 7 samples (58.4%) were determined to be malignant from histopathological results. The sensitivity value of BRAF immunocytochemistry test is 45.45% with a specificity value of 81.25%, a positive predictive value of 76.92%, a negative predictive value of 52% and an accuracy of 60.50%. Analysis of the receiver operator (ROC) curve shows the area under the curve (AUC) of 63.4% with a confidence interval of 45.5–81.2%. Conclusion: Immunocytochemistry BRAF test have a reliable diagnostic value and can be taken into consideration in the preoperative diagnosis of thyroid malignancies.


2018 ◽  
Vol 8 (3) ◽  
pp. 139-142
Author(s):  
Mashah Binte Amin ◽  
Tarana Yasmin ◽  
Khaleda Parvin Rekha ◽  
Rushaida Haque Leeba ◽  
Nasima Akhter ◽  
...  

Background: Fibrocystic breast condition is a common, non-cancerous condition that affects premenopausal woman between 20 and 50 years of age. Because of non-specific nature of clinical presentation, diagnosis is not that easy. Linear array sonography has been helpful for detection of mammary dysplasia.Objective: The purpose of this study was to determine the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of superficial sonography in the diagnosis of chronic cystic mastitis.Materials and Methods: This study was carried out in department of Radiology & Imaging of Enam Medical College and Hospital during June 2013 to October 2017. Sonography was done in 1350 women suspected of having fibrocystic disease. Among them FNAC was done only in 1020 cases. Ultrasonographic findings and histopathological reports were analyzed using SPSS 13.0.Results: According to our study the sensitivity of superficial sonography was 92.4%, specificity 88.8%, positive predictive value 93.8%, negative predictive value 86.4% and accuracy 91% in the diagnosis of fibrocystic changes.Conclusion: With the validity test result, it can be concluded that high frequency sonography provides an accurate diagnosis of fibroadenosis.J Enam Med Col 2018; 8(3): 139-143


2020 ◽  
Vol 7 (1) ◽  
pp. e000355 ◽  
Author(s):  
Rohit Hariharan ◽  
Mark Jenkins

BackgroundCirculating tumour DNA from colorectal cancer (CRC) is a biomarker for early detection of the disease and therefore potentially useful for screening. One such biomarker is the methylated SEPT9 (mSEPT9) gene, which occurs during CRC tumourigenesis. This systematic review and meta-analysis aims to establish the sensitivity, specificity and accuracy of mSEPT9 tests for the early diagnosis of CRC.MethodsA systematic search of the relevant literature was conducted using Medline and Embase databases. Data were extracted from the eligible studies and analysed to estimate pooled sensitivity, specificity and diagnostic test accuracy.ResultsBased on 19 studies, the pooled estimates (and 95% CIs) for mSEPT9 to detect CRC were: sensitivity 69% (62–75); specificity 92% (89–95); positive likelihood ratio 9.1 (6.1–13.8); negative likelihood ratio 0.34 (0.27–0.42); diagnostic OR 27 (15–48) and area under the curve 0.89 (0.86–0.91). The test has a positive predictive value of 2.6% and negative predictive value of 99.9% in an average risk population (0.3% CRC prevalence), and 9.5% (positive predictive value) and 99.6% (negative predictive value) in a high-risk population (1.2% CRC prevalence).ConclusionThe mSEPT9 test has high specificity and moderate sensitivity for CRC and is therefore a potential alternative screening method for those declining faecal immunochemical test for occult blood (FIT) or other screening modalities. However, it is limited by its poor diagnostic performance for precancerous lesions (advanced adenomas and polyps) and its relatively high costs, and little is known about its acceptability to those declining to use the FIT.


2015 ◽  
Vol 40 (3) ◽  
pp. 89-91 ◽  
Author(s):  
N Ali ◽  
NC Nath ◽  
R Parvin ◽  
A Rahman ◽  
TM Bhuiyan ◽  
...  

This cross sectional study was carried out in the department of gastroenterology, BIRDEM, Dhaka from January 2010 to May 2011 to determine the role of ascitic fluid ADA and serum CA-125 in the diagnosis of clinically suspected tubercular peritonitis. Total 30 patients (age 39.69±21.26, 18M/12F) with clinical suspicion of tuberculosis peritonitis were included in this study after analyzing selection criteria. Laparoscopic peritoneal biopsy with ‘histopathological diagnosis’ was considered gold standard against which accuracics of two biomarkers (ADA & CA-125) were compared. Cut off value of ADA and CA-125 are 24 u/l, 35 U/ml respectively. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of ADA as a diagnostic modality in tuberculos peritonitis were 87.5%, 83.33%, 95.45%, 62.5% and 86.67% respectively where as CA-125 was found to have 83.33% sensitivity, 50% specificity, 86.9% positive predictive value, 42.85% negative predictive value and 76.6% accuracy. Both biomarkers are simple, non-invasive, rapid and relatively cheap diagnostic test where as laparoscopy is an invasive procedure, costly & requires trained staff and not without risk and also not feasible in all the centre in our country. So ascitic fluid ADA and serum CA-125 are important diagnostic test for peritoneal tuberculosis.Bangladesh Med Res Counc Bull 2014; 40 (3): 89-91


2016 ◽  
Vol 27 (2) ◽  
pp. 20-22
Author(s):  
Md Naushad Ali ◽  
Rehana Parvin ◽  
Md Abul Kalam Azad ◽  
AKM Mazharul Islam

This cross sectional study was carried out in the department of gastroenterology, Rangpur Medical College Hospital, Rangpur from January 2014 to July 2014 to compare between Invasive & Non-Invasive Diagnostic Evaluation of Tuberculosis Peritonitis In our prospective in clinically suspected patients. Total 30 patients (age 39.69±21.26, 18M/12F) with clinical suspicion of peritoneal tuberculosis were included in this study after analyzing selection criteria. Laparoscopic peritoneal biopsy with 'histopathological' diagnosis was considered as gold standard against which accuracies non-invasive test of two biomarkers (ADA & CA-125) were compared. Cut off value of ADA and CA-125 is 24 U/l, 35 U/ml respectively. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of ADA as a diagnostic modality in peritoneal tuberculosis were 87.5%, 83.33%, 95.45%, 62.5% and 86.67% respectively whereas CA-125 was found to have 83.33% sensitivity, 50% specificity, 86.9% positive predictive value, 42.85% negative predictive value and 76.6% accuracy. Both biomarkers were simple, non-invasive, rapid and relatively cheap diagnostic test whereas laparoscopy was an invasive procedure, costly & requires trained staff and not without risk and also not feasible in the entire centre in our country. So ascitic fluid ADA and serum CA-125 was important non-invasive diagnostic test for peritoneal tuberculosis.Medicine Today 2015 Vol.27(2): 20-22


2021 ◽  
Vol 5 (2) ◽  
pp. 215-230
Author(s):  
Widayat Widayat ◽  
Andi Friadi ◽  
Hafni Bacthiar

Introduction : Placenta accreta is defined as abnormal implantation of placenta villi which invades myometrium without the presence of decidua bacalis resulting in placenta that is difficult to remove. Based on the depth of invasion, placenta accreta is divided into three grades, placenta accreta, placenta increta, and placenta percreta. Placenta accreta developes if chorionic villi attaches to endometrium beyond desidua basalis. Placenta increta develops when chorionic villi invades the whole myometrium. Placenta percreta developes when chorionic villi attaches beyond myometrium reaching serous and abdominal organ. Based on clinical manifestation, placenta accreta is the common term being used. Incident of abnormal placenta invasion varies from 1 : 93.000 up to 1 : 540 pregnancy. PA incidence had increased four times from 1994 to 2002 in line with increased of caesarean section procedure. Other study showed history of caesarean section increased risk of placenta accreta up to 8,7 times. Placenta accreta index (PAI) was developed based on scoring process or various parameters assessment to help diagnose placenta accreta. The parameters including: history of caesarean section ≥ 2 times, lacunae grade, sagittal smallest myometrial thickness, anterior placenta previa and birding vessel. High PAI indicates high risk of abnormal placenta invasion based on histology.Objective : This study aims to investigate modified history of cesarean section score in placenta accreta index in predicting placenta accreta diagnosis in RSUP DR M  Djamil Padang.Material and methods : This was analytical study with cross sectional design. Study population was 84 placenta accreta patients in RSUP Dr. M. Djamil Padang from 2016 to 2019. Study sample was recruited using simple random sampling technique after meeting inclusion and exclusion criteria. Statistic analysis was done using Cohen’s Kappa test. Diagnostic test including sensiticivy, specivicity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy.Result : Strenght of agreement diagnosis placenta accreta based on PAI showed Kappa score of -0,002 (Kappa score < 0,2) which indicated  poor strength of agreement. Strenght of agreement diagnosis placenta accreta based on modified PAI showed Kappa score of 0,353 (Kappa score range from 0,21 to 0,40) which indicated fair strength of agreement. PAI diagnostic test yield sensitivity of 97,1%, specificity of 2,8%, positive predictive value of 48,5%, negative predictive value of 50%, and accuracy of 48,6%. Modified PAI diagnostic test yield sensitivity of 97,1%, specificity of 38,9%, positive predictive value of 60%, negative predictive value of 93,3%, and accuracy of 67,1%.Conclusion : PAI has high sensitivity, low specificity, moderate positive predictive value, moderate negative predictive value, and moderate accuration. Modified PAI has high sensitivity, moderate specificity, moderate positive predictive value, high negative predictive value, and high accuracy. PAI diagnosis has poor strength of agreement compared with pathology anatomy. Modified PAI diagnosis has fair strength of agreement compared with pathology anatomy. Modified PAI has identical sensitivity with standard PAI, meanwhile for specificity, positive predictive value, negative predictive value, and accuracy, modified PAI yields higher result compared to PAI.Keywords: Modified score of history caesarean section, placenta accreta index, Modified placenta accreta index, diagnostic test of placenta accreta diagnosis


2011 ◽  
Vol 5 (6) ◽  
pp. 250 ◽  
Author(s):  
Lambok Siahaan

Penelitian ini dilakukan untuk membandingkan penggunaan Rapid diagnostic test dengan pemeriksaan mikroskopik (apusan darah) dalam menegakkan diagnosis malaria. Penelitian uji diagnostik ini dilakukan di Kabupaten Nias Selatan dan Kotamadya Sabang, Sumatera Utara. Apusan darah diwarnai dengan larutan Giemsa 10% dan dibaca oleh pemeriksa yang sudah terlatih. Rapid diagnostic test dilakukan dengan menggunakan parascreen. Uji diagnostik rapid diagnostic test secara umum diperoleh hasil yaitu sensitivitas 63,8%; spesifisitas 100%; Positive Predictive Value (PPV) 100%; dan negative predictive value (NPV)93,5%. Kepadatan parasit pada rapid diagnostic test (+) dan mikroskopik (+) adalah 1.483 ± 583 parasit/μl. Sementara, kepadatan parasit pada pemeriksaan rapid diagnostic test (-) dan mikroskopik (+) adalah 621 ± 335 parasit/μl. Pemeriksaan mikroskopik masih lebih baik dibandingkandengan rapid diagnostic test, terutama pada kepadatan parasit yang rendah. Kata kunci: Malaria, pemeriksaan mikroskopik, rapid diagnostic testAbstractThe study was conducted to compare rapid diagnostic test with microscopy (blood film) to diagnose malaria disease. This diagnostic test was done in South of Nias District and Sabang District, North Sumatera. Blood film were colored with Giemsa 10% solution and examined by trained microscopists. Rapid Diagnostic Test was done based on the manual procedure. The results of diagnostic test of rapid diagnostic test were sensitivity 63,5%; specificity 100%, positive predictive value (PPV) 100%, and negative predictive value (NPV) 93,5%. The density of parasite in rapid diagnostic test (+) were 1.483 + 583 parasite/μl (1.120-2.920 parasite/μl. In other hand, the density of parasite in rapid diagnostic test (-) and microscopy were 621 + 335 parasite/ μl (120-1.160 parasite/μl). Microscopy still better than rapid diagnostic test, especially in patient with low parasite density. Keywords: Malaria, microscopic examination, rapid diagnostic test


2020 ◽  
Vol 5 (2) ◽  
pp. 167-171
Author(s):  
Rachmi Fauziah Rahayu ◽  
Luths Maharina ◽  
Yuyun Yueniwati

Background: Ultrasonography (USG) is still the first imaging modality for initial examination in patients with obstructive jaundice. Abdominal ultrasonography is quite good in seeing the morphology of the biliary tract, although the diagnostic etiological sensitivity of various causes of obstruction is very low. Magnetic resonance cholangio pancreatography (MRCP) is a new technique and can show the same picture as ERCP examination and no contrast media is needed. Aim: Aim for this study is knowing the results of ultrasound diagnostic tests in detecting Obstruction jaundice which was confirmed by the results of MRCP examination at Dr. Moewardi public hospital. Method: This study uses a diagnostic test that assesses sensitivity, big specifications, negative predictive value and positive predictive value of ultrasound in detecting jaundice obstruction confirmed by the results of the MRCP examination. Sampling was done by purposive sampling, on 68 research subjects. Results: This study show the characteristics of jaundice in the form of stones with sensitivity and specificity values ​​of 84% and 83%, positive predictive value 75% and negative predictive value 90% and in biliary tract tumors 83% and 84%, positive predictive value 75% and predictive value negative 90%. Conclusions: Ultrasound has a high sensitivity and specificity value in diagnosing obstructive jaundice in the case of biliary tract stones and biliary tract tumors


2015 ◽  
Vol 2 (4) ◽  
pp. 162-166 ◽  
Author(s):  
Annette M. Molinaro

Abstract When a patient receives a positive test result from a diagnostic test they assume they have the disease. However, the positive predictive value (PPV), ie the probability that they have the disease given a positive test result, is rarely equal to one. To assist their patients, doctors must explain the chance that they do in fact have the disease. However, physicians frequently miscalculate the PPV as the sensitivity and/or misinterpret the PPV, which results in increased anxiety in patients and generates unnecessary tests and consultations. The reasons for this miscalculation as well as three ways to calculate the PPV are reviewed here.