Can surgeons optimize range of motion and reduce scapulohumeral impingements in reverse shoulder arthroplasty? A computational study

2021 ◽  
pp. 175857322199414
Author(s):  
Marc-Olivier Gauci ◽  
Jean Chaoui ◽  
Julien Berhouet ◽  
Adrien Jacquot ◽  
Gilles Walch ◽  
...  

Background Early glenohumeral impingement leads to poor range of motion and notching in reverse shoulder arthroplasty. The aim was to find from planning software which implant configuration provides the best motions in reverse shoulder arthroplasty. Patients and Methods Reverse shoulder arthroplasty planning (Glenosys) was made in 31 patients (12 men, 19 women, 76 ± 6 yo) and impingements were analyzed. Inlay (155°-inclined) and Onlay (145°-inclined) humeral designs were tested. Four configurations were tested for each shoulder: “INLAY”: non-lateralized glenoid-inlay humerus, “BIO-INLAY”: lateralized glenoid (BIO-RSA)-inlay humerus, “ONLAY”: non-lateralized glenoid-onlay humerus, and “BIO-ONLAY”: lateralized (BIO-RSA) glenoid-onlay humerus. Results BIO-ONLAY and BIO-INLAY groups presented a significantly better result in all tested motion ( p < 0.001 for all tests). BIO-ONLAY allowed a significantly better external rotation, extension and adduction than BIO-INLAY with decreased impingements with the pilar. BIO-INLAY presented a significantly better abduction. In abduction, an abutment of the greater tuberosity against the acromion was associated with a lower range of motion ( p < 0.0001) and did not depend on the lateralization. Conclusion Glenoid lateralization delays the glenohumeral impingement in reverse shoulder arthroplasty and gives the best rotations, adduction and extension when associated with neutral inclination and humeral 145° inclination. Greater tuberosity abutment has to be avoided in abduction and the Inlay design provides the best abduction.

2020 ◽  
pp. 175857322091684
Author(s):  
Richard Dimock ◽  
Mohamed Fathi Elabd ◽  
Mohamed Imam ◽  
Mark Middleton ◽  
Arnaud Godenèche ◽  
...  

Background Reverse shoulder arthroplasty (RSA) has revolutionized the management of many shoulder pathologies. Lateralization has become favourable to combat complications (e.g. notching, compromised external rotation), using a metallic, or autogenous bone-graft baseplates – bony increased-offset reverse shoulder arthroplasty (BIO-RSA). We systematically reviewed the literature to determine: Does BIO-RSA improve range of motion and outcome scores? Are notching rates decreased? Does the graft heal? Methods All available prospective studies, trials and case series reporting on BIO-RSA were included. Outcomes were grouped into outcome scores, range of motion and radiographic outcomes. Data were pooled and statistical analysis performed. Results Eight studies reported on 385 RSA – 235 BIO-RSA and 150 standard-RSA (STD-RSA). Follow-up was 20–36 months; average age 74 years. Outcome scores: Constant-Murley and SSV scores showed statistically significant post-operative benefit of BIO-RSA (mean-difference 4.0 (95% confidence interval (CI): 0.79,7.1) and 6.8 (95% CI: 3.8, 9.9)). No Minimal Clinically Importance Difference was surpassed. Range of motion: No difference was found in any direction. Notching: Notching was less likely with BIO-RSA (odds ratio 0.19 (95% CI: 0.10, 0.38)). Healing and loosening: 92% grafts fully healed/incorporated. Loosening rate was 2.4%. Conclusions Literature on BIO-RSA is limited with only one randomised controlled trial (RCT). Weak evidence exists for improved outcome scores. Range of motion is equivocal. Notching rates are significantly lower in BIO-RSA. The graft usually heals.


2020 ◽  
pp. 175857322093623
Author(s):  
Georges Haidamous ◽  
Alexandre Lädermann ◽  
Robert U Hartzler ◽  
Bradford O Parsons ◽  
Evan S Lederman ◽  
...  

Background The purpose was to evaluate the relationship of component size and position to postoperative range of motion following reverse shoulder arthroplasty. The hypothesis was that increased lateralization, larger glenospheres, and a decreased acromiohumeral distance would be associated with excellent postoperative range of motion. Methods A retrospective multicenter study was performed at a minimum of one year postoperatively on 160 patients who underwent primary reverse shoulder arthroplasty with a 135° humeral component. Outcomes were stratified based on postoperative forward flexion and external rotation into excellent ( n = 42), defined as forward flexion >140° and external rotation > 30°, or poor ( n = 36), defined as forward flexion <100° and external rotation < 15°. Radiographic measurements and component features were compared between the two groups. Results A larger glenosphere size was associated with an excellent outcome ( p = 0.009). A 2-mm posterior offset humeral cup ( p = 0.012) and an increased inferior glenosphere overhang (3.1 mm vs 1.4 mm; p = 0.002) were also associated with excellent outcomes. Humeral lateralization and distalization were not associated with an excellent outcome. Conclusion: Larger glenosphere size and inferior positioning as well as posterior humeral offset are associated with improved postoperative range of motion following reverse shoulder arthroplasty. Level of Evidence Level 3, retrospective comparative study.


2021 ◽  
Vol 8 ◽  
Author(s):  
Shu-Kun He ◽  
Jing-Ping Liao ◽  
Jin-Hai Guo ◽  
Fu-guo Huang

Introduction: Reverse shoulder arthroplasty (RSA) is becoming popular in the treatment of complex proximal humeral fractures (PHFs). Greater tuberosity healing may influence functional outcomes and range of motion (ROM) of shoulder after RSA. In addition, the design of prosthesis may impact the healing rate of greater tuberosity. The purpose of this study is to know: (1) does the healing of greater tuberosity affect the functional outcomes and ROM of shoulder? and (2) does the design of prosthesis affect the healing rate of greater tuberosity?Materials and Methods: PubMed, Ovid/Embase, and the Cochrane Library were searched for studies comparing the clinical outcomes between the healed groups and the non-healed groups after RSA.Results: For functional outcomes, the results showed that the healed group had better Constant scores (CSs) (p &lt; 0.0001). For ROM, the healed group showed better flexion (p &lt; 0.0001), abduction (p = 0.02), and external rotation (p &lt; 0.00001) of shoulder. For the design of prosthesis, the mean healing rate of greater tuberosity (82.7%) in patients with fracture-dedicated prosthesis was higher than those (63.0%) in patients with standard prosthesis. Subgroup analyses showed that the CS (p = 0.12) and abduction (p = 0.96) of patients using fracture-dedicated prostheses were not different between the healed groups and the non-healed groups. Meta-regression showed that there was no significant relationship between the design of prosthesis and CS (p = 0.312), flexion (p = 0.422), or external rotation (p = 0.776).Conclusion: Our meta-analysis showed that the healed groups could obtain better functional outcomes and ROM than the non-healed groups. In addition, fracture-dedicated prostheses promoted the healing rate of greater tuberosity.Systematic Review Registration:https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42020157276, PROSPERO: CRD42020157276.


2018 ◽  
Vol 7 (8) ◽  
pp. 189
Author(s):  
Toru Ichiseki ◽  
Shusuke Ueda ◽  
Daisuke Souma ◽  
Miyako Shimasaki ◽  
Yoshimichi Ueda ◽  
...  

Synovial osteochondromatosis (SO) is a rare disease in which chondrometaplasia develops in the synovium of joints, bursa, and tendon sheaths. SO is found most frequently in the knee joint, while cases of SO developing in the shoulder joint are rare, accounting for only 1.9–5.2% of all SO cases. Moreover, most of these cases show secondary rather than primary involvement. In a patient with SO associated with extensive rotator cuff tearing and marked arthropathic changes, we performed mass resection and reverse shoulder arthroplasty (RSA), and obtained good pain relief and functional improvement. The patient was a 75-year-old woman who had developed left shoulder pain five years earlier without any known precipitating factor. The range of motion of the left shoulder showed extremely severe restriction, with flexion 80°, abduction 60°, and external rotation 0°, and prominent impingement symptoms. On plain radiographs and computed tomography (CT), prominent shoulder arthropathic changes were found. On plain magnetic resonance imaging (MRI), around the shoulder, an irregular hypointense region was identified in the center on T1-enhanced images, while hyperintense nodular lesions with a hypointense center were detected on T2-enhanced images. Since extensive rotator cuff tearing was also found, a diagnosis of OS associated with rotator cuff tearing and arthropathic changes was made. Surgery consisted of resection of a whitish mass-like floating body in the center of the joint followed by RSA. The postoperative course was uneventful, and one year postoperatively there was no recurrence of pain and the range of motion of the left shoulder had improved to flexion 140°, abduction 130°, and external rotation 30°. Moreover, no complications such as recurrence of osteochondromatosis, implant loosening, or infection were seen. On histopathological examination, the loose body was found to consist of a cartilage component and bone tissue with hyalinization. No findings indicative of malignancy were apparent, and since nodular cartilage arrangement was found, primary osteochondroma was diagnosed. These findings suggested that physical friction between the rotator cuff and the mass was the cause of the rotator cuff tearing, and that the extensive rotator cuff tearing accounted for the progression of the associated extremely severe arthropathic changes.


2021 ◽  
Vol 12 ◽  
pp. 215145932110199
Author(s):  
Georg Siebenbürger ◽  
Evi Fleischhacker ◽  
Johannes Gleich ◽  
Tobias Helfen ◽  
Wolfgang Böcker ◽  
...  

Background: The aim of this study was to evaluate the functional and radiographic outcome in patients with reverse total shoulder arthroplasty (RSA) for displaced proximal humeral fractures (PHF) with or without tenotomy of the supraspinatus tendon. Methods: Between June 2011 and June 2018, 159 patients (age >65 years) with a displaced proximal humeral fracture underwent reverse total shoulder arthroplasty (Grammont design) in a single-center study and were longitudinally followed up. In all cases, the tuberosities were attached to the prosthesis in a standardized procedure. Functional outcome, range of motion as well as tuberosity integration, resorption and displacement were assessed at final follow-up. Outcomes were compared between patients that underwent RSA in combination with tenotomy of the supraspinatus (ST) and patients that underwent RSA without supraspinatus tenotomy (NT). Results: At a mean follow up of 22.2 ± 16.4 months 76 patients (mean age 77.1 ± 7.2 years, 83% women) could be evaluated (follow-up rate 47.8%). There were no statistically significant differences between the ST (n = 29) and NT groups (n = 47) in tuberosity integration, resorption </≥50%, or displacement (p = 0.99/0.31/0.7/0.99). Functional outcome was better in ST group (Constant score 76.2 ± 5.9 vs. 64.5 ± 12.8; p < 0.05) especially regarding mean active external rotation (>20°: 65.5% vs. 14.9%, p < 0.05) and active abduction (>120°: 89.7% vs. 21.3%, p < 0.05). Tuberosity integration (ST and NT together: n = 34) showed better functional results than resorption or displacement (p < 0.05). Conclusions: Tenotomy of the supraspinatus tendon in RSA for displaced PHF leads to similar radiographic results regarding tuberosity integration, resorption and displacement but better functional outcome with regard to range of motion. Level of Evidence: III


2020 ◽  
Vol 29 (2) ◽  
pp. 347-354 ◽  
Author(s):  
Vani J. Sabesan ◽  
Diego J.L. Lima ◽  
Yang Yang ◽  
Matthew C. Stankard ◽  
Mauricio Drummond ◽  
...  

2020 ◽  
pp. 175857322092115
Author(s):  
Bradley S Schoch ◽  
Joseph J King ◽  
Joseph Zuckerman ◽  
Thomas W Wright ◽  
Chris Roche ◽  
...  

Background Anatomic total shoulder arthroplasty improves pain and function with a reported reoperation rate of approximately 1% per year. With improved glenoid fixation, reverse shoulder arthroplasty implants may outperform anatomic total shoulder arthroplasty. We evaluate the functional outcomes and reoperation rate of anatomic total shoulder arthroplasty versus reverse shoulder arthroplasty at a minimum eight-year follow-up or revision. Methods Between 2005 and 2010, 187 shoulders (137 anatomic total shoulder arthroplasty, 50 reverse shoulder arthroplasty) were retrospectively reviewed at a mean of 8.8 years. The mean age at surgery was 67 years. Females were more commonly treated with reverse shoulder arthroplasty. Both groups had similar body mass index and comorbidities. Outcome measures evaluated included abduction, forward elevation, external rotation, internal rotation, Simple Shoulder Test, Constant score, American Shoulder and Elbow Score, University of California Los Angeles Shoulder score, and Shoulder Pain and Disability Index. Results At follow-up, anatomic total shoulder arthroplasty demonstrated greater overhead range of motion and external rotation. All patient-reported outcomes remained similar between groups. Reverse shoulder arthroplasty patients were more likely to rate shoulders as much better or better after surgery (90% versus 67%, p = 0.004). Complications were observed in 24% of anatomic total shoulder arthroplasties and 8% of reverse shoulder arthroplasties (p = 0.02). Reoperation was more common in anatomic total shoulder arthroplasties (23% versus 4%, p = 0.003). Discussion At mid-to-long-term follow-up, reverse shoulder arthroplasties demonstrated significantly fewer complications and reoperations than anatomic total shoulder arthroplasties. Despite similar patient-reported outcomes, reverse shoulder arthroplasty patients were more likely to be satisfied with their shoulder.


2019 ◽  
Vol 101-B (4) ◽  
pp. 461-469 ◽  
Author(s):  
A. Lädermann ◽  
A. J. Schwitzguebel ◽  
T. B. Edwards ◽  
A. Godeneche ◽  
L. Favard ◽  
...  

Aims The aim of this study was to report the outcomes of different treatment options for glenoid loosening following reverse shoulder arthroplasty (RSA) at a minimum follow-up of two years. Patients and Methods We retrospectively studied the records of 79 patients (19 men, 60 women; 84 shoulders) aged 70.4 years (21 to 87) treated for aseptic loosening of the glenosphere following RSA. Clinical evaluation included pre- and post-treatment active anterior elevation (AAE), external rotation, and Constant score. Results From the original cohort, 29 shoulders (35%) were treated conservatively, 27 shoulders (32%) were revised by revision of the glenosphere, and 28 shoulders (33%) were converted to hemiarthroplasty. At last follow-up, conservative treatment and glenoid revision significantly improved AAE, total Constant score, and pain, while hemiarthroplasty did not improve range of movement or clinical scores. Multivariable analysis confirmed that conservative treatment and glenoid revision achieved similar improvements in pain (glenoid revision vs conservative, beta 0.44; p = 0.834) but that outcomes were significantly worse following hemiarthroplasty (beta -5.00; p = 0.029). Conclusion When possible, glenoid loosening after RSA should first be treated conservatively, then by glenosphere revision if necessary, and last by salvage hemiarthroplasty Cite this article: Bone Joint J 2019;101-B:461–469.