scholarly journals Alternative method’s results for the non targeted determination of xenobiotics in food by means of high resolution and accuracy mass spectrometry

2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Rossana Scarpone ◽  
Rachele Rocchi ◽  
Federico Bacà ◽  
Roberta Rosato ◽  
Francesco Chiumiento ◽  
...  

AbstractThe application of a high resolution and accurate mass spectrometry (HRAMS) approach to detect xenobiotics in different food matrices by means of non targeted determination by UHPLC-Orbitrap followed by data processing analysis was described. Three case studies were reported to demonstrate the possibility to identify unexpected substances in different food commodities overcomes targeted method. This innovative approach could lay the foundation for its applicability to routine analysis in the near future giving the possibility to open new horizons to the research of a wide range of xenobiotics.

2020 ◽  
Vol 86 (8) ◽  
pp. 23-31
Author(s):  
V. G. Amelin ◽  
D. S. Bolshakov

The goal of the study is developing a methodology for determination of the residual amounts of quaternary ammonium compounds (QAC) in food products by UHPLC/high-resolution mass spectrometry after water-acetonitrile extraction of the determined components from the analyzed samples. The identification and determination of QAC was carried out on an «UltiMate 3000» ultra-high-performance liquid chromatograph (Thermo Scientific, USA) equipped with a «maXis 4G» high-resolution quadrupole-time-of-flight mass spectrometric detector and an ion spray «ionBooster» source (Bruker Daltonics, Germany). Samples of milk, cheese (upper cortical layer), dumplings, pork, chicken skin and ground beef were used as working samples. Optimal conditions are specified for chromatographic separation of the mixture of five QAC, two of them being a mixture of homologues with a linear structure (including isomeric forms). The identification of QAC is carried out by the retention time, exact mass of the ions, and coincidence of the mSigma isotopic distribution. The limits for QAC detection are 0.1 – 0.5 ng/ml, the determination limits are 1 ng/ml for aqueous standard solutions. The determinable content of QAC in food products ranges within 1 – 100 ng/g. The results of analysis revealed the residual amount of QAC present in all samples, which confirms data of numerous sources of information about active use of QAC-based disinfectants in the meat and dairy industry. The correctness of the obtained results is verified by introduction of the additives in food products at a level of 10 ng/g for each QAC. The relative standard deviation of the analysis results does not exceed 0.18. The duration of the analysis is 30 – 40 min.


Sign in / Sign up

Export Citation Format

Share Document