scholarly journals Numerical Study of Pressure Fluctuation and Unsteady Flow in a Centrifugal Pump

Processes ◽  
2019 ◽  
Vol 7 (6) ◽  
pp. 354 ◽  
Author(s):  
Ling Bai ◽  
Ling Zhou ◽  
Chen Han ◽  
Yong Zhu ◽  
Weidong Shi

A pump is one of the most important machines in the processes and flow systems. The operation of multistage centrifugal pumps could generate pressure fluctuations and instabilities that may be detrimental to the performance and integrity of the pump. In this paper, a numerical study of the influence of pressure fluctuations and unsteady flow patterns was undertaken in the pump flow channel of three configurations with different diffuser vane numbers. It was found that the amplitude of pressure fluctuation in the diffuser was increased gradually with the increase in number of diffuser vanes. The lower number of diffuser vanes was beneficial to obtain a weaker pressure fluctuation intensity. With the static pressure gradually increasing, the effects of impeller blade passing frequency attenuated gradually, and the effect of diffuser vanes was increased gradually.

Author(s):  
Stefan Berten ◽  
Philippe Dupont ◽  
Laurent Fabre ◽  
Maher Kayal ◽  
Francois Avellan ◽  
...  

In centrifugal pumps, the interaction between the rotating impeller and the stationary diffuser generates specific pressure fluctuation patterns. When the pump is operated at off design conditions, these pressure fluctuations increase. The resulting rise of mechanical vibration levels may negatively affect the operational performance and the life span of mechanical components. This paper presents detailed pressure fluctuation measurements performed in a high speed centrifugal pump stage at full scale at various operating conditions. The impeller and stationary part (diffuser, exit chamber) of the pump stage have been equipped with piezoresistive miniature pressure sensors. The measured data in the impeller have been acquired using a newly developed onboard data acquisition system, designed for rotational speeds up to 6000 rpm. The measurements have been performed synchronously in the rotating and stationary domains. The analysis of pressure fluctuations at the impeller blade trailing edge, which had significantly larger amplitudes as the pressure fluctuations in the stationary domain, allowed the detection and exploration of stalled channels in the vaned diffuser. This stall may be stationary or rotating with different rotational speeds and number of stalled channels, depending on the relative flow rate and the rotational speed of the pump. The stall yields pressure fluctuations at frequencies which are multiples of the rotational speed of the impeller and generates additional sources of mechanical excitation.


2019 ◽  
Vol 36 (4) ◽  
pp. 401-410 ◽  
Author(s):  
Xiao-Qi Jia ◽  
Bao-Ling Cui ◽  
Zu-Chao Zhu ◽  
Yu-Liang Zhang

Abstract Affected by rotor–stator interaction and unstable inner flow, asymmetric pressure distributions and pressure fluctuations cannot be avoided in centrifugal pumps. To study the pressure distributions on volute and front casing walls, dynamic pressure tests are carried out on a centrifugal pump. Frequency spectrum analysis of pressure fluctuation is presented based on Fast Fourier transform and steady pressure distribution is obtained based on time-average method. The results show that amplitudes of pressure fluctuation and blade-passing frequency are sensitive to the flow rate. At low flow rates, high-pressure region and large pressure gradients near the volute tongue are observed, and the main factors contributing to the pressure fluctuation are fluctuations in blade-passing frequency and high-frequency fluctuations. By contrast, at high flow rates, fluctuations of rotating-frequency and low frequencies are the main contributors to pressure fluctuation. Moreover, at low flow rates, pressure near volute tongue increases rapidly at first and thereafter increases slowly, whereas at high flow rates, pressure decreases sharply. Asymmetries are observed in the pressure distributions on both volute and front casing walls. With increasing of flow rate, both asymmetries in the pressure distributions and magnitude of the pressure decrease.


Processes ◽  
2021 ◽  
Vol 9 (8) ◽  
pp. 1408 ◽  
Author(s):  
Bin Huang ◽  
Guitao Zeng ◽  
Bo Qian ◽  
Peng Wu ◽  
Peili Shi ◽  
...  

The pressure fluctuation inside centrifugal pumps is one of the main causes of hydro-induced vibration, especially at the blade-passing frequency and its harmonics. This paper investigates the feature of blade-passing frequency excitation in a low-specific-speed centrifugal pump in the perspective of local Euler head distribution based on CFD analysis. Meanwhile, the relation between local Euler head distribution and pressure fluctuation amplitude is observed and used to explain the mechanism of intensive pressure fluctuation. The impeller blade with ordinary trailing edge profile, which is the prototype impeller in this study, usually induces wake shedding near the impeller outlet, making the energy distribution less uniform. Because of this, the method of reducing pressure fluctuation by means of improving Euler head distribution uniformity by modifying the impeller blade trailing edge profile is proposed. The impeller blade trailing edges are trimmed in different scales, which are marked as model A, B, and C. As a result of trailing edge trimming, the impeller outlet angles at the pressure side of the prototype of model A, B, and C are 21, 18, 15, and 12 degrees, respectively. The differences in Euler head distribution and pressure fluctuation between the model impellers at nominal flow rate are investigated and analyzed. Experimental verification is also conducted to validate the CFD results. The results show that the blade trailing edge profiling on the pressure side can help reduce pressure fluctuation. The uniformity of Euler head circumferential distribution, which is directly related to the intensity of pressure fluctuation, is improved because the impeller blade outlet angle on the pressure side decreases and thus the velocity components are adjusted when the blade trailing edge profile is modified. The results of the investigation demonstrate that blade trailing edge profiling can be used in the vibration reduction of low specific impellers and in the engineering design of centrifugal pumps.


Author(s):  
Zhifeng Yao ◽  
Min Yang ◽  
Ruofu Xiao ◽  
Fujun Wang

The unsteady flow field and pressure fluctuations in double-suction centrifugal pumps are greatly affected by the wall roughness of internal surfaces. To determine the wall roughness effect, numerical and experimental investigations were carried out. Three impeller schemes for different wall roughness were solved using detached eddy simulation, and the performance and pressure fluctuations resolved by detached eddy simulation were compared with the experimental data. The results show that the effects of wall roughness on the static performance of a pump are remarkable. The head and efficiency of the tested double-suction centrifugal pump are raised by 2.53% and 6.60% respectively as the wall roughness is reduced by means of sand blasting and coating treatments. The detached eddy simulation method has been proven to be accurate for the prediction of the head and efficiency of the double-suction centrifugal pump with roughness effects. The influence of the roughness on pressure fluctuation is greatly dependent on the location relative to the volute tongue region. For locations close to the volute tongue, the peak-to-peak value of the pressure fluctuations of a wall roughness of Ra = 0.10 mm may be 23.27% larger than the case where Ra = 0.02 mm at design flow rate.


Author(s):  
Ahmed Ramadhan Al-Obaidi ◽  
Ali Qubian

Abstract In this current study, the transient numerical calculations using CFD code are carried out under different outlet impeller diameters for the flow field within a centrifugal pump under single-phase and cavitation conditions. Both qualitative and quantitative analyses are carried out on all of these results in order to better understand the flow structure within a centrifugal pump. Also, the investigations using different outlet impeller diameters configurations relating to the static pressure, velocity magnitude, vapour volume fraction variations, as well as pressure fluctuations in both time and frequency domain at the impeller and volute of the pump are analysed. Velocity and static pressure variations of the pump under different outlet impeller diameters range (200, 210 and 220 mm) are investigated. Reliable model is developed and validated, at various pump operating conditions, to analyse the characteristics of pressure fluctuations in both time and frequency domain. Cavitation occurrence, under different outlet impeller diameters and flow rates, are detected and correlated, using a CFD model (volume fraction distributions). Based on the developed model’s findings, at the set operating conditions ranges, the distribution and impact (cavitation and head-wises) of both the pressure and velocity are analysed. The average pressure fluctuation in the volute for do = 210 mm is higher than for do = 200 mm by about 6.74%, also the maximum pressure fluctuation for do = 220 mm is higher than for do = 210 mm by around 7.4%. Furthermore, the maximum pressure fluctuation in the impeller for do = 210 mm is higher than for do = 200 mm by 12.48%, also for do = 220 mm is higher than for do = 210 mm by 10.8%. The developed CFD models are proved valuable tools in identifying and optimizing the pump performance and characterization. The head for when do = 220 mm is higher than for when do = 200 mm under both single-phase and cavitation conditions by around 14.13% and 14.69%. The maximum pressure fluctuation for do = 200 mm is lower than for do = 210 mm by 41.58%. Furthermore, the maximum pressure fluctuation at the impeller for do = 220 mm is higher than the two models. There is a small clearance between the impeller and the volute for this model, leading to the pressure fluctuation amplitudes being higher than the other above models.


2016 ◽  
Vol 2016 ◽  
pp. 1-11 ◽  
Author(s):  
Lei Cao ◽  
Zhengwei Wang ◽  
Yexiang Xiao ◽  
Yongyao Luo

Clearance flows in the sidewall gaps of centrifugal pumps are unsteady as well as main flows in the volute casing and impeller, which may cause vibration and noise, and the corresponding pressure fluctuations are related to the axial clearance size. In this paper, unsteady numerical simulations were conducted to predict the unsteady flows within the entire flow passage of a centrifugal pump operating in the design condition. Pressure fluctuation characteristics in the volute casing, impeller, and sidewall gaps were investigated with three axial clearance sizes. Results show that an axial clearance variation affects the pressure fluctuation characteristics in each flow domain by different degree. The greatest pressure fluctuation occurs at the blade pressure surface and is almost not influenced by the axial clearance variation which has a certainly effect on the pressure fluctuation characteristics around the tongue. The maximum pressure fluctuation amplitude in the sidewall gaps is larger than that in the volute casing, and different spectrum characteristics show up in the three models due to the interaction between the clearance flow and the main flow as well as the rotor-stator interaction. Therefore, clearance flow should be taken into consideration in the hydraulic design of centrifugal pumps.


Author(s):  
Qianqian Li ◽  
Shiyang Li ◽  
Peng Wu ◽  
Bin Huang ◽  
Dazhuan Wu

AbstractDouble-suction centrifugal pumps have been applied extensively in many areas, and the significance of pressure fluctuations inside these pumps with large power is becoming increasingly important. In this study, a double-suction centrifugal pump with a high-demand for vibration and noise was redesigned by increasing the flow uniformity at the impeller discharge, implemented by combinations of more than two parameters. First, increasing the number of the impeller blades was intended to enhance the bounding effect that the blades imposed on the fluid. Subsequently, increasing the radial gap between the impeller and volute was applied to reduce the rotor-stator interaction. Finally, the staggered arrangement was optimized to weaken the efficacy of the interference superposition. Based on numerical simulation, the steady and unsteady characteristics of the pump models were calculated. From the fluctuation analysis in the frequency domain, the dimensionless pressure fluctuation amplitude at the blade passing frequency and its harmonics, located on the monitoring points in the redesigned pumps (both with larger radial gap), are reduced a lot. Further, in the volute of the model with new impellers staggered at 12°, the average value for the dimensionless pressure fluctuation amplitude decreases to 6% of that in prototype pump. The dimensionless root-mean-square pressure contour on the mid-span of the impeller tends to be more uniform in the redesigned models (both with larger radial gap); similarly, the pressure contour on the mid-section of the volute presents good uniformity in these models, which in turn demonstrating a reduction in the pressure fluctuation intensity. The results reveal the mechanism of pressure fluctuation reduction in a double-suction centrifugal pump, and the results of this study could provide a reference for pressure fluctuation reduction and vibration performance reinforcement of double-suction centrifugal pumps and other pumps.


Author(s):  
Jian-Cheng Cai ◽  
Jia-Qi Zhang ◽  
Can Yang

Abstract The 3-D unsteady turbulent flow inside a centrifugal fan and its downstream pipe is investigated at the best efficiency point (BEP) flow rate using the computational fluid dynamics (CFD) package ANSYS FLUENT. The impeller with an outlet diameter of 400 mm has 12 forward curved blades. The computational domain comprises four parts: the inlet part, the impeller, the volute, and the downstream pipe. The flow domain was meshed in ANSYS ICEM-CFD with structured hexahedron cells, and nearly 9 million cells were used. The Detached Eddy Simulation (DES) turbulence modelling approach was employed with this fine enough mesh scheme. The impeller was set as the rotating domain at a speed of 2900 rpm. A sliding mesh technique was applied to the interfaces in order to allow unsteady interactions between the rotating impeller and the stationary parts; the unsteady interactions generate pressure fluctuations inside the centrifugal fan. One impeller revolution is divided into 2048 time steps, in order to capture the transient flow phenomena with high resolution. Monitoring points were set along the volute casing profile, and along the downstream pipe centerline. When the numerical simulation became stable after several impeller revolutions, the statistics of the unsteady flow was initiated with a total of 16384 time steps (8 impeller revolutions) data. The time history data of the pressure and velocity magnitude at the monitoring points were saved and with Fourier transform applied to obtain the frequency spectra. The time-averaged flow fields show clearly the static pressure rises gradually through the impeller, and further recovers from the velocity in the volute, and decreases gradually along the downstream pipe due to the friction. The mean pressure at the pressure side of the impeller blade is larger than it at the suction side, forming the circumferential nonuniform flow pattern. Owing to the forward-curved blades, large velocity region exists around the impellor exit, and the maximum velocity near the trailing edge can reach 1.5u2, where u2 is the circumferential velocity at the impeller outlet. The root mean square (rms) value distribution of pressure fluctuations show that most parts inside the centrifugal fan undergo large pressure fluctuation with the magnitude about 10% of the reference dynamic pressure pref = 0.5ρu22; the maximum value locating at the tongue tip can reach 30% of pref. The pressure fluctuation magnitude decreases quickly along the outlet pipe: after 5D (D is the outlet pipe diameter) the magnitude is 0.5% of pref. The pressure and velocity fluctuation spectra at the monitoring points in the volute show striking discrete components at the blade-passing frequency (BPF) and its 2nd, 3rd harmonics. The BPF component has the maximum value of 15% of pref in the tongue region, and it decreases dramatically along the downstream pipe with the amplitude less than 0.2% of pref after 5D distance.


Author(s):  
Jianping Yuan ◽  
Hongqin He ◽  
Zhixia He ◽  
Shouqi Yuan

The centrifugal pump is one of the most widely used pumps. Lower efficiency, worse cavitation performance and stronger unsteady flow are three main problems for the low-specific-speed centrifugal pumps. Due to unsteady flow within pumps, pressure is fluctuant, which further induces vibration and noise. For a centrifugal pump with different impellers, its characteristics of unsteady flow are also different. In this paper, five different impellers were designed adopting low-specific-speed design method, splitter-blades design method and velocity-coefficient method with a set of performance parameters (Q = 25m3/h, H = 10m, n = 1450r/min). 3D unsteady turbulent flow field within the centrifugal pump was simulated. The periodic fluctuation phenomenon and the unsteady flow characteristics were investigated. The static pressure fluctuation in the volute and at the volute outlet and the instantaneous head changes were showed for the pumps with five different impellers operated at design and off-design conditions. The pressure fluctuation is the strongest near the tongue and is slighter at the volute outlet section. The transient head fluctuation increases with the flow rate. The transient head fluctuation of the pump with the low-specific-speed designed impeller is the biggest, while that of the pump with the normal-designed impeller is the smallest. Among the three splitter-blade impellers, the transient head fluctuation of the impeller with splitter blades leaned to the corresponding suction side of the long blades is the smallest. Eventually, the different design schemes were evaluated using the unsteady flow analysis. These conclusions from this paper can supply some references for the design of low-specific-speed centrifugal pumps considering its pressure fluctuation and flow-induced vibration and noise.


Author(s):  
Ling Zhou ◽  
Weidong Shi ◽  
Ling Bai ◽  
Weigang Lu ◽  
Wei Li

The unsteady flow field in a multistage centrifugal pump was simulated with ANSYS-CFX code based on transient rotor-stator method, and Shear Stress Transport (SST) turbulence model to investigate the pressure fluctuations in the three stages passages. With the Fast Fourier Transform (FFT) analysis, the pressure fluctuations and frequency domains are analyzed and compared between stages. The numerical results show that the pressure fluctuates at the blade passage frequency, and the maximum amplitude of blade passage frequency occurs in the region from the rotor to the stator when the impeller blade gets close to the diffuser vane leading edge. The pressure pulsation period mainly associated with the number of impeller blades, but the influence gradually reduce when the fluids flow into the diffuser. The flow patterns and pressure fluctuation between stags are similar.


Sign in / Sign up

Export Citation Format

Share Document