Controlling combustion with negative valve overlap in a gasoline–diesel dual-fuel compression ignition engine

2015 ◽  
Vol 17 (3) ◽  
pp. 354-365 ◽  
Author(s):  
Kohei Kuzuoka ◽  
Takashi Kondo ◽  
Hirotsugu Kudo ◽  
Hiroyoshi Taniguchi ◽  
Hiroshi Chishima ◽  
...  
2019 ◽  
Vol 22 (1) ◽  
pp. 165-183 ◽  
Author(s):  
Oudumbar Rajput ◽  
Youngchul Ra ◽  
Kyoung-Pyo Ha ◽  
You-Sang Son

Engine performance and emissions of a six-stroke gasoline compression ignition engine with a wide range of continuously variable valve duration control were numerically investigated at low engine load conditions. For the simulations, an in-house three-dimensional computational fluid dynamics code with high-fidelity physical sub-models was used, and the combustion and emission kinetics were computed using a reduced kinetics mechanism for a 14-component gasoline surrogate fuel. Variation of valve timing and duration was considered under both positive valve overlap and negative valve overlap including the rebreathing of intake valves via continuously variable valve duration control. Close attention was paid to understand the effects of two additional strokes of the engine cycle on the thermal and chemical conditions of charge mixtures that alter ignition, combustion and energy recovery processes. Double injections were found to be necessary to effectively utilize the additional two strokes for the combustion of overly mixed lean charge mixtures during the second power stroke. It was found that combustion phasing in both power strokes is effectively controlled by the intake valve closure timing. Engine operation under negative valve overlap condition tends to advance the ignition timing of the first power stroke but has minimal effect on the ignition timing of second power stroke. Re-breathing was found to be an effective way to control the ignition timing in second power stroke at a slight expense of the combustion efficiency. The operation of a six-stroke gasoline compression ignition engine could be successfully simulated. In addition, the operability range of the six-stroke gasoline compression ignition engine could be substantially extended by employing the continuously variable valve duration technique.


Author(s):  
Seyfi Polat ◽  
Hamit Solmaz ◽  
Ahmet Uyumaz ◽  
Alper Calam ◽  
Emre Yılmaz ◽  
...  

Abstract In this study, the effects of negative valve overlap (NVO) on homogenous charge compression ignition (HCCI) combustion and engine performance were experimentally investigated. A four stroke, single cylinder, port injection HCCI engine was operated at −16 deg crank angle (CA), −8 deg CA, and +8 deg CA valve overlap values and different lambda values and engine speeds at wide open throttle. RON40 and RON60 were used as test fuels in view of combustion and performance characteristics in HCCI mode. The variations of indicated mean effective pressure (IMEP), residual gas, CA50, indicated thermal efficiency (ITE), indicated specific fuel consumption (ISFC), maximum pressure rise rate (MPRR) and ringing intensity (RI) were observed on HCCI combustion. The results showed that NVO caused to trap residual gases in the combustion chamber. Hot residual gases showed heating and dilution effect on HCCI combustion. Combustion was retarded with the presence of residual gas at −16 deg CA NVO. Test results showed that higher imep and maximum in-cylinder pressure were obtained with RON60 according to RON40. As expected, CA50 was obtained later with RON60 compared to RON40 due to more resistance of auto-ignition. RON60 residual gas prevented the rapid and sudden combustion due to higher heat capacity of charge mixture. RI decreased with the usage of RON60 compared to RON40. Significant decrease was seen on RI with RON60 especially at lower lambda values. It was seen that HCCI combustion can be controlled with NVO and operating range of HCCI engines can be extended.


2021 ◽  
pp. 146808742110183
Author(s):  
Jonathan Martin ◽  
André Boehman

Compression-ignition (CI) engines can produce higher thermal efficiency (TE) and thus lower carbon dioxide (CO2) emissions than spark-ignition (SI) engines. Unfortunately, the overall fuel economy of CI engine vehicles is limited by their emissions of nitrogen oxides (NOx) and soot, which must be mitigated with costly, resource- and energy-intensive aftertreatment. NOx and soot could also be mitigated by adding premixed gasoline to complement the conventional, non-premixed direct injection (DI) of diesel fuel in CI engines. Several such “dual-fuel” combustion modes have been introduced in recent years, but these modes are usually studied individually at discrete conditions. This paper introduces a mapping system for dual-fuel CI modes that links together several previously studied modes across a continuous two-dimensional diagram. This system includes the conventional diesel combustion (CDC) and conventional dual-fuel (CDF) modes; the well-explored advanced combustion modes of HCCI, RCCI, PCCI, and PPCI; and a previously discovered but relatively unexplored combustion mode that is herein titled “Piston-split Dual-Fuel Combustion” or PDFC. Tests show that dual-fuel CI engines can simultaneously increase TE and lower NOx and/or soot emissions at high loads through the use of Partial HCCI (PHCCI). At low loads, PHCCI is not possible, but either PDFC or RCCI can be used to further improve NOx and/or soot emissions, albeit at slightly lower TE. These results lead to a “partial dual-fuel” multi-mode strategy of PHCCI at high loads and CDC at low loads, linked together by PDFC. Drive cycle simulations show that this strategy, when tuned to balance NOx and soot reductions, can reduce engine-out CO2 emissions by about 1% while reducing NOx and soot by about 20% each with respect to CDC. This increases emissions of unburnt hydrocarbons (UHC), still in a treatable range (2.0 g/kWh) but five times as high as CDC, requiring changes in aftertreatment strategy.


2014 ◽  
Vol 18 (1) ◽  
pp. 205-216 ◽  
Author(s):  
Wojciech Tutak ◽  
Arkadiusz Jamrozik

The results of gasification process of dried sewage sludge and use of generator gas as a fuel for dual fuel turbocharged compression ignition engine are presented. The results of gasifying showed that during gasification of sewage sludge is possible to obtain generator gas of a calorific value in the range of 2.15 ? 2.59 MJ/m3. It turned out that the generator gas can be effectively used as a fuel to the compression ignition engine. Because of gas composition, it was possible to run engine with partload conditions. In dual fuel operation the high value of indicated efficiency was achieved equal to 35%, so better than the efficiency of 30% attainable when being fed with 100% liquid fuel. The dual fuel engine version developed within the project can be recommended to be used in practice in a dried sewage sludge gasification plant as a dual fuel engine driving the electric generator loaded with the active electric power limited to 40 kW (which accounts for approx. 50% of its rated power), because it is at this power that the optimal conditions of operation of an engine dual fuel powered by liquid fuel and generator gas are achieved. An additional advantage is the utilization of waste generated in the wastewater treatment plant.


Sign in / Sign up

Export Citation Format

Share Document