- Impedance Spectroscopy on Carbon-Based Materials for Biological Application

2016 ◽  
pp. 150-209
2014 ◽  
Vol 131 ◽  
pp. 168-173 ◽  
Author(s):  
Omar Samuel Mendoza-Hernandez ◽  
Hiroaki Ishikawa ◽  
Yuuki Nishikawa ◽  
Yuki Maruyama ◽  
Yoshitsugu Sone ◽  
...  

Author(s):  
B. K. Kirchoff ◽  
L.F. Allard ◽  
W.C. Bigelow

In attempting to use the SEM to investigate the transition from the vegetative to the floral state in oat (Avena sativa L.) it was discovered that the procedures of fixation and critical point drying (CPD), and fresh tissue examination of the specimens gave unsatisfactory results. In most cases, by using these techniques, cells of the tissue were collapsed or otherwise visibly distorted. Figure 1 shows the results of fixation with 4.5% formaldehyde-gluteraldehyde followed by CPD. Almost all cellular detail has been obscured by the resulting shrinkage distortions. The larger cracks seen on the left of the picture may be due to dissection damage, rather than CPD. The results of observation of fresh tissue are seen in Fig. 2. Although there is a substantial improvement over CPD, some cell collapse still occurs.Due to these difficulties, it was decided to experiment with cold stage techniques. The specimens to be observed were dissected out and attached to the sample stub using a carbon based conductive paint in acetone.


Author(s):  
Toichiro Kuwabara

Although scanning electron microscopy has a great potential in biological application, there are certain limitations in visualization of the biological structure. Satisfactory techniques to demonstrate natural surfaces of the tissue and the cell have been reported by several investigators. However, it is commonly found that the surface cell membrane is covered with a minute amount of mucin, secretory substance or tissue fluid as physiological, pathological or artefactual condition. These substances give a false surface appearance, especially when the tissue is fixed with strong fixatives. It seems important to remove these coating substances from the surface of the cell for demonstration of the true structure.


2020 ◽  
Author(s):  
Idoia Hita ◽  
Tomas Cordero-Lanzac ◽  
Francisco J. Garcia-Mateos ◽  
Jose Rodriguez-Mirasol ◽  
Tomas Cordero ◽  
...  

2020 ◽  
Author(s):  
Idoia Hita ◽  
Tomas Cordero-Lanzac ◽  
Francisco J. Garcia-Mateos ◽  
Jose Rodriguez-Mirasol ◽  
Tomas Cordero ◽  
...  

2015 ◽  
Vol 12 (2) ◽  
pp. 13
Author(s):  
Muhamad Faridz Osman ◽  
Karimah Kassim

The coordination complexes of Co(II) and Zn(II) with Schiff bases derived from o-phenylenediamine and substituted 2-hydroxybenzaldehyde were prepared All compounds were characterized by Fourier transform infrared (FTIR) spectroscopy and Nuclear magnetic resonance (NMR) spectroscopy elemental analyzers. They were analyzed using impedance spectroscopy in the frequency range of 100Hz-1 MHz. LI and L2 showed higher conductivity compared to their metal complexes, which had values of 1.3 7 x 10-7 and 6.13 x 10-8 S/cm respectively. 


2020 ◽  
Vol 4 (3) ◽  
pp. 150-155 ◽  
Author(s):  
Md. Mehadi Hasan Sohag ◽  
Olivier Nicoud ◽  
Racha Amine ◽  
Abir Khalil-Mgharbel ◽  
Jean-Pierre Alcaraz ◽  
...  

AbstractThe goal of this study was to determine whether the Tethapod system, which was designed to determine the impedance properties of lipid bilayers, could be used for cell culture in order to utilise micro-impedance spectroscopy to examine further biological applications. To that purpose we have used normal epithelial cells from kidney (RPTEC) and a kidney cancer cell model (786-O). We demonstrate that the Tethapod system is compatible with the culture of 10,000 cells seeded to grow on a small area gold measurement electrode for several days without affecting the cell viability. Furthermore, the range of frequencies for EIS measurements were tuned to examine easily the characteristics of the cell monolayer. We demonstrate significant differences in the paracellular resistance pathway between normal and cancer kidney epithelial cells. Thus, we conclude that this device has advantages for the study of cultured cells that include (i) the configuration of measurement and reference electrodes across a microfluidic channel, and (ii) the small surface area of 6 parallel measurement electrodes (2.1 mm2) integrated in a microfluidic system. These characteristics might improve micro-impedance spectroscopy measurement techniques to provide a simple tool for further studies in the field of the patho-physiology of biological barriers.


Sign in / Sign up

Export Citation Format

Share Document