Field Measurements and Determination of Electric Motor Efficiency*

Author(s):  
Albert Thumann ◽  
Harry Franz
Water ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1131
Author(s):  
Soonkie Nam ◽  
Marte Gutierrez ◽  
Panayiotis Diplas ◽  
John Petrie

This paper critically compares the use of laboratory tests against in situ tests combined with numerical seepage modeling to determine the hydraulic conductivity of natural soil deposits. Laboratory determination of hydraulic conductivity used the constant head permeability and oedometer tests on undisturbed Shelby tube and block soil samples. The auger hole method and Guelph permeameter tests were performed in the field. Groundwater table elevations in natural soil deposits with different hydraulic conductivity values were predicted using finite element seepage modeling and compared with field measurements to assess the various test results. Hydraulic conductivity values obtained by the auger hole method provide predictions that best match the groundwater table’s observed location at the field site. This observation indicates that hydraulic conductivity determined by the in situ test represents the actual conditions in the field better than that determined in a laboratory setting. The differences between the laboratory and in situ hydraulic conductivity values can be attributed to factors such as sample disturbance, soil anisotropy, fissures and cracks, and soil structure in addition to the conceptual and procedural differences in testing methods and effects of sample size.


2011 ◽  
Author(s):  
Alexandre Vauselle ◽  
Philippe Maillot ◽  
Gaëlle Georges ◽  
Carole Deumié ◽  
David G. Seiler ◽  
...  
Keyword(s):  

Author(s):  
Lucinda Smart ◽  
Richard McNealy ◽  
Harvey Haines

In-Line Inspection (ILI) is used to prioritize metal loss conditions based on predicted failure pressure in accordance with methods prescribed in industry standards such as ASME B31G-2009. Corrosion may occur in multiple areas of metal loss that interact and may result in a lower failure pressure than if flaws were analyzed separately. The B31G standard recommends a flaw interaction criterion for ILI metal loss predictions within a longitudinal and circumferential spacing of 3 times wall thickness, but cautions that methods employed for clustering of ILI anomalies should be validated with results from direct measurements in the ditch. Recent advances in non-destructive examination (NDE) and data correlation software have enabled reliable comparisons of ILI burst pressure predictions with the results from in-ditch examination. Data correlation using pattern matching algorithms allows the consideration of detection and reporting thresholds for both ILI and field measurements, and determination of error in the calculated failure pressure prediction attributable to the flaw interaction criterion. This paper presents a case study of magnetic flux leakage ILI failure pressure predictions compared with field results obtained during excavations. The effect of interaction criterion on calculated failure pressure and the probability of an ILI measurement underestimating failure pressure have been studied. We concluded a reason failure pressure specifications do not exist for ILI measurements is because of the variety of possible interaction criteria and data thresholds that can be employed, and demonstrate herein a method for their validation.


Gefahrstoffe ◽  
2019 ◽  
Vol 79 (10) ◽  
pp. 378-384
Author(s):  
C. Sun ◽  
C. Thelen ◽  
I. Sancho Sanz ◽  
A. Wittmann

The efficacy of a respirator under real workplace conditions is presented by its workplace protection factor (WPF). The aim of this study was to assess a portable measuring system for the determination of WPF for particulate filtering facepiece respirators. WPFs of CE-marked FFP2 and FFP3 filtering facepiece respirators were measured as a pilot test conducted at two workplaces: an inter-company training facility and a paper mill, with a total of seven test subjects. Each subject was quantitatively fit tested prior to the field measurements. Two TSI PortaCount instruments measured the particle concentrations simultaneously and continuously inside and outside the respirator for 15 min, with three repetitions. The results of the fit test (overall fit factor) ranged from 22 to 199. Individual WPF results ranged from 16 to 568 for FFP2 respirators, and from 13 to 232 for FFP3 respirators. The geometric means (GM) of the WPF were 135 with a 5th percentile value of 37 (FFP2), and 47 with a 5th percentile value of 12 (FFP3). This pilot test provides a new method of evaluating the workplace performance of filtering facepiece respirators.


2011 ◽  
Vol 2 (2) ◽  
pp. 39-47 ◽  
Author(s):  
Pui Tau Shien ◽  
Seneviratne H.N. ◽  
Dygku Salma Awg Ismail

Fibrous peat is an undrained peat that usually possesses very high moisture content. However, not all experimental procedures are applicable for determination of moisture content of fibrous peat. This research is aimed at examining the determination of insitu moisture content of fibrous peat using field measurements. The peat soil samples were collected at shallow depths from Asajaya at Kota Samarahan and Taman Kopodims at Matang , Kuching Sarawak by using peat auger. The laboratory tests such as determination of moisture content, fiber content, particle density and ash content were conducted on the collected samples in order to establish relationships between the parameters. Undisturbed peat samples from Matang were subjected to falling head permeability test to determine the saturated permeability. The saturated sample were then allowed to drain freely to simulate the moisture loss possible during sampling when samples were brought out of boreholes. The test results showed that moisture content varies according to the drying temperature and position of the soil sample (top, middle and bottom) during sampling. Comparing samples from both locations, peat soil from Kota Samarahan possessed higher moisture content. The saturated permeability of peat sample was in the range of 2.62 – 3.05 cm/s. The free draining trial showed that moisture loss during sampling significantly influence the moisture content measurement. The variation in value of moisture content for fibrous peat may occurs due to several factors such as existing ground water table, sampling method by boring, existing standard test procedure which is not suitable for peat soils requirement and also because of the physical properties which varied according to depth of soil.


2016 ◽  
Vol 5 (2) ◽  
pp. 281-288 ◽  
Author(s):  
Panagiotis P. Zacharias ◽  
Elpida G. Chatzineofytou ◽  
Sotirios T. Spantideas ◽  
Christos N. Capsalis

Abstract. In the present work, the determination of the magnetic behavior of localized magnetic sources from near-field measurements is examined. The distance power law of the magnetic field fall-off is used in various cases to accurately predict the magnetic signature of an equipment under test (EUT) consisting of multiple alternating current (AC) magnetic sources. Therefore, parameters concerning the location of the observation points (magnetometers) are studied towards this scope. The results clearly show that these parameters are independent of the EUT's size and layout. Additionally, the techniques developed in the present study enable the placing of the magnetometers close to the EUT, thus achieving high signal-to-noise ratio (SNR). Finally, the proposed method is verified by real measurements, using a mobile phone as an EUT.


Sign in / Sign up

Export Citation Format

Share Document