scholarly journals Total Ankle Arthroplasty in Valgus Deformity

2020 ◽  
Vol 5 (4) ◽  
pp. 2473011420S0038
Author(s):  
Camilo Piga ◽  
Federico Giuseppe Usuelli ◽  
Camilla Maccario ◽  
Claudia A. Di Silvestri

Category: Ankle Arthritis Introduction/Purpose: Total ankle replacement use has increased among patients with end-stage ankle arthritis. Substantial coronal plane deformity is usual in that context. In addition, recent literature shows a trend towards the extension of the indication of total ankle arthroplasty in increasingly severe coronal deformities, showing good results when correct alignment is achieved. Nevertheless, the results of lateral transfibular total ankle replacement (LTTAR) in valgus has not been extensively studied. We aimed to evaluate if the outcomes of LTTAR in ankles with valgus deformity are similar with those with no major deformity. Methods: This retrospective cohort study included 228 LTTAR. Patients were classified into 2 groups according to the preoperative coronal plane tibiotalar angle (TTS): neutral (less than 10° of coronal deformity, 209 patients) and valgus (above 10° of valgus, 19 patients). Clinical evaluation was performed using American Orthopaedic Foot & Ankle Society Score (AOFAS), Visual analogue scale (VAS), short Form 12 Quality of Life (SF-12) regarding its physical (PCS) and mental (MCS) items. Radiographic evaluation considered anteroposterior and lateral ankle radiographs. Surgical times were recorded in all the cases. There were no differences between groups regarding mean age, mean body mass index and follow up. The minimum follow up was 24 months. Results: The average AOFAS, VAS and SF-12 scores improved significantly postoperatively (p-value<0.01), without differences between groups. At final radiographic follow up, the valgus alignment group did not show significant differences with the neutral alignment group regarding TTS, lateral distal tibial angle or anterior distal tibial angle (p-value>0.05). Surgical time was longer in the valgus group (152.84 +- 40.86 mins vs 129.51 +- 52.13), but the difference was not statistically significant. Conclusion: Lateral transfibular total ankle replacement in ankles with valgus deformity achieved and maintained correction of coronal alignment in a short term follow up, as obtained in neutral alignment ankles. Clinical outcomes improved significantly regardless preoperative valgus deformity. Additional surgical time may be needed in order to obtain a good deformity correction in a valgus ankle. This short term analysis shows that LTTAR in a valgus ankle seems to be a safe option in experienced surgeons hands.

2018 ◽  
Vol 3 (3) ◽  
pp. 2473011418S0005
Author(s):  
Francesco Granata ◽  
Camilla Maccario ◽  
Luigi Manzi ◽  
Eric Tan ◽  
Federico Giuseppe Usuelli

Category: Ankle Arthritis Introduction/Purpose: Ankle arthritis is a highly limiting pathology that causes pain and functional limitation with subsequent deterioration of quality of life. With recent advances in surgical instrumentation and techniques, prosthetic replacement of the ankle has proved to be a valid alternative to arthrodesis with comparable outcomes. The purpose of this study was to evaluate clinical and radiological findings in a transfibular total ankle replacement with two years follow-up. Methods: This prospective study included 59 patients who underwent transfibular total ankle arthroplasty from May 2013 to December 2015. The mean age was 51.6 ± 13.4 years. All patients were followed for at least 24 months postoperative with an average follow-up of 42.0 ± 23.5 months. Patients were assessed clinically and radiologically preoperatively and at 6, 12, and 24 months postoperatively. Results: At 24 months, patients demonstrated statistically significant improvement in the American Orthopaedic Foot and Ankle Society score from 33.6 to 88.1 (P<0.01), VAS scale from 79.3 to 14.0 (P<0.01) and SF-12 Physical and Mental Composite Scores from 29.9 and 44.6 to 74.4 and 95.3, respectively (P<0.01). Ankle dorsiflexion and plantarflexion improved from 5.5 and 8.8 degrees to 24.2 and 20.0 degrees, respectively (P<0.01). Radiographically, patients demonstrated neutral alignment of the ankle with a tibio-talar ratio of 34.9 ± 9.2 and hindfoot alignment view angle of 1.2 ± 7.0 degrees. No patient demonstrated any radiographic evidence of tibial or talar lucency at 24 months. Seven patients underwent reoperation for removal of symptomatic hardware; one patient developed a postoperative prosthetic infection requiring placement of an antibiotic spacer. Conclusion: This study demonstrates that transfibular total ankle replacement is a safe and effective option for the patients for ankle arthritis with improvements in patient-reported outcomes, range of motion, and radiological parameters. However, further studies are required to determine the mid- and long-term performance of these implants.


2018 ◽  
Vol 40 (1) ◽  
pp. 24-33 ◽  
Author(s):  
Federico G. Usuelli ◽  
Camilla Maccario ◽  
Francesco Granata ◽  
Cristian Indino ◽  
Venus Vakhshori ◽  
...  

Background: Ankle arthritis is a highly limiting pathology that causes pain and functional limitation with subsequent deterioration of quality of life. With recent advances in surgical instrumentation and techniques, prosthetic replacement of the ankle has proven to be a valid alternative to arthrodesis with comparable outcomes. The purpose of this study was to evaluate clinical and radiological findings in a transfibular total ankle replacement with follow-up of at least 2 years. Methods: This prospective study included 89 patients who underwent transfibular total ankle arthroplasty from May 2013 to February 2016. The mean age was 53.2 ± 13.5 years. All patients were followed for at least 24 months postoperatively with an average follow-up of 42.0 ± 23.5 months. Patients were assessed clinically and radiographically preoperatively and at 6, 12, and 24 months postoperatively. Results: At 24 months postoperatively, patients demonstrated statistically significant improvement in the American Orthopaedic Foot & Ankle Society (AOFAS) Ankle Hindfoot Score from 33.8 ± 14.3 to 88.5 ± 6.6 ( P < .001), visual analog scale (VAS) from 80.5 ± 17.0 to 14.1 ± 9.2 ( P < .001), and Short Form-12 Physical and Mental Composite Scores from 29.9 ± 6.7 and 43.3 ± 8.6 to 47.0 ± 7.6 and 53.3 ± 8.1, respectively ( P < .001). In addition, ankle dorsiflexion and plantarflexion improved from 6.2 ± 5.5 and 9.6 ± 5.8 degrees to 24.2 ± 7.9 and 18.1 ± 7.6 degrees, respectively ( P < .001). Radiographically, patients demonstrated maintained neutral alignment of the ankle at 24 months. No patient demonstrated any radiographic evidence of tibial or talar lucency at final follow-up. Seven patients underwent reoperation for removal of symptomatic hardware (6 fibular plates, 1 syndesmotic screw); 2 patients experienced delayed wound healing. The first one was treated with plate removal and flap coverage. The second one required fibular plate removal. One patient developed a postoperative prosthetic infection requiring operative debridement, removal of implants, and placement of an antibiotic spacer. Conclusion: This study found that transfibular total ankle replacement was a safe and effective option for patients with ankle arthritis resulting in improvements in patient-reported outcomes, range of motion, and radiographic parameters. However, further studies are required to determine the mid- and long-term performance of these implants. Level of Evidence: Level IV, case series.


2018 ◽  
Vol 3 (3) ◽  
pp. 2473011418S0006
Author(s):  
Mansur Halai ◽  
Matthew Mann ◽  
Ryan Khan ◽  
Ellie Pinsker ◽  
Timothy Daniels

Category: Ankle Arthritis Introduction/Purpose: Preoperative talar valgus deformity increases the technical difficulty of total ankle replacement (TAR) and is associated with an increased failure rate. Deformity of ≥15° has been reported to be a contraindication to arthroplasty. The goal of the present study was to determine whether the clinical outcomes of TAR for treatment of end-stage ankle arthritis were comparable for patients with preoperative talar valgus deformity of ≥15° as compared to those with <15°. Methods: Fifty ankles with preoperative coronal-plane tibiotalar valgus deformity of ≥15° (“valgus” group) and 50 ankles with valgus deformity of <15° (“control” group) underwent TAR. The cohorts were similar with respect to demographics and components used. All TARs were performed by a single surgeon. The mean duration of clinical follow-up was 5.5 years (minimum two years). Preoperative and postoperative radiographic measurements of coronal-plane deformity, Ankle Osteoarthritis Scale (AOS) scores and Short Form (SF)-36 scores were prospectively recorded. All ancillary (intraoperative) and secondary procedures, complications and measurements were collected. Results: The AOS pain and disability subscale scores decreased significantly in both groups. The improvement in AOS and SF-36 scores did not differ significantly between the groups at the time of the final follow-up. The valgus group underwent more ancillary procedures during the index surgery (80% vs 26%). Tibio-talar deformity improved significantly toward a normal weight-bearing axis in the valgus group. Secondary postoperative procedures were more common in the valgus group (36%) than the controls (20%). Overall, re-operation was not associated with poorer patient outcome scores. Metal component revision surgery occurred in seven patients (three valgus and four controls). These revisions included two deep infections (2%), one in each group, which were converted to hindfoot fusions. Therefore, 94% of the valgus group retained their original components at final follow-up. Conclusion: Satisfactory midterm results were achieved in patients with valgus mal-alignment of ≥15°. The valgus cohort required more procedures during and after their TAR, as well as receiving more novel techniques to balance their TAR. Whilst longer term studies are needed, valgus coronal-plane alignment of ≥15° should not be considered an absolute contraindication to TAR if the associated deformities are addressed.


2021 ◽  
pp. 107110072098528
Author(s):  
Camilo Piga ◽  
Camilla Maccario ◽  
Riccardo D’Ambrosi ◽  
Fausto Romano ◽  
Federico Giuseppe Usuelli

Background: A substantial coronal plane deformity is common in the context of end-stage ankle osteoarthritis. Recent literature shows a trend toward extending the indication of total ankle arthroplasty in increasingly severe coronal deformities, showing promising results when correct alignment is achieved. Nevertheless, the results of lateral transfibular total ankle replacement (LTTAR) in valgus has not been extensively studied. We aimed to evaluate if the outcomes of LTTAR in ankles with valgus deformity were similar to those with no major deformity at short-term follow-up. Methods: This retrospective cohort study included 228 LTTARs. Patients were classified into 2 groups according to the preoperative coronal plane tibiotalar angle (TTS): neutral (less than 10 degrees of coronal deformity, 209 patients) and valgus (above 10 degrees of valgus, 19 patients). Clinical evaluation was performed using the American Orthopaedic Foot & Ankle Society (AOFAS) score, visual analog scale (VAS), 12-Item Short Form Health Survey 12 (SF-12) regarding its Physical and Mental Component Summary items. The radiographic evaluation considered anteroposterior and lateral ankle radiographs. Complications were also registered and classified as major or minor. The minimum follow-up was 2 years. Results: The average AOFAS, VAS, and SF-12 scores improved significantly postoperatively ( P < .001), without differences between groups. At final radiographic follow-up, the valgus alignment group did not show significant differences with the neutral alignment group regarding TTS, lateral distal tibial angle, or anterior distal tibial angle ( P > .05). Conclusion: LTTAR in cases with valgus deformity achieved and maintained correction at short-term follow-up, as obtained in neutral alignment ankles. Clinical outcomes improved significantly regardless of preoperative valgus deformity. Level of Evidence: Prognostic Level III, retrospective cohort study.


2021 ◽  
pp. 193864002098092
Author(s):  
Devon W. Consul ◽  
Anson Chu ◽  
Travis M. Langan ◽  
Christopher F. Hyer ◽  
Gregory Berlet

Total ankle replacement has become a viable alternative to ankle arthrodesis in the surgical management of advanced ankle arthritis. Total ankle replacement has generally been reserved for patients who are older and for those who will have a lower demand on the replacement. The purpose of the current study is to review patient outcomes, complications, and implant survival in patients younger than 55 years who underwent total ankle replacement at a single institution. A single-center chart and radiographic review was performed of consecutive patients who underwent total ankle replacement for treatment of end-stage ankle arthritis. All surgeries were performed by 1 of 5 fellowship-trained foot and ankle surgeons at a single institution. A total of 51 patients met inclusion criteria with a mean follow-up of 31.2 months (SD = 16.2). Implant survival was 94%, There were 7 major complications (13%) requiring an unplanned return to the operating room and 8 minor complications (15%) that resolved with conservative care. The results of this study show that total ankle replacement is a viable treatment option for patients younger than 55 years. Levels of Evidence: A retrospective case series


2019 ◽  
Vol 4 (4) ◽  
pp. 2473011419S0028
Author(s):  
Karim Mahmoud ◽  
Sreenivasulu Metikala ◽  
Kathryn O’Connor ◽  
Daniel Farber

Category: Ankle Arthritis Introduction/Purpose: Total ankle replacement has become a popular treatment option for end stage ankle arthritis. Most of the reports of adverse events following total ankle replacement have been from high volume institutions and are subject to either observational or selection bias as well as potential under-reporting as they do not include the experience of community and lower volume centers and surgeons. The FDA’s Medical and User Facility Device Experience (MAUDE) Database provides a more complete scope of adverse events due to the mandatory reporting requirements by the FDA of implant manufactures. We reviewed the database to identify the common modes of failure and complications of total ankle implants Methods: We retrospectively reviewed reports of the MAUDE database from November 2011 to September 2018 regarding all total ankle implants. Each device in the MAUDE database is classified with a 3-letter code, we identified the 2 codes assigned to total ankle arthroplasty devices, and manually searched the FDA’s published Device Classification list for adverse events. All events were reviewed and classified. Data related to patient age or sex, surgeon, medical center location are not available in the database Results: We identified 1000 adverse reports in the period between November 2011 and September 2018. After exclusion of duplicate reports for single events or reports irrelevant to total ankle arthroplasty, a total of 697 adverse event reports were noted. The most common mode of failure was aseptic loosening (21%), followed by infection (16%), alignment and mechanical issues (instability, malalignment, malposition, stiffness, impingement) (15%), implantation issues (pin, screw or drill breakage, alignment guide problems) (9%), polyethylene related problems (wear, displaced or fractured implants) (7%), bony and soft tissue overgrowth (6%), and peri-prosthetic fractures (5%). Conclusion: Our analysis reveals that the most reported mode of failure was aseptic loosening followed by infection. However, it is notable that there are a significant number of issues with implant alignment and mechanics, complications during implantation and polyethylene component failure that are under-reported in the literature. Knowledge of these adverse events may help surgeons avoid similar complications as well as lead to improvement in component implantation and design


2021 ◽  
Vol 10 (11) ◽  
pp. 2258
Author(s):  
Massimiliano Mosca ◽  
Silvio Caravelli ◽  
Emanuele Vocale ◽  
Simone Massimi ◽  
Davide Censoni ◽  
...  

Recently, the progress in techniques and in projecting new prosthetic designs has allowed increasing indications for total ankle replacement (TAR) as treatment for ankle osteoarthritis. This retrospective work comprehended 39 subjects aged between 47 and 79 years old. The patients, observed for at least 12 months (mean follow up of 18.2 ± 4.1 months), have been evaluated according to clinical and radiological parameters, both pre- and post-operatively. The AOFAS and VAS score significantly improved, respectively, from 46.2 ± 4.8 to 93.9 ± 4.1 and from 7.1 ± 1.1 to 0.7 ± 0.5 (p value < 0.05). At the final evaluation, the mean plantarflexion passed from 12.2° ± 2.3° to 18.1° ± 2.4° (p value < 0.05) and dorsiflexion from a pre-operative mean value of 8.7° ± 4.1° to 21.7° ± 5.4° post-operatively (p value < 0.05). This study found that this new total ankle replacement design is a safe and effective procedure for patients effected by end-stage ankle osteoarthritis. Improvements have been demonstrated in terms of range of motion, radiographic parameters and patient-reported outcomes. However, further studies are needed to assess the long-term performance of these prostheses.


2018 ◽  
Vol 3 (3) ◽  
pp. 2473011418S0009
Author(s):  
James Nunley ◽  
Samuel Adams ◽  
James DeOrio ◽  
Mark Easley

Category: Ankle Arthritis Introduction/Purpose: Outcomes of total ankle replacement for the treatment of end-stage ankle arthritis continue to improve. Debate continues whether a mobile-bearing total ankle replacement (MB-TAR) or a fixed-bearing total ankle replacement (FB-TAR) is superior, with successful outcomes reported longterm for MB-TAR and at intermediate-to-longterm follow-up for newer generation FB-TAR. Although comparisons between the two total ankle designs have been reported, to our knowledge, no investigation has compared the two designs with a high level of evidence. This prospective, randomized controlled trial conducted at a single institution compares patient satisfaction, functional outcomes and radiographic results of the mobile-bearing STAR and the fixed-bearing Salto-Talaris in the treatment of end-stage ankle arthritis. Methods: This investigation was approved by our institution’s IRB committee. Between November 2011 and November 2014, adult patients with end-stage ankle osteoarthritis failing nonoperative treatment were introduced to the study. With informed consent, 100 patients (31 male and 69 female, average age 65, range 35 to 85) were enrolled; demographic comparison between the two cohorts was similar. Exclusion criteria included inflammatory arthropathy, neuropathy, weight exceeding 250 pounds, radiographic coronal plane deformity greater than 15 degrees or extensive talar dome wear pattern (“flat top talus”). Prospective patient-reported outcomes, physical exam and standardized weightbearing ankle radiographs were obtained preoperatively, at 6 and 12 months postoperatively, and then at yearly intervals. Data collection included visual analog pain score (VAS), short form 36 (SF-36), foot and ankle disability index (FADI), short musculoskeletal functional assessment (SMFA) and AOFAS ankle-hindfoot score. Surgeries were performed by non-design team orthopaedic foot and ankle specialists with total ankle replacement expertise. Statistically analysis was performed by a qualified statistician. Results: At average follow-up of 4.5 years (range 2-6 years) complete clinical data and radiographs were available for 84 patients; 7 had incomplete data, one had died, 4 were withdrawn after enrolling but prior to surgery and 4 were lost to follow-up. In all outcome measures, the entire cohort demonstrated statistically significant improvements from preoperative evaluation to most recent follow-up. There was no statistically significant difference in improvement in clinical outcomes between the two groups. Radiographically, tibial lucency/cyst formation was 26.8% and 20.9% for MB-TAR and FB-TAR, respectively. Tibial settling/subsidence occurred in 7.3% of MB-TAR. Talar lucency/cyst formation occurred in 24.3% and 2.0% of MB-TAR and FB-TAR, respectively. Talar subsidence was observed in 21.9% and 2.0% of MB-TAR and FB-TAR, respectively. Re-operations were performed in 8 MB-TAR and 3 FB-TAR, with the majority of procedures being to relieve impingement or treat cysts and not to revise or remove metal implants. Conclusion: For the first time, with a high level of evidence, our study confirms that patient reported and clinical outcomes are favorable for both designs and that there is no significant difference in clinical improvement between the two implants. The incidence of lucency/cyst formation was similar for MB-TAR and FB-TAR for the tibial component, but the MB-TAR had greater talar lucency/cyst formation and tibial and talar subsidence. As has been suggested in previous studies, clinical outcomes do not correlate with radiographic findings. Re-operations were more common for MB-TAR and in the majority of cases were to relieve impingement or treat cysts rather than revise or remove metal implants.


2020 ◽  
Vol 5 (4) ◽  
pp. 2473011420S0042
Author(s):  
Hatem Salem-Saqer ◽  
Martin Raglan ◽  
Sunil Dhar

Category: Ankle; Ankle Arthritis Introduction/Purpose: Total ankle arthroplasty (TAA) is increasingly used for treatment of end stage arthritis of the ankle; improvements continue to evolve in implant design and instrumentation. We present our experience of the Infinity Total Ankle Arthroplasty (Wright Medical), a fixed bearing 4th generation implant with improved instrumentation Methods: This is a retrospective review of prospectively collected data. From October 2016 to July 2019, we identified 92 (52M/40F) who had the infinity Total Ankle Replacement. This review is of 70 patients with a minimum of 1 year follow up (33M,37F). The mean age was 67.5 years (33-87); 32 right side and 38 left no bilaterals. The indication for surgery was end stage Osteoarthritis in 52, post traumatic arthritis 12, inflammatory arthritis 4, conversion of fusion to TAR 2. The preoperative deformity was graded according to the COFAS classification. All patients had follow up at 6 weeks, 3,6 and 12 months and then annually, with MOXFQ questionnaire and weight bearing radiographs. Results: TAA was performed with the use of fluoroscopy. 77% (54/70) had concomitant procedures as listed in Table.5% (4/70) had complications consisting of, 1 DVT, 1 intra operative medial malleolus fracture, 1 EHL tendon laceration and 1 wound break down. There were no deep or superficial infections. Improvement in clinical outcome and PROMS data was noted on follow up. The MOXFQ for Pain improved from 72 pre-op to 25 at 1year (p<0.001). The outcome for Walking improved from 83 pre-op to 30 at one year (p<0.001). Radiological alignment was maintained asymptomatic posterior heterotopic ossification was noted in 23(16%) patients, lucent lines under the tibial implant were noted in 4 ankles and 1 fibula erosion. 2 TAA (3%) needed to be revised due to malpositioning. Conclusion: Our results show significant improvement in patient outcomes, a short recovery time and marked improvement in mobility post operatively with a very low complication rate, we had no deep infection to date. Two implants were revised which we attribute to the learning curve at the start of practice. This implant is fluoroscopically navigated allowing precise implantation with dedicated instrumentation and we feel this attributed to the low complication rate and good results in our short-term study [Table: see text]


2017 ◽  
Vol 2 (3) ◽  
pp. 2473011417S0002
Author(s):  
Camilla Maccario ◽  
Cristian Indino ◽  
Luigi Manzi ◽  
Federico Giuseppe Usuelli ◽  
Claudia Di Silvestri

Category: Ankle, Ankle Arthritis Introduction/Purpose: Primary ankle osteoarthritis is very uncomon, in fact 70-78% of the case ankle arthritis has a post- traumatic cause. Ankle arthrodesis (AA), has been considered a reliable procedure for resolution of ankle osteoarthritis. Recent modifications in Total ankle replacement (TAR) designs have challenged the perception that AA is the treatment of choice for end-stage ankle arthritis. Trabecular Metal Total Ankle system is a fixed-bearing prosthesis. The new design is flanked by use of new materials. The tibial articular surface is constructed of highly crosslinked UHMWPE and Trabecular Metal lining the talar and the tibial base component. The purpose of this retrospective study was to show the preliminary result in 31 patients underwent to ankle replacement using Zimmer Trabecular Metal Total Ankle system. Methods: We retrospectively assessed prospectively collected data on the initial cohort of 31 patients undergoing TAR with this implant. Clinical evaluation was determined pre and postoperatively for a minimum of 24 months after surgery. Pain was rated using the visual analogue scale (VAS). Functional results were assessed as well as ankle range of motion (ROM). Clinical outcomes used where the Short Form SF-12 Quality of Life score, the American Foot and Ankle Society (AOFAS). The imaging follow-up included ankle radiographs done at 6, 12 and 24 months. Radiological parameters were angles??(normal values 90 +- 2),?? (normal value 85 +- 2),??? normal values 20 +- 2) and TTratio? normal values: 27% to 42%). Results: The study included 31 ankles of TM Ankle Replacement in 31 consecutive patients over a period of 2 years (2013–2015). Out of 31 patients, 13 were females and 18 were males (average age 49.4 years, range, 30–75 years). All procedures were performed by a single surgeon. The ROM plantarflexion and dorsiflexion improved significantly (p <0.001) at the last follow up. The mean VAS pain score decreased significantly from 7.42 points (range 4 – 10 points) preoperatively to 1.42 points (range, 0 - 3 points) at the time of the latest follow-up (p <0.001). AOFAS and SF-12 scores both improved from postoperatively to the last follow up. (Table 1). We noted stable implants based on our radiographic parameters, with no corrections loosening. (Table 2) Conclusion: Our study evaluated the new fixed bearing Zimmer TM total ankle replacement approved by the US FDA in 2012 and is the first studies to evaluate the clinical and radiographic outcomes of this prosthesis. Of 31 ankles treated with a new transfibular arthroplasty system, only two asymptomatic fibular delayed union were registered. No implant failure was noted at 24 months postoperatively. Four ankles underwent secondary surgery for symptomatic fibular hardware with good outcome. The findings suggest that this total ankle system is safe and effective at short-term follow-up.


Sign in / Sign up

Export Citation Format

Share Document