scholarly journals Anatomical and functional outcomes of subthreshold micropulse laser versus intravitreal ranibizumab injection in treatment of diabetic macular edema

Author(s):  
Amr Abdelrahman ◽  
Wagiha Massoud ◽  
Ahmed Mohamed Kamal Elshafei ◽  
Mahmoud Genidy ◽  
Raafat Mohyeldeen Abdelrahman Abdallah

Abstract Background To compare the therapeutic effects of subthreshold micropulse laser (SML) versus intravitreal injection of ranibizumab in treatment of diabetic macular edema (DME) both anatomically using optical coherence tomography (OCT) and functionally using best corrected visual acuity (BCVA) and multifocal electroretinogram (mfERG). Methods his study was an interventional prospective randomized comparative study. The study included 120 eyes classified into 3 groups: Group 1 included 40 eyes of 28 patients treated by SML laser, group 2 included 40 eyes of 32 patients treated by intravitreal injection of ranibizumab, and group 3 (control group for mfERG) included 40 eyes of 20 patients with diabetes mellitus (DM) of more than 10 year duration with no signs of diabetic retinopathy (DR). BCVA measurements, OCT and mfERG were done for the cases before and after interference and were followed up for 6 months Results By the end of the follow up period, BCVA significantly improved by 31% in group 1 vs 93% in group 2 with a statistically highly significant difference between the two groups (p value < 0.001). There was also a significant decrease in central subfield thickness in both groups with more reduction in group 2 compared with group 1 (p value < 0.001). There was a significant improvement in P1 amplitude of mf-ERG in group 2 (p value < 0.002) with no significant improvement in group 1. There was a significant decrease in P1 implicit time in group 2 (p value < 0.001) while there was no significant decrease in group1. Conclusions Intravitreal injection of ranibizumab is a superior treatment modality for DME compared with SML regarding both anatomical and functional outcomes. Trial registration: This study has been approved by the local ethical committee of faculty of medicine of Minia University and retrospectively registered at the clinical trial gov. with Identifier: NCT04332133.

2021 ◽  
Vol 4 (2) ◽  
pp. 106
Author(s):  
Melvina Nidya Sandra ◽  
Yumni Shabrina ◽  
Tri Wahyu Widayanti ◽  
Retno Ekantini ◽  
Agus Supartoto ◽  
...  

Introduction: To evaluate whether the combination of diclofenac eye drops and bevacizumab intravitreal injection would provide additional benefits over bevacizumab alone in the treatment of naïve diabetic macular edema (DME). Methods: A total of 43 patients were enrolled consecutively and randomized into two groups to receive combination treatment with intravitreal bevacizumab and topical diclofenac (group 1) or bevacizumab alone (group 2). Group 1 patients received single bevacizumab intravitreal injection and got self-administered diclofenac eye drop four times daily for one month. Group 2 patients received single bevacizumab intravitreal injection alone. Outcome data were obtained from patient visits at baseline and at 1 month after bevacizumab intravitreal injection. All patients underwent measurement of best corrected visual acuity (BCVA), a complete eye examination, and measurement of central macular thickness (CMT). Result: The mean reduction in CMT in the combination group was 130.42±32.57 µm (p<0.01), while in the bevacizumab alone group the reduction was 141.38±45.27 µm (p<0.01), there is no significant difference between the two groups (p=0.866). The mean improvement of BCVA was 0.32±0.10 log Mar in the combination group and 0.26±0.12 in group 2, there is no significant difference between the two groups (p=0.691). There was no adverse ocular event in the two groups. Conclusion: In patients with naïve DME, adding diclofenac eye drop as adjuvant of bevacizumab intravitreal injection are less likely to have a meaningful effect on reducing the central macular thickness. Keywords: Diabetic macular edema, NSAID, diclofenac, anti-VEGF, bevacizumab, central macular thickness


2021 ◽  
Vol 10 (2) ◽  
pp. 50-58
Author(s):  
Beatriz Oliveira Lopes ◽  
Margarida Sena Brizido ◽  
Florence Aerts ◽  
Susana Morais Pina ◽  
Pedro Santana Simoes ◽  
...  

Background: This study aimed to investigate retinal imaging biomarkers, such as disorganization of the retinal inner layers (DRIL) and/or ellipsoid zone (EZ) disruption by spectral domain optical coherence tomography (SD-OCT), and functional outcomes in eyes treated with 0.2 µg/day of a fluocinolone acetonide intravitreal implant (FAc) after an insufficient response to previous treatments. Methods: This was a retrospective comparative study of 18 eyes (15 patients) with persistent and/or recurrent diabetic macular edema (DME) treated with FAc. Eyes were divided according to the number of prior intravitreal treatments: group 1 (n = 8) with less than or equal to 6 injections (early switch) and group 2 (n = 10) with > 6 injections (late switch). Outcomes included percentage of eyes with DRIL and/or EZ disruption at baseline and analysis of the best corrected visual acuity (BCVA) using ETDRS letters, central macular thickness (CMT), DRIL, and EZ disruption at the last observation. Results: Group 2 revealed a significantly higher percentage of DRIL and/or EZ disruption than group 1 (P < 0.05). At the last observation, group 1 revealed a higher percentage of eyes achieving vision stability/improvement, gaining greater than or equal to15 letters, and achieving greater than or equal to 70 letters (P > 0.05 for all comparisons). The mean BCVA gain was 8.8 and 0.7 letters for groups 1 and 2 (P = 0.397). Both groups revealed a significant mean CMT reduction (>20% reduction from the baseline value), without a significant statistical difference between them (P = 0.749). After treatment, most eyes from both groups showed resolution of DRIL and EZ disruption. Conclusions: Patients with DME presenting with a lower percentage of DRIL and/or EZ disruption at baseline had better functional outcomes, supporting the possible benefit of an early switch to FAc after insufficient response to previous treatments. Future randomized studies with a larger patient cohort are warranted to confirm our conclusions. How to cite this article: Lopes BO, Brizido MS, Aerts F, Pina SM, Simoes PS, Miranda MI. Prognostic biomarkers of chronic diabetic macular edema treated with a fluocinolone acetonide intravitreal implant. Med Hypothesis Discov Innov Ophthalmol. 2021 Summer; 10(2): 50-58. https://doi.org/10.51329/mehdiophthal1421


2021 ◽  
Vol 10 (14) ◽  
pp. 3134
Author(s):  
Luisa Frizziero ◽  
Andrea Calciati ◽  
Giulia Midena ◽  
Tommaso Torresin ◽  
Raffaele Parrozzani ◽  
...  

Subthreshold micropulse laser treatment has become a recognized option in the therapeutic approach to diabetic macular edema. However, some yet undefined elements pertaining to its mechanism of action and most effective treatment method still limit its clinical diffusion. We reviewed the current literature on subthreshold micropulse laser treatment, particularly focusing on its effects on the modulation of retinal neuroinflammation. Subthreshold micropulse laser treatment seems to determine a long-term normalization of specific retinal neuroinflammatory metabolic pathways, contributing to the restoration of retinal homeostasis and the curtailing of local inflammatory processes. Optimized and standardized parameters ensure effective and safe treatment.


Author(s):  
Claudio Furino ◽  
Alfredo Niro ◽  
Michele Reibaldi ◽  
Maria Oliva Grassi ◽  
Francesco Boscia ◽  
...  

Purpose: Different patterns of diabetic macular edema (DME) suggest different pathogenesis and drug response. We evaluated the outcomes after intravitreal dexamethasone (DEX) implant for DME with or without serous retinal detachment (SRD). Methods: In this retrospective study, 22 naïve patients (23 eyes) with DME who underwent a single DEX implant were evaluated. Based on the optical coherence tomographic pattern of DME, 12 eyes had a cystoid macular edema pattern (Group 1) and 11 eyes had an SRD pattern (Group 2). The best-corrected visual acuity (BCVA), central retinal thickness (СRТ), central retinal volume (CRV), SRD height (SRDh), and intraocular pressure (IOP) were recorded before and at two and four months after the treatment. Results: There were no significant differences between the groups regarding demographic, clinical data and outcomes at baseline. In Group 1, the CRT and CRV significantly decreased at two months (P = 0.002 and P = 0.01, respectively), while the BCVA significantly improved at four months (P = 0.03). In Group 2, the CRT and CRV significantly improved (P < 0.01 and P ≤ 0.01, respectively) during the follow-up period. At four months, both groups showed a recurrence of DME, Group 1 in particular (two-month CRT reduction, –149 ± 127 μm vs four-month CRT reduction, –72 ± 174 μm; P = 0.04). The mean reduction in CRV was significantly different at four months (Group 1, –0.49 ± 1.7 mm3 vs Group 2, –1.3 ± 1.3 mm3; P = 0.04). In Group 2, the SRDh significantly decreased at two (P = 0.01) and four months (P = 0.01). Four cases with elevated IOP were managed. Conclusion: DEX implants were found to be effective in different patterns of DME. The SRD pattern may predict a longer-lasting morphologic efficacy.


2019 ◽  
Vol 39 (6) ◽  
Author(s):  
Edoardo Midena ◽  
Silvia Bini ◽  
Luisa Frizziero ◽  
Elisabetta Pilotto ◽  
Graziana Esposito ◽  
...  

Abstract Purpose: To determine if aqueous humour (AH) concentrations of Retinal Pigment Epithelium (RPE)’s biomarkers are modified after subthreshold micropulse laser (SMPL) treatment of diabetic macular edema (DME). Methods: Naïve DME and healthy subjects were enrolled. All DME patients received SMPL treatments (577-nm yellow light, 5% duty cycle of 0.2 s, power 250 mW), according to study protocol. AH of DME eyes was sampled at baseline and periodically after first SMPL treatment. Control eyes were sampled before cataract surgery. Pigment Epithelium Derived Factor (PEDF) and Erythropoietin (EPO) were quantified with glass-chip protein array. Results: Eighteen DME patients (central retinal thickness ≤ 400 μm on Spectral Domain Optical Coherence Tomography (SD-OCT)) and ten controls were enrolled. The main exclusion criteria were high refractive error, proliferative diabetic retinopathy, glaucoma and neurodegenerative disorders. PEDF concentration was decreased in DME patients at baseline versus controls (P=0.012), while EPO was increased (P=0.029). Both molecules’ concentrations remained stable during follow-up after treatments, compared with DME-baseline. Conclusions: The AH concentrations of RPE biomarkers were significantly different in DME treatment-naïve eyes versus controls. The expression of PEDF and EPO remained unchanged after treatments with SMPL in DME eyes. These data are relevant for future research and applications of SMPL.


Sign in / Sign up

Export Citation Format

Share Document