scholarly journals The effect of pulsed lavage irrigation on suture knot security

2020 ◽  
Vol 28 (1) ◽  
pp. 230949901988812
Author(s):  
Andrew Golz ◽  
Jonathan Yun ◽  
Nickolas Garbis ◽  
Dane Salazar

Purpose: The purpose of this study was to determine the effect of low-pressure and pulsed lavage irrigation on suture knot security. Methods: Ninety-tied suture loops were measured for baseline circumference and then subjected to no irrigation, bulb syringe irrigation, or pulsed lavage irrigation. The sutures were placed under a load and then measured for final circumference. A larger circumference difference indicated poorer knot security. Results: There was a statistically significant difference in the knot security between all three groups ( p < 0.001). Pulsed lavage resulted in the greatest circumference increase (0.52 ± 0.19 mm), followed by bulb syringe (0.24 ± 0.18 mm), and lastly no irrigation (0.08 ± 0.00 mm). None of the groups had any catastrophic failures. No knots met the predetermined criteria for knot failure. Conclusion: Pulsed lavage irrigation resulted in a statistically significant decrease in suture knot security as compared to bulb syringe irrigation and no irrigation. None of the groups met the currently accepted criteria for clinical suture failure, which has a relatively arbitrary value. While the available literature does not discuss increases in loop circumference for specific orthopedic applications, this small difference suggests that pulse lavage is unlikely to have a clinically significant impact on the suture integrity for most orthopedic procedures.

1989 ◽  
Vol 20 (2) ◽  
pp. 149-152 ◽  
Author(s):  
Kenneth W. Berger

Hearing aid gain usage by two groups of children was examined. No appreciable difference was noted between the groups, nor was there a clinically significant difference between gain usage by these children as compared with a sample of adult hearing aid wearers.


2020 ◽  
Vol 154 (Supplement_1) ◽  
pp. S163-S164
Author(s):  
K G Manjee ◽  
W G Watkin

Abstract Introduction/Objective Cervical biopsy is performed following an abnormal pap smear or positive HPV testing in an attempt to uncover clinically significant lesions [HSIL/invasive carcinoma (HSIL+)]. An excisional procedure is considered if biopsy confirms HSIL+. When preceded by pap smear of LSIL, ASCUS, NILM/HPV+ or persistent HPV, continued surveillance is recommended for biopsies showing no SIL or LSIL. In our laboratory, cervical biopsies are routinely sectioned at 3 levels. Deeper levels are often ordered when initial sections are non-diagnostic. p16 immunohistochemistry, with or without deeper levels, is often ordered to confirm HSIL, or to differentiate HSIL from mimics. In this study, we examine whether and in what clinical situations does obtaining additional levels uncover clinically significant lesions. Methods 430 cervical biopsies between January-May 2018, with recent cytology of LSIL, ASCUS or NILM/HPV+ were identified in the pathology database. HPV status (if known), final biopsy diagnosis and past history of LSIL/HSIL were recorded. For each biopsy, orders for additional levels and/or p16 immunohistochemistry were recorded resulting in 4 categories: C1-no additional levels or p16, C2-deeper only, C3-deeper+p16 and C4-p16 only. Final diagnoses were divided into HSIL+, LSIL and no SIL. Results There was no significant difference in prior history of LSIL/HSIL and HPV status between all categories. Biopsy results were as follows: HSIL+: 11/222 (5%) C1; 1/78 (1%) C2; 7/43 (16%) C3; 15/87 (17%) C4 LSIL: 91/222 (41%) C1; 7/78 (9%) C2; 16/43 (37%) C3; 35/87 (40%) C4 No SIL: 120/222 (54%) C1; 70/78 (90%) C2; 20/43 (46%) C3; 37/87 (42%) C4 The average number of additional levels in C2 and C3 was 3.8 and 1.8, respectively. Conclusion Deeper levels alone did not enhance the detection of HSIL+. Almost all LSIL/HSIL were detected when initial levels were diagnostic or suspicious and supported by p16 immunohistochemistry. 3 levels are adequate to detect clinically significant lesions.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
A Kempny ◽  
K Dimopoulos ◽  
A E Fraisse ◽  
G P Diller ◽  
L C Price ◽  
...  

Abstract Background Pulmonary vascular resistance (PVR) is an essential parameter assessed during cardiac catheterization. It is used to confirm pulmonary vascular disease, to assess response to targeted pulmonary hypertension (PH) therapy and to determine the possibility of surgery, such as closure of intra-cardiac shunt or transplantation. While PVR is believed to mainly reflect the properties of the pulmonary vasculature, it is also related to blood viscosity (BV). Objectives We aimed to assess the relationship between measured (mPVR) and viscosity-corrected PVR (cPVR) and its impact on clinical decision-making. Methods We assessed consecutive PH patients undergoing cardiac catheterization. BV was assessed using the Hutton method. Results We included 465 patients (56.6% female, median age 63y). The difference between mPVR and cPVR was highest in patients with abnormal Hb levels (anemic patients: 5.6 [3.4–8.0] vs 7.8Wood Units (WU) [5.1–11.9], P<0.001; patients with raised Hb: 10.8 [6.9–15.4] vs. 7.6WU [4.6–10.8], P<0.001, respectively). Overall, 33.3% patients had a clinically significant (>2.0WU) difference between mPVR and cPVR, and this was more pronounced in those with anemia (52.9%) or raised Hb (77.6%). In patients in the upper quartile for this difference, mPVR and cPVR differed by 4.0WU [3.4–5.2]. Adjustment of PVR required Conclusions We report, herewith, a clinically significant difference between mPVR and cPVR in a third of contemporary patients assessed for PH. This difference is most pronounced in patients with anemia, in whom mPVR significantly underestimates PVR, whereas in most patients with raised Hb, mPVR overestimates it. Our data suggest that routine adjustment for BV is necessary.


2009 ◽  
Vol 16 (4) ◽  
pp. 233-236 ◽  
Author(s):  
MSM Mark ◽  
TTS Au ◽  
YF Choi ◽  
TW Wong

Objectives To determine whether the minimum clinically significant difference (MCSD) in visual analogue scale (VAS) pain score varies with age, gender, education level and cause of pain (trauma versus non-trauma) in Chinese patients. Methods This was a prospective descriptive study of local Chinese patients 15 years of age or older who presented with pain to the accident & emergency department. On presentation, patients were asked to indicate their current pain severity with a single mark through a standard 100–mm visual analogue scale. Then they would be offered an analgesic for pain-relief. After 30–45 minutes, the patients were asked to give a verbal categorical rating of their pain as ‘a lot better’, ‘a little better’, ‘much the same’, ‘a little worse’, or ‘much worse’ and to mark the level of pain on a VAS of the same type as used previously. The MCSD in VAS pain score was defined as the mean difference between the current and preceding scores when the subject reported ‘a little worse’ or ‘a little better’ in pain. Data were compared based on gender, age, education level, and traumatic versus non-traumatic causes of pain. Results 186 patients were enrolled in the study, yielding 77 evaluable comparisons where pain was rated as ‘a little better’ or ‘a little worse’. Overall, the MCSD in VAS pain score in the group was 17 mm (95%CI 13.6 mm to 20.6 mm). There were statistically significant differences between the MCSD in VAS pain score between genders and causes of pain (trauma versus non-trauma). Conclusions The MCSD in VAS pain scores was found to be 17 mm. There was significant differences in MCSD in VAS pain score in different genders and between trauma and non-trauma cases.


PEDIATRICS ◽  
1993 ◽  
Vol 91 (4) ◽  
pp. 816-819
Author(s):  
Jeanne B. Funk ◽  
John B. Chessare ◽  
Michael T. Weaver ◽  
Anita R. Exley

Given that children with attention deficit hyperactivity disorder (ADHD) are more impulsive than peers, this study explored whether they are correspondingly more creative, and whether creativity declines when impulsivity is decreased through methylphenidate (Ritalin) therapy. A repeated-measures quasi-experimental design was used to compare the performance of 19 boys with previously diagnosed ADHD and 21 comparison boys aged 8 through 11 on two administrations of alternate forms of the Torrance Tests of Creative Thinking-Figural (nonverbal). Boys with ADHD received prescribed methylphenidate only for the first session. Overall, mean Torrance summary scores for comparison boys (mean = 115.1, SD = 16.1) were higher than for boys with ADHD (mean = 107.6, SD = 12.7). However, the difference between means was small (7%) and did not meet the 25% criterion for a clinically significant difference. No changes in performance over time (comparison group) or medication state (ADHD group) were observed. These data suggest that, when measured nonverbally, the creative thinking performance of boys with ADHD is not superior to that of peers who do not have ADHD. Regarding the effects of methylphenidate, prescribed therapy did not influence performance on this measure of creative thinking.


PEDIATRICS ◽  
1999 ◽  
Vol 104 (Supplement_5) ◽  
pp. 1031-1036
Author(s):  
Stephen F. Kemp ◽  
Judy P. Sy

National Cooperative Growth Study substudy VII was conducted 1) to compare standardized hand–wrist and knee bone age determinations in pubertal children treated with growth hormone (GH); 2) to compare local determinations of bone ages with centrally determined bone ages; 3) to relate the response to GH therapy to the bone age determinations; and 4) to ascertain the predictive value of each type of bone age determination. Eligible subjects were those in the National Cooperative Growth Study who were at Tanner pubertal stage 2 or greater for breasts (girls) or genitals (boys). Radiographs of the hand–wrist were taken annually, and radiographs of the knee were taken at the beginning and the end of the study. Separate bone age determinations were made from these radiographs. A combined hand–wrist and knee bone age determination also was derived. There were 990 patients in the study; in 925 (677 boys), there were both hand–wrist and knee bone age determinations from the baseline pubertal radiographs. There was only one radiographic assessment in 496 patients, two in 205 patients, and three to eight in the remaining patients. The strongest correlation was between the hand–wrist bone age and the hand–wrist plus knee bone age (r = .995). Also strongly correlated were knee with hand–wrist (r = .872) and knee with hand–wrist plus knee (r = .914). For none of these bone age methods was any statistically significant difference found between the methods. The locally determined bone ages correlated strongly with the centrally determined bone ages for knee (r = .850), hand–wrist (r = .928), and hand–wrist plus knee (r = .930); however, the locally determined knee and hand–wrist values were less (by ∼0.3 year) than the centrally determined values. These differences, however, do not appear to be clinically significant.


2018 ◽  
Vol 35 (05) ◽  
pp. 315-321
Author(s):  
Pobe Luangjarmekorn ◽  
Pravit Kitidumrongsook ◽  
Sittisak Honsawek

Background Microsuture is an essential material for basic microsurgical training. However, it is consumable, expensive, and sometimes unavailable in the microsurgical laboratory. To solve this problem, we developed a microsuture made from human hair and needle gauge. Methods Do-It-Yourself (DIY) microsuture is made from human hair and needle gauge 32G (BD Ultra-Fine Pen Needles 4 mm × 32G). Methods are explained step by step. This DIY microsuture (labeled as “test microsuture”) and nylon 8–0 (Ethilon suture 8–0, labeled as “standard microsuture”) were used for teaching orthopaedic residents to perform arterial anastomosis in chicken thighs. All residents practiced without knowing that “test microsuture” was made from the DIY method. After completing the training, quality of both microsutures was evaluated by questionnaire in topics of (1) thread quality (size, strength, elasticity, handing, knot perform, and knot security), (2) needle quality (size, curve, shape, sharpness, handling, and strength), (3) needle–thread interface (size, strength, and smoothness), and (4) overall quality of microsuture. Each category was evaluated by Likert score (5 = excellent, 4 = good, 3 = fair, 2 = poor, and 1 = very poor). Results The DIY microsuture was performed in three steps: (1) insert human hair into needle gauge by microforceps, (2) bend needle into smooth curve, and (3) disconnect needle and create needle–hair interface. The questionnaire was completed by 30 orthopaedic residents and showed that thread quality of DIY and standard microsuture had “good” and “good-to-excellent” quality (mean Likert score: 3.77–4.23 and 3.80–4.27, respectively, with no statistical difference). Thread–needle interface quality of DIY and standard microsuture also had “good” and “good-to-excellent” quality (Likert score: 3.73–4.20 and 4.07–4.33, respectively, with no statistical difference). Needle part of DIY microsuture had lower quality than standard suture (fair-to-good compared with good-to-excellence quality, score 3.30–3.67 vs. 4.20–4.27, respectively, with a statistically significant difference, p-value < 0.05). However, overall quality of DIY suture and standard microsuture had “good” and “good-to-excellent” (mean Likert score: 3.73 and 4.00, respectively, with no statistical difference). Conclusion The DIY microsuture from human hair and needle gauge could be an alternative for basic microsurgical training with lower cost, easy production, and more availability for use in practice with acceptable quality compared with that of standard microsuture.


2021 ◽  
Vol 8 ◽  
Author(s):  
ABDOUL Hafizou RABE ◽  
Fatima SALEK ◽  
Intissar El IDRISSI ◽  
Fatima ZAOUI ◽  
Hicham BENYAHIA

Abstract  Background: Our study aims to evaluate, through a systematic review, the reliability of numerical models compared to conventional models on the main parameters of orthodontic diagnosis  Method: four databases were consulted: PubMed; Google Scholar, Cochrane Library, and Ebscohost. The research included published studies since 2010, meta-analysis studies, randomized and non-randomized controlled trials, prospective and retrospective studies. Results: Among 3811 selected references, only five studies met our inclusion criteria. In the systematic review, there were statistical differences between the digital models and the plaster models. However, this difference is clinically acceptable. On the other hand, there are some limitations, relative to the types of the severity of the congestion, the elapsed time to digitize, and the numerical means. Conclusion: The results of our systematic review have shown that there is no clinically significant difference between the numerical and physical models for the majority of diagnostic parameters.


2006 ◽  
Vol 7 (3) ◽  
pp. 22-29
Author(s):  
Farah Masood ◽  
Christos Angelopoulos ◽  
Alan Glaros

Abstract Aim The purpose of this study was to compare two types of conventional radiographic film: Ekta-speed plus and Insight (Eastman Kodak Co, Rochester NY, USA) for accuracy of measurements of approximal bone loss. Methods and Materials Four dried human mandibles with complete dentition were selected. Radiographic images were made with a standardized technique. Mesial and distal bone levels on the mandibular premolar and molar teeth were measured on the two types of radiographs (Ekta-speed plus and Insight) by nine observers. The data obtained by the observers were compared with the primary investigators’ corresponding measurements, which served as “the ground truth” for this study. Results The results of the analysis of variance (ANOVA) demonstrated a significant difference for the Ektaspeed plus film (p = .001), but the difference was not clinically significant. The level of intra-rater reliability was high for the observers (0.969 to 0.990). Conclusion Performance of Ekta-speed plus and Insight films was found to be similar. Citation Masood F, Angelopoulos C, Glaros A. A Comparison Between Two Types of Radiographic Film for Accuracy of Measurements of Approximal Osseous Defects. J Contemp Dent Pract 2006 July;(7)3:022-029.


Sign in / Sign up

Export Citation Format

Share Document