scholarly journals Investigation on Reduction of Pressure Fluctuation for a Double-Suction Centrifugal Pump

Author(s):  
Qianqian Li ◽  
Shiyang Li ◽  
Peng Wu ◽  
Bin Huang ◽  
Dazhuan Wu

AbstractDouble-suction centrifugal pumps have been applied extensively in many areas, and the significance of pressure fluctuations inside these pumps with large power is becoming increasingly important. In this study, a double-suction centrifugal pump with a high-demand for vibration and noise was redesigned by increasing the flow uniformity at the impeller discharge, implemented by combinations of more than two parameters. First, increasing the number of the impeller blades was intended to enhance the bounding effect that the blades imposed on the fluid. Subsequently, increasing the radial gap between the impeller and volute was applied to reduce the rotor-stator interaction. Finally, the staggered arrangement was optimized to weaken the efficacy of the interference superposition. Based on numerical simulation, the steady and unsteady characteristics of the pump models were calculated. From the fluctuation analysis in the frequency domain, the dimensionless pressure fluctuation amplitude at the blade passing frequency and its harmonics, located on the monitoring points in the redesigned pumps (both with larger radial gap), are reduced a lot. Further, in the volute of the model with new impellers staggered at 12°, the average value for the dimensionless pressure fluctuation amplitude decreases to 6% of that in prototype pump. The dimensionless root-mean-square pressure contour on the mid-span of the impeller tends to be more uniform in the redesigned models (both with larger radial gap); similarly, the pressure contour on the mid-section of the volute presents good uniformity in these models, which in turn demonstrating a reduction in the pressure fluctuation intensity. The results reveal the mechanism of pressure fluctuation reduction in a double-suction centrifugal pump, and the results of this study could provide a reference for pressure fluctuation reduction and vibration performance reinforcement of double-suction centrifugal pumps and other pumps.

2019 ◽  
Vol 36 (4) ◽  
pp. 401-410 ◽  
Author(s):  
Xiao-Qi Jia ◽  
Bao-Ling Cui ◽  
Zu-Chao Zhu ◽  
Yu-Liang Zhang

Abstract Affected by rotor–stator interaction and unstable inner flow, asymmetric pressure distributions and pressure fluctuations cannot be avoided in centrifugal pumps. To study the pressure distributions on volute and front casing walls, dynamic pressure tests are carried out on a centrifugal pump. Frequency spectrum analysis of pressure fluctuation is presented based on Fast Fourier transform and steady pressure distribution is obtained based on time-average method. The results show that amplitudes of pressure fluctuation and blade-passing frequency are sensitive to the flow rate. At low flow rates, high-pressure region and large pressure gradients near the volute tongue are observed, and the main factors contributing to the pressure fluctuation are fluctuations in blade-passing frequency and high-frequency fluctuations. By contrast, at high flow rates, fluctuations of rotating-frequency and low frequencies are the main contributors to pressure fluctuation. Moreover, at low flow rates, pressure near volute tongue increases rapidly at first and thereafter increases slowly, whereas at high flow rates, pressure decreases sharply. Asymmetries are observed in the pressure distributions on both volute and front casing walls. With increasing of flow rate, both asymmetries in the pressure distributions and magnitude of the pressure decrease.


Author(s):  
Qian-qian Li ◽  
Da-zhuan Wu

Due to the distinctive characteristic of massive flow rates, double-suction centrifugal pump has been extensively applied in lots of perspectives, such as drainage, irrigation, transportation projects and other hydraulic engineering realms. Nevertheless, the significance of the pressure fluctuation inside the double-suction centrifugal pump, which is getting more and more prominent under the soaring demands for low noise and comfortable living environment, could not be underestimated. Consequently, how to reduce the pressure fluctuation as far as possible and enhance the running stability of the pump is always the research hotspot. In this study, the double-suction centrifugal impeller with abominable vibration performance is redesigned to improve the internal flow and reduce the flow-induced noise. What’s addition, the two redesigned impellers wearing splitter blades were compared in staggered arrangement with different angles for the purpose of ulteriorly decreasing the pressure fluctuation. On the basis of Realizable k-ε model and SIMPLEC algorithm, the unsteady Reynolds-averaged Navier-Stokes equations (URANS) were resolved by means of CFD simulation and the flow performance and the vibration performance were validated with the experiments. The results illustrate that the redesigned impeller with multi-blade could raise the hydraulic performance and reduce the pressure fluctuation inside the pump. When the impeller of each side was laid with the staggered angle of 12 degrees, the pressure distribution tended to be more uniform and the pressure fluctuation was well ameliorated. Through the pressure fluctuation analysis in time domain and frequency domain, the pressure change inside the pumps could be evaluated quantitatively and accurately, hence different pumps could be contrasted in detail. The consequences of this paper could provide reference for pressure fluctuation reduction and vibration performance reinforcement of double-suction centrifugal pumps as well as other vane pumps.


Author(s):  
Zhifeng Yao ◽  
Min Yang ◽  
Ruofu Xiao ◽  
Fujun Wang

The unsteady flow field and pressure fluctuations in double-suction centrifugal pumps are greatly affected by the wall roughness of internal surfaces. To determine the wall roughness effect, numerical and experimental investigations were carried out. Three impeller schemes for different wall roughness were solved using detached eddy simulation, and the performance and pressure fluctuations resolved by detached eddy simulation were compared with the experimental data. The results show that the effects of wall roughness on the static performance of a pump are remarkable. The head and efficiency of the tested double-suction centrifugal pump are raised by 2.53% and 6.60% respectively as the wall roughness is reduced by means of sand blasting and coating treatments. The detached eddy simulation method has been proven to be accurate for the prediction of the head and efficiency of the double-suction centrifugal pump with roughness effects. The influence of the roughness on pressure fluctuation is greatly dependent on the location relative to the volute tongue region. For locations close to the volute tongue, the peak-to-peak value of the pressure fluctuations of a wall roughness of Ra = 0.10 mm may be 23.27% larger than the case where Ra = 0.02 mm at design flow rate.


2016 ◽  
Vol 2016 ◽  
pp. 1-11 ◽  
Author(s):  
Lei Cao ◽  
Zhengwei Wang ◽  
Yexiang Xiao ◽  
Yongyao Luo

Clearance flows in the sidewall gaps of centrifugal pumps are unsteady as well as main flows in the volute casing and impeller, which may cause vibration and noise, and the corresponding pressure fluctuations are related to the axial clearance size. In this paper, unsteady numerical simulations were conducted to predict the unsteady flows within the entire flow passage of a centrifugal pump operating in the design condition. Pressure fluctuation characteristics in the volute casing, impeller, and sidewall gaps were investigated with three axial clearance sizes. Results show that an axial clearance variation affects the pressure fluctuation characteristics in each flow domain by different degree. The greatest pressure fluctuation occurs at the blade pressure surface and is almost not influenced by the axial clearance variation which has a certainly effect on the pressure fluctuation characteristics around the tongue. The maximum pressure fluctuation amplitude in the sidewall gaps is larger than that in the volute casing, and different spectrum characteristics show up in the three models due to the interaction between the clearance flow and the main flow as well as the rotor-stator interaction. Therefore, clearance flow should be taken into consideration in the hydraulic design of centrifugal pumps.


Processes ◽  
2019 ◽  
Vol 7 (6) ◽  
pp. 354 ◽  
Author(s):  
Ling Bai ◽  
Ling Zhou ◽  
Chen Han ◽  
Yong Zhu ◽  
Weidong Shi

A pump is one of the most important machines in the processes and flow systems. The operation of multistage centrifugal pumps could generate pressure fluctuations and instabilities that may be detrimental to the performance and integrity of the pump. In this paper, a numerical study of the influence of pressure fluctuations and unsteady flow patterns was undertaken in the pump flow channel of three configurations with different diffuser vane numbers. It was found that the amplitude of pressure fluctuation in the diffuser was increased gradually with the increase in number of diffuser vanes. The lower number of diffuser vanes was beneficial to obtain a weaker pressure fluctuation intensity. With the static pressure gradually increasing, the effects of impeller blade passing frequency attenuated gradually, and the effect of diffuser vanes was increased gradually.


Author(s):  
Wenjie Wang ◽  
Shouqi Yuan ◽  
Ji Pei ◽  
Giorgio Pavesi ◽  
Yandong Gu

To investigate the influence of relative positions between a radial diffuser and an annular volute on the unsteady pressure at the centrifugal pump outlet, experiment tests were carried out with five positions between the diffuser and volute in an open test rig. Statistical and frequency spectrum analyses were carried out to obtain the pressure fluctuation amplitude range and the frequency domain respectively. The results showed that the relative position has greater influence on the pressure at large flow rate than at part load condition. The dominant frequency and the Power Spectrum Density (PSD) values are affected by diffuser azimuthal position and the harmonic frequencies are determined by number of blades and vanes. The investigation can give a reference to optimize the relative angle between diffuser and volute to reduce the pressure fluctuations.


Author(s):  
Stefan Berten ◽  
Philippe Dupont ◽  
Laurent Fabre ◽  
Maher Kayal ◽  
Francois Avellan ◽  
...  

In centrifugal pumps, the interaction between the rotating impeller and the stationary diffuser generates specific pressure fluctuation patterns. When the pump is operated at off design conditions, these pressure fluctuations increase. The resulting rise of mechanical vibration levels may negatively affect the operational performance and the life span of mechanical components. This paper presents detailed pressure fluctuation measurements performed in a high speed centrifugal pump stage at full scale at various operating conditions. The impeller and stationary part (diffuser, exit chamber) of the pump stage have been equipped with piezoresistive miniature pressure sensors. The measured data in the impeller have been acquired using a newly developed onboard data acquisition system, designed for rotational speeds up to 6000 rpm. The measurements have been performed synchronously in the rotating and stationary domains. The analysis of pressure fluctuations at the impeller blade trailing edge, which had significantly larger amplitudes as the pressure fluctuations in the stationary domain, allowed the detection and exploration of stalled channels in the vaned diffuser. This stall may be stationary or rotating with different rotational speeds and number of stalled channels, depending on the relative flow rate and the rotational speed of the pump. The stall yields pressure fluctuations at frequencies which are multiples of the rotational speed of the impeller and generates additional sources of mechanical excitation.


Processes ◽  
2021 ◽  
Vol 9 (8) ◽  
pp. 1408 ◽  
Author(s):  
Bin Huang ◽  
Guitao Zeng ◽  
Bo Qian ◽  
Peng Wu ◽  
Peili Shi ◽  
...  

The pressure fluctuation inside centrifugal pumps is one of the main causes of hydro-induced vibration, especially at the blade-passing frequency and its harmonics. This paper investigates the feature of blade-passing frequency excitation in a low-specific-speed centrifugal pump in the perspective of local Euler head distribution based on CFD analysis. Meanwhile, the relation between local Euler head distribution and pressure fluctuation amplitude is observed and used to explain the mechanism of intensive pressure fluctuation. The impeller blade with ordinary trailing edge profile, which is the prototype impeller in this study, usually induces wake shedding near the impeller outlet, making the energy distribution less uniform. Because of this, the method of reducing pressure fluctuation by means of improving Euler head distribution uniformity by modifying the impeller blade trailing edge profile is proposed. The impeller blade trailing edges are trimmed in different scales, which are marked as model A, B, and C. As a result of trailing edge trimming, the impeller outlet angles at the pressure side of the prototype of model A, B, and C are 21, 18, 15, and 12 degrees, respectively. The differences in Euler head distribution and pressure fluctuation between the model impellers at nominal flow rate are investigated and analyzed. Experimental verification is also conducted to validate the CFD results. The results show that the blade trailing edge profiling on the pressure side can help reduce pressure fluctuation. The uniformity of Euler head circumferential distribution, which is directly related to the intensity of pressure fluctuation, is improved because the impeller blade outlet angle on the pressure side decreases and thus the velocity components are adjusted when the blade trailing edge profile is modified. The results of the investigation demonstrate that blade trailing edge profiling can be used in the vibration reduction of low specific impellers and in the engineering design of centrifugal pumps.


Author(s):  
Eduardo Blanco ◽  
Rau´l Barrio ◽  
Jorge Parrondo ◽  
Jose´ Gonza´lez ◽  
Joaqui´n Ferna´ndez

A study is presented on the numerical computation of the unsteady flow through a single suction and single volute centrifugal pump equipped with three impellers of different outlet diameter. Computations were performed by means of the Fluent code, solving the 3D URANS equations. The study was focused on the effect of varying the impeller-volute radial gap on the flow perturbations associated to the fluid-dynamic blade-tongue interaction. In order to contrast the numerical predictions, an experimental series of tests was conducted for the pump with the bigger impeller, to obtain pressure fluctuation data along the volute front wall. Finally, the results from the numerical simulations were used to compute the radial forces at the blade passing frequency, as a function of flow-rate and blade-tongue radial gap.


Sign in / Sign up

Export Citation Format

Share Document