Structural surface assessment of ship structures intended for robotic inspection applications

2021 ◽  
pp. 563-569
Author(s):  
F.M. Shah ◽  
T. Gaggero ◽  
M. Gaiotti ◽  
L. Ivaldi ◽  
C.M. Rizzo
Coatings ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 928
Author(s):  
Sanja Mahović Poljaček ◽  
Tamara Tomašegović ◽  
Mirjam Leskovšek ◽  
Urška Stanković Elesini

In the present research, the properties of ultraviolet (UV) visible (daylight invisible) fluorescent coatings modified by the addition of SiO2 and TiO2 nanoparticles were studied. Structural, surface, and mechanical properties and changes in the coatings caused by accelerated ageing were analyzed. The results showed that the addition of nanoparticles caused the changes in unaged and aged printed coatings. Reflectance measurements of modified coatings showed that addition of TiO2 nanoparticles improved the visual effect of the unaged coatings. Furthermore, results have shown that the addition of SiO2 did not diminish the reflectance of the modified coatings after ageing. The results of roughness measurements showed that the addition of SiO2 decreased roughness after the ageing process, probably due to the degradation process indicated by Attenuated Total Reflection Fourier Transform Infrared (ATR-FTIR) spectroscopy. The roughness of the coatings with TiO2 nanoparticles was increased after the ageing on the samples with higher concentrations of TiO2 due to the agglomerates of plastisol formed on the surface of the coatings, visible in SEM images. Surface analysis of coatings showed that TiO2 caused an increase in the polarity of the surface coatings. Results of the bending stiffness showed that the addition of the nanoparticles to the coating, especially of SiO2, significantly improved the bending stiffness of the unaged samples.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Dai Woo Kim ◽  
Jonghoon Shin ◽  
Chang Kyu Lee ◽  
Myungjin Kim ◽  
Sohyeon Lee ◽  
...  

AbstractGiven that nonadherence is related to subject characteristics and drug tolerance and preserved eye drops tend to be more intolerable than preservative-free ones, we conducted a phase 4, parallel-grouped, investigator-blind, active-control, randomized, multicenter study. A total of 51 patients with intraocular pressure (IOP) ≥ 15 mmHg diagnosed with open-angle glaucoma or ocular hypertension were randomly assigned to the preserved latanoprost group (n = 26) and the preservative-free latanoprost group (n = 25). The efficacy variables were corneal/conjunctival staining grade, Ocular Surface Disease Index (OSDI), adherence at 12 weeks after the first administration; corneal/conjunctival staining grade at 4 weeks; and IOP, tear break-up time (TBUT), and hyperemia score at 4 and 12 weeks. The safety variables included visual acuity and drug tolerance questionnaire results. There was no statistically significant difference in corneal/conjunctival staining grade, OSDI, or TBUT between the groups at 4 and 12 weeks. However, the adherence rate was higher and the hyperemia score was lower in the preservative-free group than in the preserved group. The severity and duration of stinging/burning sensation were lower in the preservative-free group than in the preserved group. Overall, preservative-free latanoprost showed better ocular tolerance assessed by hyperemia scores and stinging/burning symptoms following higher adherence than preserved latanoprost.


2019 ◽  
Vol 51 (04) ◽  
pp. 240-248
Author(s):  
Lucas Etzel ◽  
Konstantin Christoph Koban ◽  
Zhouxiao Li ◽  
Konstantin Frank ◽  
Riccardo Enzo Giunta ◽  
...  

Zusammenfassung Hintergrund Dreidimensionale (3D) Oberflächenaufnahmen haben sich als objektiver Mehrwert in der Planung und Dokumentation unterschiedlicher plastisch chirurgischer Eingriffe erwiesen. Obwohl Oberflächen- und Volumenanalysen für einzelne Bereiche wie der Brust und des Gesichts im klinischen Alltag eingesetzt werden, war es bislang nicht ausreichend möglich, Auswirkungen auf die gesamte Körperoberfläche zu erfassen und zu quantifizieren. Ziel dieser Studie war die Implementierung von 360° Ganzkörperscans zur zukünftigen Therapie-Evaluierung beim Lipödem. Patienten, Material und Methoden Drei unterschiedliche 3D Oberflächenscanner (Eva, Thor und Sense) wurden am Probanden hinsichtlich ihrer Reproduzierbarkeit und Präzision für 360° Aufnahmen evaluiert. Unter einem standardisierten Setting bestehend aus einem automatischen Drehteller und definierten Posen wurden axiale Umfangsmessungen und schichtweise Volumina bestimmt. Statistische und klinische relevante Abweichungen wurden untersucht. Ergebnisse Ein standardisierter 360° Scan Ablauf wurde implementiert. Die Reproduzierbarkeit aller Scanner war zufriedenstellend (p > 0,05). Es zeigten sich vergleichbare axiale Umfangsmessungen und Volumina für den Eva und Thor Scanner (p > 0,05). Der Sense Scanner erreichte eine ausreichende Messgenauigkeit im Thoraxbereich, jedoch signifikante Abweichungen an der unteren Extremität (p < 0,05). Die Datenauswertung konnte auf ausgewählte klinische Beispiele übertragen werden. Schlussfolgerung Es konnte erfolgreich eine 360° Oberflächenaufnahmetechnik und Analyse in der Plastischen Chirurgie eingeführt werden. Zwei der getesteten Geräte ermöglichen objektive Umfangs- und Volumenmessungen am gesamten Körper. Das dritte Gerät, der günstige Sense Scanner, ermöglichte zwar 360° Aufnahmen, jedoch war dessen Präzision nicht für alle Bereiche ausreichend. In Zukunft könnten somit die Auswirkungen unterschiedlicher Therapien an der gesamten Körperoberfläche evaluiert werden.


2021 ◽  
pp. 103037
Author(s):  
Angelo Mario Böhm ◽  
Rüdiger Ulrich Franz von Bock und Polach ◽  
Hauke Herrnring ◽  
Sören Ehlers

Sign in / Sign up

Export Citation Format

Share Document