Electromembrane Extraction in Analytical Toxicology

Author(s):  
Marothu Vamsi Krishna ◽  
Kantamaneni Padmalatha ◽  
Gorrepati Madhavi
2019 ◽  
Vol 26 (1) ◽  
pp. 177-196 ◽  
Author(s):  
Mateusz Kacper Woźniak ◽  
Marek Wiergowski ◽  
Jacek Namieśnik ◽  
Marek Biziuk

Background:Ethyl alcohol is the most popular legal drug, but its excessive consumption causes social problems. Despite many public campaigns against alcohol use, car accidents, instances of aggressive behaviour, sexual assaults and deterioration in labor productivity caused by inebriated people is still commonplace. Fast and easy diagnosis of alcohol consumption is required in order to introduce proper and effective therapy, and is crucial in forensic toxicology analysis. The easiest method to prove alcohol intake is determination of ethanol in body fluids or in breath. However, since ethanol is rapidly metabolized in the human organism, only recent consumption can be detected using this method. Because of that, the determination of alcohol biomarkers was introduced for monitoring alcohol consumption over a wider range of time.Objective:The objective of this study was to review published studies focusing on the sample preparation methods and chromatographic or biochemical techniques for the determination of alcohol biomarkers in whole blood, plasma, serum and urine.Methods:An electronic literature search was performed to discuss possibilities and limitations of application of alcohol biomarkers in toxicological analysis.Results:Authors described the markers of alcohol consumption such as: ethanol, its nonoxidative metabolites (ethyl glucuronide, ethyl sulfate, phosphatidylethanol, ethyl phosphate, fatty acid ethyl esters) and oxidative metabolites (acetaldehyde and acetaldehyde adducts). We also discussed issues concerning the detection window of these biomarkers, and possibilities and limitations of their use in routine analytical toxicology for monitoring alcohol consumption or sobriety during alcohol therapy.


2021 ◽  
Author(s):  
Hang Mei ◽  
Huajing Liu ◽  
Qianqian Shang ◽  
Ying Dong ◽  
Stig Pedersen-Bjergaard ◽  
...  

A versatile organic-solvent-free electromembrane extraction (EME) system, which could be successfully used for the extraction of both basic and acidic analytes, is proposed based on semi-interpenetrating polymer networks.


Author(s):  
Cong Liu ◽  
Daixin Huang ◽  
Liuqian Yang ◽  
Shifan Wu ◽  
Xiantao Shen ◽  
...  

2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Wajid Ali Khan ◽  
Muhammad Balal Arain ◽  
Hashmat Bibi ◽  
Mustafa Tuzen ◽  
Nasrullah Shah ◽  
...  

AbstractIn this study, an extremely effective electromembrane extraction (EME) method was developed for the selective extraction of Cu(II) followed by Red-Green-Blue (RGB) detection. The effective parameters optimized for the extraction efficiency of EME include applied voltage, extraction time, supported liquid membrane (SLM) composition, pH of acceptor/donor phases, and stirring rate. Under optimized conditions, Cu(II) was extracted from a 3 mL aqueous donor phase to 8 µL of 100 mM HCl acceptor solution through 1-octanol SLM using an applied voltage of 50 V for 15 min. The proposed method provides a working range of 0.1–0.75 µg·mL−1 with 0.03 µg·mL−1 limit for detection. Finally, the developed technique was applied to different environmental water samples for monitoring environmental pollution. Obtained relative recoveries were within the range of 93–106%. The relative standard deviation (RSD) and enhancement factor (EF) were found to be ≤4.8% and 100 respectively. We hope that this method can be introduced for quantitative determination of Cu(II) as a fast, simple, portable, inexpensive, effective, and precise procedure.


2015 ◽  
Vol 853 ◽  
pp. 328-334 ◽  
Author(s):  
Chuixiu Huang ◽  
Astrid Gjelstad ◽  
Stig Pedersen-Bjergaard

Talanta ◽  
2019 ◽  
Vol 194 ◽  
pp. 298-307 ◽  
Author(s):  
Shahram Seidi ◽  
Mirsina Hashemi Ranjbar ◽  
Mahroo Baharfar ◽  
Maryam Shanehsaz ◽  
Mohammad Tajik

Sign in / Sign up

Export Citation Format

Share Document