Counter-flow spiral heat exchanger – Spirex

2007 ◽  
2018 ◽  
Author(s):  
Bharath P ◽  
Doddamani Hithaish ◽  
Saravanan Venkatesh ◽  
C K Umesh

2019 ◽  
Vol 5 ◽  
pp. 34-40 ◽  
Author(s):  
M. Sridharan ◽  
R. Devi ◽  
C.S. Dharshini ◽  
M. Bhavadarani

2019 ◽  
Vol 11 (4) ◽  
pp. 426-445
Author(s):  
Ahmed A. Ali ◽  
Mushtaq I. Hasan ◽  
Ghassan Adnan

In this paper the effect of surface roughness on the performance of counter flow microchannel heat exchanger has been numerically investigated. The studied Microchannel heat exchanger is a square shape and made of aluminum as substrate material with different values of hydraulic diameters (20, 50, 110, 150 ) μm. The working fluid used is water  at constant properties. Roughness- viscosity model has been used to study the roughness effect with 0.14 ratio of roughness to hydraulic diameter.  The results obtained indicate that pressure drop of (CFMCHX) increased with increasing surface roughness and decrease hydraulic diameter also the results showed that there is a slight increasing in thermal performance with increasing the surface roughness.


Author(s):  
Nyoman Arya Wigraha

Pengaruh turbulator Louvered strips terhadap laju perpindahan kalor dan faktor gesekan aliran turbulen pada double tube heat exchanger dapat memecah (partitioning) dan mengganggu (blockage) pola streamline dari fluida yang mengalir ke saluran pipa dalam (inner tube) sehingga mengakumulasi aliran turbulensi dan meningkatkan laju perpindahan kalor dalam pipa. Louvered strips memiliki variasi sudut serang (q = 15°, 25°, 30°) yang terpasang ditengah-tengah pipa bagian dalam dan searah aliran fluida masuk. Laju aliran fluida (air) panas di bagian pipa dalam diteliti dengan interval 400 lt/jam sampai 900 lt/jam dan laju aliran air dingin di bagian pipa luar konstan 900 lt/jam. Data hasil pengujian dari masing – masing sudut serang turbulator ini dibandingkan data tanpa turbulator (plain tube),  secara keseluruhan terjadi peningkatan laju perpindahan kalor sebesar 26 % sampai 58 % dari pada tanpa turbulator serta menghasilkan faktor gesekan dari 25 % sampai 40 %. Dengan performance ratio rata –rata tertinggi pada turbulator dengan sudut 30O sebesar 0,948.   Kata kunci:  Louvered strips, Heat Exchanger, Counter flow, turbulensi, faktor gesekan, turbulator, efektifitas


2011 ◽  
Vol 8 (2) ◽  
Author(s):  
Nyoman Arya Wigraha

Pengaruh turbulator Louvered strips terhadap laju perpindahan kalor dan faktor gesekan aliran turbulen pada double tube heat exchanger dapat memecah (partitioning) dan mengganggu (blockage) pola streamline dari fluida yang mengalir ke saluran pipa dalam (inner tube) sehingga mengakumulasi aliran turbulensi dan meningkatkan laju perpindahan kalor dalam pipa. Louvered strips memiliki variasi sudut serang (q = 15°, 25°, 30°) yang terpasang ditengah-tengah pipa bagian dalam dan searah aliran fluida masuk. Laju aliran fluida (air) panas di bagian pipa dalam diteliti dengan interval 400 lt/jam sampai 900 lt/jam dan laju aliran air dingin di bagian pipa luar konstan 900 lt/jam. Data hasil pengujian dari masing – masing sudut serang turbulator ini dibandingkan data tanpa turbulator (plain tube),  secara keseluruhan terjadi peningkatan laju perpindahan kalor sebesar 26 % sampai 58 % dari pada tanpa turbulator serta menghasilkan faktor gesekan dari 25 % sampai 40 %. Dengan performance ratio rata –rata tertinggi pada turbulator dengan sudut 30O sebesar 0,948.   Kata kunci:  Louvered strips, Heat Exchanger, Counter flow, turbulensi, faktor gesekan, turbulator, efektifitas


Sign in / Sign up

Export Citation Format

Share Document