Piezoelectric matrix-assisted ionization

2018 ◽  
Vol 25 (2) ◽  
pp. 202-207 ◽  
Author(s):  
Bijay Banstola ◽  
Carson W Szot ◽  
Achala P Deenamulla Kankanamalage ◽  
Kermit K Murray

We have developed a new actuation method for matrix-assisted ionization with good temporal and spatial resolution using piezoelectric cantilever. A strike from the piezoelectric bimorph cantilever on a thin metal foil was used to remove materials deposited on the opposite side facing the mass spectrometer inlet. Highly charged ions of peptides and proteins were generated from dried droplet deposits and sampled into the inlet of the mass spectrometer. A lateral resolution of 1 mm was obtained with the piezoelectric sampling configuration. Singly charged lipids and gangliosides were detected from tissue with piezoelectric matrix-assisted ionization using a silica nanoparticle co-matrix.

Author(s):  
Iannis Dandouras ◽  
Philippe Garnier ◽  
Donald G Mitchell ◽  
Edmond C Roelof ◽  
Pontus C Brandt ◽  
...  

Titan's nitrogen-rich atmosphere is directly bombarded by energetic ions, due to its lack of a significant intrinsic magnetic field. Singly charged energetic ions from Saturn's magnetosphere undergo charge-exchange collisions with neutral atoms in Titan's upper atmosphere, or exosphere, being transformed into energetic neutral atoms (ENAs). The ion and neutral camera, one of the three sensors that comprise the magnetosphere imaging instrument (MIMI) on the Cassini/Huygens mission to Saturn and Titan, images these ENAs like photons, and measures their fluxes and energies. These remote-sensing measurements, combined with the in situ measurements performed in the upper thermosphere and in the exosphere by the ion and neutral mass spectrometer instrument, provide a powerful diagnostic of Titan's exosphere and its interaction with the Kronian magnetosphere. These observations are analysed and some of the exospheric features they reveal are modelled.


2004 ◽  
Vol 110 ◽  
pp. 325 ◽  
Author(s):  
P. Moretto-Capelle ◽  
A. Rentenier ◽  
D. Bordenave-Montesquieu ◽  
A. Bordenave-Montesquieu

1986 ◽  
Vol 40 (4) ◽  
pp. 434-445 ◽  
Author(s):  
M. A. Vaughan ◽  
G. Horlick

In inductively coupled plasma/mass spectrometry analyte, M may be distributed among several species forms including doubly charged ions (M2+), singly charged ions (M+), mono-oxide ions (MO+), and hydroxide ions (MOH+). Detailed data are presented for Ba to illustrate the dependence of the ion count of these species and their ratios (M2+/M+, MO+/M+, and MOH+/M+) on nebulizer flow rate, plasma power, and sampling depth. Although these data are representative of most elements, many form oxides to a much greater degree than Ba; data are presented for Ti, W, and Ce to illustrate this fact. These various analyte species are important in that serious interelement interferences can occur because of spectral overlap. An extensive pair of tables indicating potential spectral interferences caused by element oxide, hydroxide, and doubly charged ions is presented.


2022 ◽  
Author(s):  
Florian Trinter ◽  
Tsveta Miteva ◽  
Miriam Weller ◽  
Alexander Hartung ◽  
Martin Richter ◽  
...  

We investigate interatomic Coulombic decay in NeKr dimers after neon inner-valence photoionization [Ne+(2s-1)] using a synchrotron light source. We measure with energy resolution the two singly charged ions of the...


2018 ◽  
Vol 221 ◽  
pp. 04006
Author(s):  
Satoshi Sakamoto ◽  
Sanshiro Akaoka ◽  
Masaya Gemma ◽  
Yasuo Kondo ◽  
Kenji Yamaguchi ◽  
...  

The manufacturing costs of semiconductor products such as silicon wafers can be reduced by decreasing the kerf loss. In addition, a decrease in the kerf loss leads to an effective utilization of rare materials, which is environmentally beneficial from the viewpoint of saving resources. This study aims to reduce the kerf loss during slicing hard and brittle materials. Therefore, the possibility of using an extremely thin metal foil blade instead of a wire tool in slicing was examined. Initially, grooving characteristics using a metal foil blade (thickness: 50 μm or less) was investigated. The main conclusions are that grooving with a metal foil blade is possible and kerf loss can be reduced. The groove depth tends to increase as the machining time and particle size of abrasives increase. The groove width is smaller when a thin metal foil blade is used and vice versa. However, if the abrasive particle size is too large, grooving becomes impossible. Since the wear of metal foil blade increases with an increase in the particle size of the abrasive, it is necessary to use an abrasive with a particle size that is suitable for the thickness of the metal foil blade.


2019 ◽  
Vol 14 (01) ◽  
pp. C01009-C01009
Author(s):  
S.L. Bogomolov ◽  
A.E. Bondarchenko ◽  
A.A. Efremov ◽  
Yu.E. Kostyukhov ◽  
K.I. Kuzmenkov ◽  
...  

1981 ◽  
Vol 35 (4) ◽  
pp. 380-384 ◽  
Author(s):  
Robert S. Houk ◽  
Harry J. Svec ◽  
Velmer A. Fassel

Mass spectra have been obtained of species in the axial channel of an inductively coupled argon plasma by extracting ions from the inductively coupled plasma into a vacuum system housing a quadrupole mass spectrometer. Ionization temperatures ( Tion) are obtained from relative count rates of m/z-resolved ions according to two general types of ionization equilibrium considerations: (a) the ratio of doubly/singly charged ions of the same element, and (b) the ratio of singly charged ions from two elements of different ionization energy. The Tion values derived from measurement of Ar+2/Ar+, Ba+2/Ba+, Sr+2/Sr+, and Cd+/I+ are all greater than those expected from excitation temperatures measured by other workers. The latter three values for Tion are in reasonable agreement with values obtained by optical spectrometry for a variety of argon inductively coupled plasmas.


2015 ◽  
Vol 13 (1) ◽  
Author(s):  
Roxana M. Ghiulai ◽  
Mirela Sarbu ◽  
Constantin Ilie ◽  
Alina D. Zamfir

AbstractStructural analysis of long chain polysaccharides by electrospray ionization mass spectrometry (ESI-MS) is challenging since these molecules do not contain readily ionizable groups. Their mass spectra are dominated by singly charged ions, limiting the detection of high molecular weight species. Derivatization can enhance ionization, but analyte loss on purification decreases sensitivity. We report a method based on nanoESI-MS and MS/MS by collision induced dissociation (CID) for underivatized long chain polysaccharides. The procedure was tested on underivatized polydisperse dextrans (average molecular weight 4,000) at 2.6 kV ESI voltage and CID MS/MS at energies between 30-60 eV. 113 ions corresponding to species from Glc2 to Glc35 were detected. Ions at m/z 1,409.48, 1,107.35 and 1,438.47, assigned to [G17+2Na]2+,[G20+H+Na+K]3+ and [G35+2H+Na+K]4+, were sequenced and characterized by MS/MS. The component containing 35 Glc repeats is the longest polysaccharide chain detected by ESI-MS and structurally analyzed by MS/MS without prior derivatization and/or separation.