scholarly journals Biomechanical Comparison of Augmentation of Engineered Tendon-Fibrocartilage-Bone Composite With Acellular Dermal Graft Using Double Rip-Stop Technique for Canine Rotator Cuff Repair

2020 ◽  
Vol 8 (9) ◽  
pp. 232596712093900
Author(s):  
Zhanwen Wang ◽  
Zeling Long ◽  
Peter C. Amadio ◽  
Anne Gingery ◽  
Steven L. Moran ◽  
...  

Background: The retear rate after rotator cuff repair remains unacceptably high. Various biological engineered scaffolds have been proposed to reduce the retear rate. We have developed a double rip-stop repair with medial row knot (DRSK) technique to enhance suture-tendon strength and a novel engineered tendon-fibrocartilage-bone composite (TFBC) for rotator cuff repair. Hypothesis: DRSK rotator cuff repair augmented with TFBC will have better biomechanical properties than that of DRSK repair with an acellular dermal graft (DG). Study Design: Controlled laboratory study. Methods: Fresh-frozen canine shoulders (n = 30) and knees (n = 10) were used. TFBCs were harvested from the patellar tendon–tibia complex and prepared for rotator cuff repair. The infraspinatus tendon was sharply detached from its bony attachment and randomly assigned to the (1) control group: DRSK repair alone, (2) TFBC group: DRSK repair with TFBC, and (3) DG group: DRSK repair with DG. All specimens were tested to failure, and videos were recorded. The footprint area, tendon thickness, load to create 3-mm gap formation, failure load, failure modes, and stiffness were recorded and compared. Data were recorded as mean ± SD. Results: The mean load to create a 3-mm gap in both the control group (206.8 ± 55.7 N) and TFBC group (208.9 ± 39.1 N) was significantly higher than that in the DG group (157.7 ± 52.3 N) ( P < .05 for all). The failure load of the control group (275.7 ± 75.0 N) and TFBC group (275.2 ± 52.5 N) was significantly higher compared with the DG group (201.5 ± 49.7 N) ( P < .05 for both comparisons). The stiffness of the control group (26.4 ± 4.7 N/mm) was significantly higher than of the TFBC group (20.4 ± 4.4 N/mm) and the DG group (21.1 ± 4.8 N/mm) ( P < .05 for both comparisons). Conclusion: TFBC augmentation showed superior biomechanical performance to DG augmentation in rotator cuff tears repaired using the DRSK technique, while there was no difference between the TFBC and control groups. Clinical Relevance: TFBC may help to reduce retear or gap formation after rotator cuff repair using the DRSK technique.

2020 ◽  
Vol 9 (6) ◽  
pp. 285-292
Author(s):  
Zhanwen Wang ◽  
Hong Li ◽  
Zeling Long ◽  
Subin Lin ◽  
Andrew R. Thoreson ◽  
...  

Aims Many biomechanical studies have shown that the weakest biomechanical point of a rotator cuff repair is the suture-tendon interface at the medial row. We developed a novel double rip-stop (DRS) technique to enhance the strength at the medial row for rotator cuff repair. The objective of this study was to evaluate the biomechanical properties of the DRS technique with the conventional suture-bridge (SB) technique and to evaluate the biomechanical performance of the DRS technique with medial row knots. Methods A total of 24 fresh-frozen porcine shoulders were used. The infraspinatus tendons were sharply dissected and randomly repaired by one of three techniques: SB repair (SB group), DRS repair (DRS group), and DRS with medial row knots repair (DRSK group). Specimens were tested to failure. In addition, 3 mm gap formation was measured and ultimate failure load, stiffness, and failure modes were recorded. Results The mean load to create a 3 mm gap formation in the DRSK and DRS groups was significantly higher than in the SB group. The DRSK group had the highest load to failure with a mean ultimate failure load of 395.0 N (SD 56.8) compared to the SB and DRS groups, which recorded 147.1 N (SD 34.3) and 285.9 N (SD 89.8), respectively (p < 0.001 for both). The DRS group showed a significantly higher mean failure load than the SB group (p = 0.006). Both the DRS and DRSK groups showed significantly higher mean stiffness than the SB group. Conclusion The biomechanical properties of the DRS technique were significantly improved compared to the SB technique. The DRS technique with medial row knots showed superior biomechanical performance than the DRS technique alone.


2012 ◽  
Vol 21 (5) ◽  
pp. 580-588 ◽  
Author(s):  
Hui Xu ◽  
Maryellen Sandor ◽  
Shijie Qi ◽  
Jared Lombardi ◽  
Jerome Connor ◽  
...  

Medicina ◽  
2021 ◽  
Vol 57 (5) ◽  
pp. 491
Author(s):  
Donghyun Yi ◽  
Hwanyong Lim ◽  
Jongeun Yim

Background and Objectives: The purpose of this study was to investigate the effects of microcurrent stimulation on pain, shoulder function, and grip strength in patients with rotator cuff repair. Materials and Methods: This randomized single-blind controlled trial was conducted on inpatients of the rehabilitation department, and included 28 patients who underwent rotator cuff repair. Participants were randomly assigned to the experimental group (n = 14), treated with microcurrent stimulation, and the control group (n = 14), treated with false microcurrent stimulation. The microcurrent stimulation administered to the experimental group underwent general physical therapy and microcurrent stimulation three times a week for 4 weeks. Results: Changes in pain, range of motion in shoulder, simple shoulder test, and grip strength were assessed before and after the intervention. Both groups showed a significant decrease in pain and shoulder function (t = 27.412, 22.079, 19.079, and 18.561; p < 0.001), and grip strength showed a significant increase (t = −8.251 and −9.946; p < 0.001). The experimental group that underwent microcurrent stimulation exhibited a significant effect on pain, shoulder function, and grip strength compared with the control group that underwent false microcurrent stimulation (t = −2.17, −2.22, and 2.213; p = 0.039, 0.035, and 0.036). Conclusions: This study confirmed that microcurrent stimulation is effective for the treatment of rotator cuff repair patients.


2015 ◽  
Vol 30 (9) ◽  
pp. 976-980 ◽  
Author(s):  
Xiaoxi Ji ◽  
Qingshan Chen ◽  
Andrew R. Thoreson ◽  
Jin Qu ◽  
Kai-Nan An ◽  
...  

2020 ◽  
Vol 48 (3) ◽  
pp. 706-714 ◽  
Author(s):  
Yucheng Sun ◽  
Jae-Man Kwak ◽  
Erica Kholinne ◽  
Youlang Zhou ◽  
Jun Tan ◽  
...  

Background: Microfracture of the greater tuberosity has been proved effective for enhancing tendon-to-bone healing after rotator cuff repair. However, no standard diameter for the microfracture has been established. Purpose/Hypothesis: This study aimed to assess treatment with large- and small-diameter microfractures to enhance healing during rotator cuff repair surgery in a rabbit model of chronic rotator cuff tear. It was hypothesized that a small-diameter microfracture had advantages in terms of tendon-to-bone integration, bone-tendon interface maturity, microfracture healing, and biomechanical properties compared with a large-diameter microfracture. Study Design: Controlled laboratory study. Methods: Bilateral supraspinatus tenotomy from the greater tuberosity was performed on 21 New Zealand White rabbits. Bilateral supraspinatus repair was performed 6 weeks later. Small-diameter (0.5 mm) microfracture and large-diameter microfracture (1 mm) were performed on the left side and right side, respectively, in 14 rabbits as a study group, and simple repair without microfracture was performed in 7 rabbits as a control group. At 12 weeks later, 7 of 14 rabbits in the study group were sacrificed for micro–computed tomography evaluation and biomechanical testing. Another 6 rabbits were sacrificed for histological evaluation. In the control group, 3 of the 7 rabbits were sacrificed for histological evaluation and the remaining rabbits were sacrificed for biomechanical testing. Results: Significantly better bone-to-tendon integration was observed in the small-diameter microfracture group. Better histological formation and maturity of the bone-tendon interface corresponding to better biomechanical results (maximum load to failure and stiffness) were obtained on the small-diameter microfracture side compared with the large-diameter side and the control group. The large-diameter microfracture showed worse radiographic and histological properties for healing of the microfracture holes on the greater tuberosity. Additionally, the large-diameter microfracture showed inferior biomechanical properties but similar histological results compared with the control group. Conclusion: Small-diameter microfracture showed advantages with enhanced rotator cuff healing for biomechanical, histological, and radiographic outcomes compared with large-diameter microfracture, and large-diameter microfracture may worsen the rotator cuff healing. Clinical Relevance: This animal study suggested that a smaller diameter microfracture may be a better choice to enhance healing in clinical rotator cuff repair surgery in humans.


2020 ◽  
Vol 15 (1) ◽  
Author(s):  
Sang-Uk Lee ◽  
Hyo-Jin Lee ◽  
Yang-Soo Kim

Abstract Background Arthroscopic rotator cuff repair is a painful procedure, and treatment of emetic events associated with drugs used in the current multimodal pain management remains challenging. This study aimed to evaluate the effectiveness of ramosetron or ondansetron to relieve postoperative nausea and vomiting (PONV) and pain after arthroscopic rotator cuff repair. Methods In total, 122 consecutive patients undergoing arthroscopic rotator cuff repair were randomly allocated into three groups: ramosetron group (n = 39), ondansetron group (n = 43), and control group (n = 40). Then, 0.3 mg of ramosetron or 8 mg of ondansetron was administered intravenously at the end of surgery according to group. All patients received general anesthesia and multimodal pain management protocol including preemptive analgesic medication, fentanyl-based intravenous patient-controlled analgesia, and postoperative analgesic medication. Incidence of emetic events, rescue antiemetic requirements (10 mg of metoclopramide, IV), complete response, pain level, and side effects were recorded in three periods: 0–6, 6–24, and 24–48 h postoperatively. The severity of nausea and pain was evaluated using a visual analog scale. Results The ramosetron group tended to have a lower incidence and severity of nausea during the 6- to 24-h postoperative period and fewer rescue antiemetic drug requirements during the 0- to 48-h period than the control group, showing statistical significance. Additionally, the frequency of complete response of the ramosetron and ondansetron groups was significantly higher than that of the control group. No difference was found among the groups in the pain level except during the 0- to 6-h period. The two groups have a higher complete response during the 6- to 24-h period than the control group. Conclusions Ramosetron use led to a lower incidence, mild severity of nausea, and reduced use of rescue antiemetic drug after arthroscopic rotator cuff repair during the 6- to 24-h postoperative period than the control. Level of evidence Level I, randomized controlled trials, treatment study


2017 ◽  
Vol 87 (6) ◽  
pp. 483-487 ◽  
Author(s):  
Lachlan Huntington ◽  
Martin Richardson ◽  
Tony Sobol ◽  
Jonathon Caldow ◽  
David C. Ackland

Sign in / Sign up

Export Citation Format

Share Document