scholarly journals Mechanical stability study of three techniques used in the fixation of transverse and oblique metaphyseal-diaphyseal junction fractures of the distal humerus in children: a finite element analysis

2020 ◽  
Vol 15 (1) ◽  
Author(s):  
Chuang Liu ◽  
Allieu Kamara ◽  
Tianjing Liu ◽  
Yunhui Yan ◽  
Enbo Wang
2014 ◽  
Vol 14 (05) ◽  
pp. 1450063 ◽  
Author(s):  
D. F. M. PAKVIS ◽  
D. JANSSEN ◽  
B. W. SCHREURS ◽  
N. VERDONSCHOT

Acetabular stress shielding may be a failure mechanism of acetabular constructs promoting osteolysis, aseptic loosening and failure. We used three-dimensional finite element analysis (FEA) to evaluate the effect of flexible sockets on acetabular stress shielding. The sockets were made of (1) full polyethylene (PE), (2) PE with a metal bearing and (3) a PE insert with a metal backing was used as a traditional stiff implant. We compared the strain energy density and interfacial micro-motions between bone and cementless sockets during walking. In our FEA model, the most elastic socket (case 1) showed the highest levels of micro-motion during walking (400 μm). The most rigid socket (case 3) showed smaller areas of high micro-motions. Assuming a threshold for ingrowth of 50 microns, the flexible cup showed an ingrowth area of almost 40%, whereas the other two cases showed stable areas covering 60% of the total bone–component interface. Furthermore, we found that the introduction of an implant generates a very different strain pattern directly around the implant as compared with the intact case, which has a horse-shoe shaped cartilage layer in the acetabulum. This difference was not affected much by the stiffness of the implant; a more flexible implant resulted in only slightly higher strain levels. Bone strains over 1.5 mm from the cup showed physiological values and were not affected by the stiffness of the implant. Hence, this study shows that the physiological strain patterns are not obtained in the direct periprosthetic bone, regardless of the stiffness of the material.


Author(s):  
M. Wettergreen ◽  
B. Bucklen ◽  
B. Starly ◽  
E. Yuksel ◽  
W. Sun ◽  
...  

Guided tissue regeneration focuses on the implantation of a scaffold architecture, which acts as a conduit for stimulated tissue growth. Successful scaffolds must fulfill three basic requirements: provide architecture conducive to cell attachment, support adequate fluid perfusion, and provide mechanical stability during healing and degradation. The first two of these concerns have been addressed successfully with standard scaffold fabrication techniques. In instances where load bearing implants are required, such as in treatment of the spine and long bones, application of these normal design criteria is not always feasible. The scaffold may support tissue invasion and fluid perfusion but with insufficient mechanical stability, likely collapsing after implantation as a result of the contradictory nature of the design factors involved. Addressing mechanical stability of a resorbable implant requires specific control over the scaffold design. With design and manufacturing advancements, such as rapid prototyping and other fabrication methods, research has shifted towards the optimization of scaffolds with both global mechanical properties matching native tissue, and micro-structural dimensions tailored to a site-specific defect. While previous research has demonstrated the ability to create architectures of repetitious microstructures and characterize them, the ideal implant is one that would readily be assembled in series or parallel, each location corresponding to specific mechanical and perfusion properties. The goal of this study was to design a library of implantable micro-structures (unit blocks) which may be combined piecewise, and seamlessly integrated, according to their mechanical function. Once a library of micro-structures is created, a material may be selected through interpolation to obtain the desired mechanical properties and porosity. Our study incorporated a linear, isotropic, finite element analysis on a series of various micro-structures to determine their material properties over a wide range of porosities. Furthermore, an analysis of the stress profile throughout the unit blocks was conducted to investigate the effect of the spatial distribution of the building material. Computer Aided Design (CAD) and Finite Element Analysis (FEA) hybridized with manufacturing techniques such as Solid Freeform Fabrication (SFF), is hypothesized to allow for virtual design, characterization, and production of scaffolds optimized for tissue replacement. This procedure will allow a tissue engineering approach to focus solely on the role of architectural selection by combining symmetric scaffold micro-structures in an anti-symmetric or anisotropic manner as needed. The methodology is discussed in the sphere of bone regeneration, and examples of cataloged shapes are presented. Similar principles may apply for other organs as well.


2021 ◽  
Vol 12 ◽  
Author(s):  
Yasamin Seddighi ◽  
Hai-Chao Han

The stability of blood vessels is essential for maintaining the normal arterial function, and loss of stability may result in blood vessel tortuosity. The previous theoretical models of artery buckling were developed for circular vessel models, but arteries often demonstrate geometric variations such as elliptic and eccentric cross-sections. The objective of this study was to establish the theoretical foundation for noncircular blood vessel bent (i.e., lateral) buckling and simulate the buckling behavior of arteries with elliptic and eccentric cross-sections using finite element analysis. A generalized buckling equation for noncircular vessels was derived and finite element analysis was conducted to simulate the artery buckling behavior under lumen pressure and axial tension. The arterial wall was modeled as a thick-walled cylinder with hyper-elastic anisotropic and homogeneous material. The results demonstrated that oval or eccentric cross-section increases the critical buckling pressure of arteries and having both ovalness and eccentricity would further enhance the effect. We conclude that variations of the cross-sectional shape affect the critical pressure of arteries. These results improve the understanding of the mechanical stability of arteries.


2007 ◽  
Vol 20 (04) ◽  
pp. 285-290 ◽  
Author(s):  
D. P. Comiskey ◽  
B. Mac Donald ◽  
C. B. Garvan ◽  
W. T. Mc Cartney

SummaryFourteen Spaniels that presented with an intercondylar fracture of the distal humerus were managed using a lateral plate and an additional pin in twelve cases. Fixation of the fracture was achieved using a plate applied laterally which incorporated the transcondylar lag screw in the most distal hole. Of the 14 cases, two had poor results, one of which was a bilateral case, whilst the remaining 12 cases had good or very good results with only occasional stiffness or lameness. Finite element (FE) modelling of a distal humerus was generated, and loading of fracture repairs using a lateral plate and caudal plate was completed in a comparative study to determine which fixation method resisted micro-motion most effectively. Finite element analysis revealed that the lateral plate fixation provided significantly more resistance to micro movement at the fracture site that the caudal plate fixation, with 40% more micro-motion in the latter.


2016 ◽  
Vol 115 ◽  
pp. 96-99 ◽  
Author(s):  
Hoon-Hwe Cho ◽  
Yu-chen Karen Chen-Wiegart ◽  
David C. Dunand

2019 ◽  
Vol 5 (1) ◽  
pp. 553-556
Author(s):  
Christopher Fleischmann ◽  
Irina Leher ◽  
Reinhold Hartwich ◽  
Marc Hainke ◽  
Stefan Sesselmann

AbstractAlthough osteosynthesis plates rarely break, such cases still occur. Since the construction of these plates is mainly focussing on the best fit for anatomical structures, they may not provide optimal mechanical stability. It should be considered whether they might be changed in terms of e.g. hole size and number. Finite element analysis can help to estimate whether the plates will withstand loads or break. However, these analyses can be very time-consuming. To counteract this problem, a new software solution (ANSYS Discovery Live) has been established for estimation of stresses in real time. In this study the accuracy of the new software was compared to a conventional finite element analysis software solution to investigate whether this software solution provides appropriate accuracy to be used for medical applications.


2017 ◽  
Author(s):  
Shafia Tabassum ◽  
Ahmar Murtaza ◽  
Hasan Ali ◽  
Zia Mohy Uddin ◽  
Syedah Sadaf Zehra