Seismic performance of FRP-reinforced concrete-filled thin-walled steel tube considering local buckling

2018 ◽  
Vol 37 (9) ◽  
pp. 592-608 ◽  
Author(s):  
CY Zhu ◽  
YH Zhao ◽  
L Sun

The objective of this study is to investigate the seismic performance of fiber-reinforced polymer-reinforced concrete-filled thin-walled steel tube (CFTST). Twelve specimens with different fiber-reinforced polymer types (glass fiber-reinforced polymer and carbon fiber-reinforced polymer) and reinforcing modes were tested under constant axially compressive load and cyclic lateral load. The failure mode and lateral load versus displacement relationship for each specimen were recorded during testing. The strength, ductility, and energy dissipation capacity were analyzed accordingly. Further, a stress–strain relationship and a restoring force model of the fiber-reinforced polymer confining steel tube with local buckling were proposed. A hysteretic model for the fiber-reinforced polymer-reinforced CFTST was developed subsequently. The results indicate that the seismic performance of fiber-reinforced polymer-reinforced CFTST can be effectively improved by optimizing the fiber-reinforced polymer type and corresponding reinforcing scheme. Carbon fiber-reinforced polymer and glass fiber-reinforced polymer are suitable materials for the confinement and bending reinforcement of the column, respectively. The modeling results show the energy imported into the column is mainly dissipated by the thin-walled steel tube. The energy dissipation proportion of the steel tube, concrete core, and longitudinal fiber-reinforced polymer are >80%, 10%–20%, and <8%, respectively. The energy dissipation value of the steel tube can be improved more than 40% after effectively restraining the local buckling.

2015 ◽  
Vol 11 (1) ◽  
pp. 23
Author(s):  
Elfania Bastian ◽  
Rendy Thamrin ◽  
Jafril Tanjung

Dalam studi ini dilakukan analisis numerik tentang pengaruh perkuatan dengan pelat CFRP (Carbon Fiber Reinforced Polymer) terhadap tegangan tulangan tarik. Tegangan pada tulangan tarik ditinjau pada daerah sekitar perletakan balok sederhana dengan dua tumpuan. Untuk maksud tersebut serangkaian model numerik dipersiapkan dengan jenis tulangan yang berbeda. Dimana panjang penyaluran tambahan divariasikan 100mm dan 250mm. Tulangan yang digunakan adalah tulangan baja dan GFRP (Glass Fiber Reinforced Polymer). Hasil analisis menjelaskan bahwa perkuatan dengan pelat CFRP dapat meningkatkan kapasitas balok dimana tegangan yang diterima oleh tulangan tarik menurun. Disamping itu tulangan tarik GFRP juga terbukti efektif meningkatkan daktilitas balok beton bertulang.


BUILDER ◽  
2021 ◽  
Vol 286 (5) ◽  
pp. 28-33
Author(s):  
Renata Kotynia ◽  
Konrad Szczepański

W artykule przedstawiono obliczeniową analizę nośności dwuprzęsłowych belek ze zbrojeniem kompozytowym z włókien szklanych i węglowych (Glass Fiber Reinforced Polymer – GFRP; Carbon Fiber Reinforced Polymer – CFRP) opracowaną na podstawie wybranych wytycznych normowych: Fib Bulletin 40, japońskiej – JSCE, amerykańskiej – ACI 440 oraz kanadyjskiej – ISIS z wynikami wybranych badań doświadczalnych. Głównym celem pracy jest określenie wpływu redystrybucji momentów przy obliczaniu nośności belek dwuprzęsłowych. Wyniki uproszczonej analizy obliczeniowej (bez wpływu redystrybucji momentów) pozwoliły porównać różne podejścia normowe oraz określić poziom zgodności wyników obliczeniowych z wynikami doświadczalnymi. W ten sposób można oszacować zakres bezpieczeństwa nośności na zginanie określony wpływem redystrybucji momentów względem wyników badań doświadczalnych.


2019 ◽  
Vol 275 ◽  
pp. 02010 ◽  
Author(s):  
Xing-yu SONG ◽  
Qin HOU ◽  
Lei CHEN

In order to improve the seismic performance of common concrete shear wall with concealed bracings, fiber reinforced polymer modified concrete instead of ordinary concrete was applied to the shear wall as described in this paper. In this paper, the experimental study on the seismic performance of two different types of shear walls under cyclic loading was carried out, and also the failure characteristics, bearing capacity, ductility, hysteretic curve, stiffness attenuation and energy dissipation performance of the proposed shear wall were analyzed systematically. The test results show that the seismic performance of fiber-reinforced polymer modified concrete shear wall is significantly improved because its the damping ratio, deformation capacity and energy dissipation capacity are greatly improved compared with ordinary concrete shear wall with concealed bracings, which ensures its better stiffness stability in the later stage.


2020 ◽  
Vol 39 (15-16) ◽  
pp. 599-612
Author(s):  
Gabriel Y Fortin ◽  
Elsayed A Elbadry ◽  
Atsushi Yokoyama

This article presents an experimental study on the quasi-static crushing performance of carbon fiber reinforced polymer (CFRP) rods consisting of unidirectional carbon fibers wrapped by braided glass fibers. Rods with and without a taper are tested and then inserted in extruded and expanded polystyrene foam and cardboard panels. Hybrid columnar aluminum tube–CFRP rod structures are also tested in all panel materials. These results are compared to those based on glass fiber reinforced polymer (GFRP) rods, GFRP rods in polystyrene foams, and to GFRP rods in cardboard from a previous study. Tapered CFRP rods exhibit progressive crushing behavior with specific energy absorption superior to GFRP rods, with values of 82 kJ/kg and 65 kJ/kg, respectively. Moreover, the highest specific energy absorption (111 kJ/kg) is obtained in hybrid columnar aluminum tube–CFRP tapered rods, exceeding values of aluminum tubes (89 kJ/kg) and equivalent structures containing GFRP rods (102 kJ/kg). Within panels, cardboard produces the largest increase in mean load of CFRP and GFRP rods due to most constraining fiber splaying during crushing, followed by extruded foam, and lastly expanded foam. However, crushing displacement is most restricted in cardboard due to earlier final compaction. The smallest variations in crushing load occur in extruded polystyrene due to greater homogeneity throughout the foam structure.