Imaging modalities for midfacial fractures

Trauma ◽  
2017 ◽  
Vol 19 (3) ◽  
pp. 175-185
Author(s):  
Chaya M David ◽  
Ramya K Kastala ◽  
Namitha Jayapal ◽  
Shanila A Majid

The middle third of the facial skeleton is one of the most complex areas of the human body. A critical factor determining the successful treatment of midfacial fractures is an early and correct diagnosis. Assessment and management of the traumatized patient requires rapid evaluation and decision making. Imaging for the evaluation of patients with midfacial fractures has contributed to achieving an accurate diagnosis and a subsequent successful management. It requires a knowledge of those imaging modalities and projections that provide the most information with the least exposure of radiation to the patient. Conventional radiography has been used successfully for many years although advanced imaging methods such as—three-dimensional computed tomography, magnetic resonance imaging, and cone beam computed tomography have been applied more recently. In this article, we will take a relook at various modalities to image midfacial fractures, and discuss the rationale for selection of those procedures that offer the greatest diagnostic information.

2012 ◽  
Vol 23 (3) ◽  
pp. 179-191 ◽  
Author(s):  
Conor Durack ◽  
Shanon Patel

Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillo-facial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontics. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice.


2020 ◽  
Vol 5 (1) ◽  
Author(s):  
Ateksha Bhardwaj Khanna

Abstract Background Endodontic disease can adversely affect the quality of life and therefore early diagnosis and consequent timely treatment is of paramount importance for the Endodontist. Radiology is an essential component in treatment planning, disease monitoring and assessment of treatment outcome. Periapical radiographs and panoramic radiography are frequently utilised but they provide only two-dimensional representation of three-dimensional structures. The advent of cone beam computed tomography (CBCT) offers three-dimensional accuracy of the hard tissue images with a reasonable cost and this has revolutionised imaging of the dentomaxillofacial structures. This imaging system has been seen to overcome some limitations of conventional radiography, as brought out in this review. The improvement in the accuracy is, however, accompanied at the cost of increased radiation exposure to the patient. Nevertheless, smaller areas of exposure are normally appropriate for endodontic imaging, and adjustment in the exposure parameters can further moderate the effective dose (Loubele et al. 37(6):309-18, 2008). Aims and objectives The aim of this review is to present the pertinent literature on the various applications of cone beam computed tomography in the field of endodontics. Methods Literature was electronically searched on the following sources; Medline and Keats Library. Further, a manual search was performed on the following journals: International Endodontic Journal, Journal of Endodontics, Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, Endodontology, Journal of Dental Research, European Journal of Oral Sciences & Odontology and Dentomaxillofacial Radiology. A preliminary search was performed to gain an idea of the available literature using keywords ‘Cone Beam Computed Tomography’ to view the volume of the literature evident and identify questions to be addressed in this review. The initial search showed 243 potential articles. After scrutinising the titles and abstracts of the retrieved articles, 70 relevant studies were reviewed in full text. Furthermore, ‘published guidelines on the use of CBCT’ were also searched so as to include the results as an additional source material. All the articles eligible to be included in the review were in the English language and ranged from the year 1960 to the present. Also all the studies reviewed were based on the various uses of cone beam computed tomography in the field of endodontics. The keywords used to search were ‘Cone Beam Computed Tomography (CBCT)’, ‘Conventional radiography’, ‘Applications of CBCT in endodontics’, ‘CBCT and tooth morphology’, ‘CBCT and apical periodontitis’, ‘CBCT and vertical root fractures’, ‘CBCT and resorption’, ‘CBCT and pre-surgical assessment’, ‘CBCT and dento-alveolar trauma’ and ‘CBCT and endodontic outcome’. Results Every case is unique and CBCT should be considered only after studying each case individually. CBCT imaging needs to be adopted or used where information from conventional imaging systems is either inadequate for the management of endodontic problems or inconclusive. Having said that, it is safe to state that CBCT imaging has the potential to become the first choice for endodontic treatment planning and outcome assessment, especially when new scanners with lower radiation doses and enhanced resolution would be available.


2016 ◽  
Vol 73 (4) ◽  
pp. 305
Author(s):  
Alessandra Areas e Souza ◽  
Ingrid De Assis Mota Costa ◽  
Paula Mozer Vidal

Objective: The aim of this study was to conduct a literature review on the use of cone-beam computed tomography in periodontics and determine the extent and severity of periodontal lesions so as to encourage the development of a new concept for diagnosis and surgical planning in periodontics. Material and methods: A literature search was conducted in PubMed database using the following keywords: computed tomography, diagnosis periodontics, bone defects, furcation lesions, and periodontal biotype. A total of 33 articles were found. Results: A review of the articles suggested benefits in using this technology in periodontal surgical planning, for treatment of furcation lesions, bone defects, and determination of periodontal biotype. Conclusion: Cone-beam computed tomography three-dimensional images is superior to conventional radiography. It also minimizes patient exposure to ionizing radiation, optimizes surgical planning, and decreases operative time, leading to a better response to treatment. This technology is very useful in clinical practice, but is not used widely in periodontics. We believe that the use of this technology should be promoted among professionals.


2013 ◽  
Vol 5 (2) ◽  
pp. 52-55
Author(s):  
Prakash Lokhande ◽  
G.B SHIVAMURTHY ◽  
SAURAV KR SRIVASTAVA

ABSTRACT Cone beam computed tomography (CBCT) has been specifically designed to produce undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a significantly lower effective radiation dose compared with conventional computed tomography (CT). The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontics. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The aim of this paper is to review current literature on the applications and limitations of CBCT in the management of endodontic problems.


2020 ◽  
Vol 10 (14) ◽  
pp. 4961
Author(s):  
Quirin Döbelin ◽  
Bernd Stadlinger ◽  
Daniel B. Wiedemeier ◽  
Dominique Bichsel ◽  
Martin Rücker ◽  
...  

The present study aimed to compare the diagnostic reliability of a pre-set, manufacturer-specific, low-dose mode against a standard-dose mode in the detection of four different osseous lesions in the mandible with cone-beam computed tomography (CBCT). Four types of lesions (periapical lesion, extended periodontal gap, recession of the buccal lamella, sequestrum/fracture) were prepared on 40 pig mandibles. CBCT images were obtained from each mandible, with both the low-dose and standard-dose modes using the Orthophos SL CBCT device (Dentsply-Sirona, Bensheim, Germany). Twelve assessors quantitatively (detection of lesions) and qualitatively (assessment of detectability) evaluated the CBCT images in SIDEXIS 4 (Dentsply-Sirona) using a study-specific digital examination tool. A correct diagnosis was achieved in almost 71% (LD: 70.8%; SD: 70.9%) of 1920 lesions, without a statistically significant difference between the low-dose and standard-dose mode. This finding was consistent across all four lesion types. In conclusion, while low-dose mode and standard-dose mode CBCT scans performed similarly in the detection of four prepared lesions of the mandible, the former may be a promising, user-friendly alternative method of obtaining radiation-optimized, three-dimensional images in accordance with the As Low As Diagnostically Acceptable (ALADA) principle.


Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 757
Author(s):  
Maged Sultan Alhammadi ◽  
Abeer Abdulkareem Al-mashraqi ◽  
Rayid Hussain Alnami ◽  
Nawaf Mohammad Ashqar ◽  
Omar Hassan Alamir ◽  
...  

The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18–30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland–Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.


Sign in / Sign up

Export Citation Format

Share Document