scholarly journals Dental implant location via surface scanner: a pilot study

2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Miao Zhou ◽  
Hui Zhou ◽  
Shu-yi Li ◽  
Yuan-ming Geng

Abstract Purpose Implant location is performed after placement to verify that the safety of neighboring anatomic structure and the realizability of prosthetic plan. Routine postoperative location is based on radiological scanning and raises the concerns on radiation exposure and inconveniency in practice. In the present study a location method based on surface scanning was introduced and the accuracy of this method was assessed in vitro. Material and methods A total of 40 implants were placed in 10 resin mandible models. The models were scanned with intraoral scanner (IS group) and extraoral scanner (ES group). The implant position was located with fusing the images of surface scanning and cone beam computerized tomography (CBCT) after implant placement. Deviations were measured between positions located by surface scanner and postoperative CBCT with the parameters: central deviation at apex (cda), central deviation at hex (cdh), horizontal deviation at apex (hda), horizontal deviation at hex (hdh), vertical deviation at apex (vda), vertical deviation at hex (vdh) and angular deviation (ad). Results In IS group, the mean value of cda, cdh, hda, hdh, vda, vdh and ad was 0.27 mm, 0.23 mm, 0.12 mm, 0.10 mm, 0.21 mm, 0.19 mm and 0.72°, respectively. In ES group, the mean value of cda, cdh, hda, hdh, vda, vdh and ad was 0.28 mm, 0.25 mm 0.14 mm, 0.11 mm, 0.22 mm, 0.20 mm and 0.68°, respectively. The implant deviations in IS and ES groups were of no significant difference for any of the measurements. Conclusions Dental implant can be located via surface scanner with acceptable accuracy for postoperative verification. Further clinical investigation is needed to assess the feasibility of the method.

2019 ◽  
Vol 9 (16) ◽  
pp. 3373 ◽  
Author(s):  
Seong-Min Kim ◽  
Keunbada Son ◽  
Duk-Yeon Kim ◽  
Kyu-Bok Lee

Compared to traditional implant surgical guides, computer-assisted implant surgical guides can be considered for positioning implants in the final prosthesis. These computer-assisted implant surgical guides can be easily fabricated with personal 3D printers after being designed with implant planning CAD software. Although the accuracy of computer-assisted implant surgical guides fabricated using personal 3D printers is an important factor in their clinical use, there is still a lack of research examining their accuracy. Therefore, this study evaluated the accuracy of computer-assisted implant surgical guides, which were designed using two implant planning CAD software programs (Deltanine and R2gate software) and fabricated with personal 3D printers using a non-radiographic method. Amongst the patients who visited Kyungpook National University Dental Hospital, one patient scheduled to undergo surgery of the left mandibular second premolar was randomly selected. Twenty partially edentulous resin study models were produced using a 3D printer. Using the Deltanine and R2gate implant planning CAD software, 10 implant surgical guides per software were designed and produced using a personal 3D printer. The implants (SIII SA (Ø 4.0, L = 10 mm), Osstem, Busan, Korea) were placed by one skilled investigator using the computer-assisted implant surgical guides. To confirm the position of the actual implant fixture, the study models with the implant fixtures were scanned with a connected scan body to extract the STL files, and then overlapped with the scanned file by connecting the scan body-implant fixture complex. As a result, the mean apical deviation of the Deltanine and R2gate software was 0.603 ± 0.19 mm and 0.609 ± 0.18 mm, while the mean angular deviation was 1.97 ± 0.84° and 1.92 ± 0.52°, respectively. There was no significant difference between the two software programs (p > 0.05). Thus, the accuracy of the personal 3D printing implant surgical guides is in the average range allowed by the dental clinician.


1996 ◽  
Vol 75 (05) ◽  
pp. 772-777 ◽  
Author(s):  
Sybille Albrecht ◽  
Matthias Kotzsch ◽  
Gabriele Siegert ◽  
Thomas Luther ◽  
Heinz Großmann ◽  
...  

SummaryThe plasma tissue factor (TF) concentration was correlated to factor VII concentration (FVIIag) and factor VII activity (FVIIc) in 498 healthy volunteers ranging in age from 17 to 64 years. Immunoassays using monoclonal antibodies (mAbs) were developed for the determination of TF and FVIIag in plasma. The mAbs and the test systems were characterized. The mean value of the TF concentration was 172 ± 135 pg/ml. TF showed no age- and gender-related differences. For the total population, FVIIc, determined by a clotting test, was 110 ± 15% and the factor VIlag was 0.77 ± 0.19 μg/ml. FVII activity was significantly increased with age, whereas the concentration demonstrated no correlation to age in this population. FVII concentration is highly correlated with the activity as measured by clotting assay using rabbit thromboplastin. The ratio between FVIIc and FVIIag was not age-dependent, but demonstrated a significant difference between men and women. Between TF and FVII we could not detect a correlation.


Author(s):  
Eisha Imran ◽  
Faisal Moeen ◽  
Beenish Abbas ◽  
Bakhtawar Yaqoob ◽  
Mehreen Wajahat ◽  
...  

Abstract Objectives The study aimed to evaluate and compare various commercially available local anesthetic solutions. Materials and Methods A total of 150 commercially available local anesthetic cartridges of similar composition (2% lidocaine with epinephrine 1:100,000) were randomly collected and divided into 3 groups. The designations of groups were selected from their product names such that each group consisted of 60 cartridges. Group S (Septodont, France) Group M (Medicaine, Korea) and Group H (HD-Caine, Pakistan). The samples were divided into five sub-groups, each consisting of 10 cartridges from each group to investigate each parameter. Results The acquired data was statistically analyzed and compared (using SPSS version 12). Compositional analysis revealed a non-significant (P>0.05) difference when the three Groups were compared with standard lidocaine and epinephrine solutions. The mean pH values of samples from group S, M and H respectively fell within the range of pH values of commercially available solutions. Non-significant difference in EPT values of Group S and H was found when efficacy was compared (p = 0.3), however a significant difference (p < 0.01) was observed in contrast to Group M. Anti-bacterial activity was observed in all the group and a non-significant difference in cell viability values of Group S and M was found (p = 0.6), while the difference was significant in comparison to Group H. Conclusion Within the limitations of these investigations, it appears that the properties of different manufacturers fall within the recommended ranges as mentioned in literature and do not appear to be statistically different in the variables we have tested.


Author(s):  
Yuko Komuro ◽  
Yuji Ohta

Conventionally, the strength of toe plantar flexion (STPF) is measured in a seated position, in which not only the target toe joints but also the knee and particularly ankle joints, are usually restrained. We have developed an approach for the measurement of STPF which does not involve restraint and considers the interactions of adjacent joints of the lower extremities. This study aimed to evaluate this new approach and comparing with the seated approach. A thin, light-weight, rigid plate was attached to the sole of the foot in order to immobilize the toe area. Participants were 13 healthy young women (mean age: 24 ± 4 years). For measurement of STPF with the new approach, participants were instructed to stand, raise the device-wearing leg slightly, plantar flex the ankle, and push the sensor sheet with the toes to exert STPF. The sensor sheet of the F-scan II system was inserted between the foot sole and the plate. For measurement with the seated approach, participants were instructed to sit and push the sensor with the toes. They were required to maintain the hip, knee, and ankle joints at 90°. The mean values of maximum STPF of the 13 participants obtained with each approach were compared. There was no significant difference in mean value of maximum STPF when the two approaches were compared (new: 59 ± 23 N, seated: 47 ± 33 N). The coefficient of variation of maximum STPF was smaller for data obtained with the new approach (new: 39%, seated: 70%). Our simple approach enables measurement of STPF without the need for the restraints that are required for the conventional seated approach. These results suggest that the new approach is a valid method for measurement of STPF.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Tilahun Fufa Debela ◽  
Zerihun Asefa Hordofa ◽  
Aster Berhe Aregawi ◽  
Demisew Amenu Sori

Abstract Background The consequences of obstetric fistula on affected women are more than the medical condition. It has extensive physical, psychological, social, and economic consequences on them. Obstetric fistula affects the entire health and entire life of women. Women suffering from obstetric fistula are often abandoned by her partner, relatives, and the community. This study aimed to determine the quality of life of obstetrics fistula patients before and after surgical repair. Methods Institutional-based prospective, before and after study design was conducted in the Jimma University Medical Center from November 1, 2019–October 30, 2020. A face-to-face interview was conducted with fistula patients who visited Jimma University Medical center, fistula clinic during the study period. All fistula patients were included in the study. Accordingly, 78 women who underwent surgical repair were interviewed. The means and the standard deviation were computed using conventional statistics formulas. The unpaired t-test was used to compare two independent means, and one-way analysis of variance (ANOVA) was used to compare the quality of life before repair and after a successful repair. Linear regression analysis was done for identifying determinants of quality of life. A P value of 0.05 will be considered statistical significance. Result The overall quality of life of women was 58.17 ± 7.2 before the surgical repair and 71.20 ± 10.79 after surgical repair. The result indicates there is a significant difference in the mean value of pre and post-operative (P < 0.001). The overall satisfaction of women with their health status before the surgical repair was 22.5 ± 1.30and it has increased to 53.0 ± .90after surgical repair. The physical health dimension score was 16.51 ± 5.27 before the surgical repair while it has increased to 21.77 ± 5.38 after the surgical repair. The score of the social domain before the surgical repair was 5.19 ± 1.34 and it has increased to 7.13 ± 3.67 after the surgical repair. The score of the environmental health domain was 17.41 ± 2.89 before the surgery while it also increased to 21.65 ± 4.04 after the surgical repair. The results have shown there was a significant difference in the mean values of pre and post-operatives in both social and environmental scores (P < 0.001). The score of the psychological health domain before the surgery was 19.06 ± 1.46 and it was increased to 19.84 ± 3.21 after the surgical repair. The result showed there is a significant difference in mean value pre and post-operative (P = 0.048), though it is a slight improvement compared to other domains. Conclusion The overall quality of life of the patient with fistula was improved after successful surgical repair. Although all domains of quality of life had shown significant improvement after successful surgical repair, the psychological domain showed slight improvement.


Biology ◽  
2021 ◽  
Vol 10 (5) ◽  
pp. 358
Author(s):  
Javier Aragoneses ◽  
Ana Suárez ◽  
Nansi López-Valverde ◽  
Francisco Martínez-Martínez ◽  
Juan Manuel Aragoneses

The aim of this study was to evaluate the effect of implant surface treatment with carboxyethylphosphonic acid and fibroblast growth factor 2 on the bone–implant interface during the osseointegration period in vivo using an animal model. The present research was carried out in six minipigs, in whose left tibia implants were inserted as follows: eight implants with a standard surface treatment, for the control group, and eight implants with a surface treatment of carboxyethylphosphonic acid and immobilization of FGF-2, for the test group. At 4 weeks after the insertion of the implants, the animals were sacrificed for the histomorphometric analysis of the samples. The means of the results for the implant–bone contact variable (BIC) were 46.39 ± 17.49% for the test group and 34.00 ± 9.92% for the control group; the difference was not statistically significant. For the corrected implant–bone contact variable (BICc), the mean value of the test group was 60.48 ± 18.11%, and that for the control group, 43.08 ± 10.77%; the difference was statistically significant (p-value = 0.035). The new bone formation (BV/TV) showed average results of 27.28 ± 3.88% for the test group and 26.63 ± 7.90% for the control group, meaning that the differences were not statistically significant (p-value = 0.839). Regarding the bone density at the interthread level (BAI/TA), the mean value of the test group was 32.27 ± 6.70%, and that of the control group was 32.91 ± 7.76%, with a p-value of 0.863, while for the peri-implant density (BAP/TA), the mean value of the test group was 44.96 ± 7.55%, and that for the control group was 44.80 ± 8.68%, without a significant difference between the groups. The current research only found a significant difference for the bone–implant contact at the cortical level; therefore, it could be considered that FGF-2 acts on the mineralization of bone tissue. The application of carboxyethylphosphonic acid on the surface of implants can be considered a promising alternative as a biomimetic coating for the immobilization of FGF-2. Despite no differences in the new bone formation around the implants or in the interthread or peri-implant bone density being detected, the biofunctionalization of the implant surface with FGF-2 accelerates the mineralization of the bone–implant interface at the cortical level, thereby reducing the osseointegration period.


2012 ◽  
Vol 83 (1) ◽  
pp. 152-157 ◽  
Author(s):  
Erika L. Silva-Benítez ◽  
Veronica Zavala-Alonso ◽  
Gabriel A. Martinez-Castanon ◽  
Juan P. Loyola-Rodriguez ◽  
Nuria Patiño-Marin ◽  
...  

Abstract Objective: To study the shear bond strength (SBS), sites of failure, and micromorphology of bonded molar tubes used on teeth affected by dental fluorosis. Materials and Methods: This in vitro study included 140 first molars classified according to Dean's index for dental fluorosis. Samples were divided into seven groups: (1) healthy teeth etched for 15 seconds, (2) teeth with moderate fluorosis (MOF) etched for 15 seconds, (3) teeth with MOF etched for 150 seconds, (4) teeth with MOF microabrasion etched for 15 seconds, (5) teeth with severe fluorosis (SEF) etched for 15 seconds, (6) teeth with SEF etched for 150 seconds, and (7) teeth with SEF microabrasion etched for 15 seconds. All samples were incubated and were then submitted to the SBS test and evaluated with the modified adhesive remnant index (ARI) and analyzed by using a scanning electronic microscope. Results: The SBS mean value for healthy enamel was 20 ± 10.2 MPa. For the group with MOF, the etched 150-second mean value was the highest (19 ± 7.6 MPa); for the group with SEF treated with microabrasion and etched for 15 seconds, the mean value was (13 ± 4.1 MPa). Significant differences (P ≤ .05) were found in the ARI between healthy and fluorosed groups. Conclusions: Fluorotic enamel affects the adhesion of bonded molar tubes. The use of overetching in cases of MOF and the combination of microabrasion and etching in SEF provides a suitable adhesion for fixed appliance therapy.


2021 ◽  
Vol 95 ◽  
Author(s):  
C.I. Cortés-Martínez ◽  
A.I. Rodríguez-Hernández ◽  
M.R. López-Cuellar ◽  
N. Chavarría-Hernández

Abstract The use of native entomopathogenic nematodes as biocontrol agents is a strategy to decrease the environmental impact of insecticides and achieve sustainable agriculture crops. In this study, the effect of the surface culture of Steinernema sp. JAP1 over two solid media at 23–27°C on infective juvenile (IJ) production and pathogenicity against Galleria mellonella larvae were investigated. First, the bacterial lawn on the surface of the media with egg yolk (P2) or chicken liver (Cl) were incubated in darkness at 30°C for 48 and 72 h, and 100 surface-sterilized IJs were added. Four harvests were conducted within the next 35 days and the mean accumulated production was superior on Cl (210 × 103 IJs) than on P2 (135 × 103 IJs), but the productivity decreased up to 10% when the incubation time of the bacterial lawn was of 72 h. The mean pathogenicity of in vitro- and in vivo-produced IJs were of 47–64% and 31%, respectively. It is worth noting that none of the two solid media had a statistically significant difference in IJ pathogenicity. Considering that the maximum multiplication factor of IJs on solid media was 2108 and that the pathogenicity against G. mellonella was outstanding, Steinernema sp. has a good potential for in vitro mass production.


2017 ◽  
Vol 10 (2) ◽  
pp. 11
Author(s):  
Bahruddin Thalib ◽  
Edy Machmud ◽  
Mochammad Dharmautama ◽  
Ervina Sari Surya ◽  
Asmawati Asmawati ◽  
...  

OBJECTIVE: The success of a dental dental implant treatment focuses on a phenomenon called osseointegration. Evaluation of Bone Area (BA) and Bone-Dental implant Contact (BIC) through histomorphometric analysis is the most widely used parameter to measure osseointegration. The aim of this study was to see post-placement Bone Dental implant Contact (BIC) value of dental implant coated and not coated with PRP.MATERIALS & METHODS: This study was an experimental laboratory conducted at Laboratory of Veterinary Faculty, Hasanuddin University. The sample was baby buck rabbit, aged 4-8 months old, weight 1500–2000 gram, divided into 2 groups each group consist of 12 rabbit, control group not coated with PRP and treatment group coated with PRP. Data analysis using SPSS version 20.0 (SPSS Inc., Chicago, IL, USA).RESULTS: There was a significant difference between the mean BIC values and the 20% increase in BIC values in LP1, LP2 and LP3 between treatment and control group on day 0, 3, 7, and 14.CONCLUSIONS: There was a difference in the average of post-placement BIC value of dental implant coated and not coated with PRP.


2004 ◽  
Vol 12 (4) ◽  
pp. 344-348 ◽  
Author(s):  
Eduardo Bresciani ◽  
Terezinha de Jesus Esteves Barata ◽  
Ticiane Cestari Fagundes ◽  
Akimi Adachi ◽  
Marina Martins Terrin ◽  
...  

The aim of this study was to compare, in different periods of time, the compressive and diametral tensile strength of a traditional high viscous glass ionomer cement: Fuji IX (GC Corporation), with two new Brazilian GIC's: Vitro-Molar (DFL) and Bioglass R (Biodinamica), all indicated for the Atraumatic Restorative Treatment (ART) technique. Fifteen disk specimens (6.0mm diameter x 3.0mm height) for the diametral tensile strength (DTS) test and fifteen cylindrical specimens (6.0mm diameter x 12.0mm height) for the compressive strength (CS) test were made of each GIC. Specimens were stored in deionized water at 37º C and 100% of humidity in a stove until testing. Five specimens of each GIC were submitted to CS and DTS test in each period, namely 1 hour, 24 hours and 7 days. The specimens were tested in a testing machine (Emic) at a crosshead speed of 1.0mm/min for CS and 0.5mm/min for the DTS test until failure occurred. The data were submitted to two-way ANOVA and Tukey tests (alpha=0.05). The mean CS values ranged from 42.03 to 155.47MPa and means DTS from 5.54 to 13.72 MPa, with test periods from 1h to 7 days. The CS and DTS tests showed no statistically significant difference between Fuji IX and Vitro Molar, except for CS test at 1-hour period. Bioglass R had lowest mean value for CS of the cements tested. In DTS test Bioglass R presented no statistically significant differences when compared with all others tested GICs at 1-hour period and Bioglass R presented no difference at 24-hour and 7-day periods when compared to Vitro-Molar. Further studies to investigate other physical properties such as fracture toughness and wear resistance, as well as chemical composition and biocompatibility, are now needed to better understand the properties of these new Brazilian GIC's.


Sign in / Sign up

Export Citation Format

Share Document