scholarly journals Positron emission tomography PET/CT harmonisation study of different clinical PET/CT scanners using commercially available software

BJR|Open ◽  
2020 ◽  
Vol 2 (1) ◽  
pp. 20190035
Author(s):  
Gerry Lowe ◽  
Bruce Spottiswoode ◽  
Jerome Declerck ◽  
Keith Sullivan ◽  
Mhd Saeed Sharif ◽  
...  

Objectives: Harmonisation is the process whereby standardised uptake values from different scanners can be made comparable. This PET/CT pilot study aimed to evaluate the effectiveness of harmonisation of a modern scanner with image reconstruction incorporating resolution recovery (RR) with another vendor older scanner operated in two-dimensional (2D) mode, and for both against a European standard (EARL). The vendor-proprietary software EQ•PET was used, which achieves harmonisation with a Gaussian smoothing. A substudy investigated effect of RR on harmonisation. Methods: Phantom studies on each scanner were performed to optimise the smoothing parameters required to achieve successful harmonisation. 80 patients were retrospectively selected; half were imaged on each scanner. As proof of principle, a cohort of 10 patients was selected from the modern scanner subjects to study the effects of RR on harmonisation. Results: Before harmonisation, the modern scanner without RR adhered to EARL specification. Using the phantom data, filters were derived for optimal harmonisation between scanners and with and without RR as applicable, to the EARL standard. The 80-patient cohort did not reveal any statistically significant differences. In the 10-patient cohort SUVmax for RR > no RR irrespective of harmonisation but differences lacked statistical significance (one-way ANOVA F(3.36) = 0.37, p = 0.78). Bland-Altman analysis showed that harmonisation reduced the SUVmax ratio between RR and no RR to 1.07 (95% CI 0.96–1.18) with no outliers. Conclusions: EQ•PET successfully enabled harmonisation between modern and older scanners and against the EARL standard. Harmonisation reduces SUVmax and dependence on the use of RR in the modern scanner. Advances in knowledge: EQ•PET is feasible to harmonise different PET/CT scanners and reduces the effect of RR on SUVmax.

Author(s):  
Martina Broecker-Preuss ◽  
Nina Becher-Boveleth ◽  
Stefan P. Müller ◽  
Andreas Hüttmann ◽  
Christine Hanoun ◽  
...  

Abstract Background [18F]Fluoro-deoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) is the standard imaging procedure in diffuse large B-cell lymphoma (DLBCL). Disease presentation, FDG-PET/CT performance, and outcome may be influenced by germline single nucleotide polymorphisms (SNP) in genes regulating glucose uptake. Methods Clinical variables, FDG-PET findings, and outcome were analysed in relation to SNPs in 342 DLBCL patients participating in the ‘Positron Emission Tomography-Guided Therapy of Aggressive Non-Hodgkin Lymphomas’ (PETAL) trial. Genes analysed included SLC2A1 (SNPs rs1385129, referred to as HaeIII; rs710218, HpyCH4V; rs841853, XbaI), VEGFA (rs3025039), HIF1A (rs11549465, P582S; rs11549467, A588T), and APEX1 (rs1130409, D148E). Statistical significance was assumed at p ≤ 0.05. Results The SLC2A1 HaeIII and HpyCH4V SNPs were tightly linked and statistically significantly associated with baseline maximum standardized uptake value (SUVmax) and Ann Arbor stage, with slightly lower SUVmax (HaeIII, median 18.9, interquartile range [IQR] 11.5–26.6, versus 21.6, IQR 14.4–29.7; p = 0.019) and more frequent stage IV disease (HaeIII, 44.5% versus 30.8%; p = 0.011) in minor allele carriers. As previously reported for lung cancer, the association was dependent upon the coexistent APEX1 D148E genotype. The HIF1A A588T SNP was associated with total metabolic tumour volume (TMTV) and time-to-progression, with significantly lower TMTV (median 16 cm3, IQR 7–210, versus 146 cm3, IQR 34–510; p = 0.034) and longer time-to-progression in minor allele carriers (log-rank p = 0.094). Time-to-progression was also associated with the SLC2A1 XbaI and APEX1 D148E SNPs, with shorter time-to-progression in homozygous and heterozygous SLC2A1 XbaI (HR 1.456; CI 0.930–2.280; p = 0.099) and homozygous APEX1 D148E minor allele carriers (HR 1.6; CI 1.005–2.545; p = 0.046). In multivariable analyses including SNPs, International Prognostic Index factors, sex, and B symptoms, HIF1A A588T, SLC2A1 XbaI, and APEX1 D148E retained statistical significance for time-to-progression, and SLC2A1 XbaI was also significantly associated with overall survival. Conclusions Common SNPs in genes regulating glucose uptake may impact SUVmax, tumour distribution, tumour volume, and outcome in DLBCL. The effects on SUVmax are of low magnitude and appear clinically negligible. The results are consistent with findings in other types of cancer. They need to be confirmed in an independent DLBCL population of sufficient size. Trial registration Trial registration: ClinicalTrials.gov NCT00554164; EudraCT 2006-001641-33. Registration date November 5, 2007, https://www.clinicaltrials.gov/ct2/show/NCT00554164


2018 ◽  
Vol 38 (3) ◽  
Author(s):  
Chen Tian ◽  
Lu Wang ◽  
Ling Wu ◽  
Lei Zhu ◽  
Wengui Xu ◽  
...  

Multiple myeloma (MM) is a hematological neoplasm which results in diffuse or focal bone infiltration and extramedullary lesions. It’s reported that infiltration of organs by plasma cells indicated worse prognosis, but the prognosis of patients with bone-related extramedullary disease (bEMD) is still unknown. One hundred and fourteen newly diagnosed MM patients were retrospectively reviewed. Results showed that the clinical features, overall survival (OS), and progression-free survival (PFS) of patients with and without bEMD had no statistical significance. Rib (46.1%) and vertebrae (17.9%) are common sites bEMD involved. Patients with diffuse bEMD had worse prognosis compared with patients with focal bEMD. Bisphosphonates played an important role in prolonging the survival of patients with bEMD. Positron emission tomography (PET)/computed tomography (CT) is sensitive in discovering bEMD than whole body low dose CT suggesting PET/CT to be a promising technique for initial staging. High β2-microglobulin and low albumin indicated shorter survival in patients with bEMD.


2021 ◽  
Vol 22 (22) ◽  
pp. 12591
Author(s):  
Tomasz Jan Kolanowski ◽  
Weronika Wargocka-Matuszewska ◽  
Agnieszka Zimna ◽  
Lukasz Cheda ◽  
Joanna Zyprych-Walczak ◽  
...  

Cardiovascular diseases (CVD), with myocardial infarction (MI) being one of the crucial components, wreak havoc in developed countries. Advanced imaging technologies are required to obtain quick and widely available diagnostic data. This paper describes a multimodal approach to in vivo perfusion imaging using the novel SYN1 tracer based on the fluorine-18 isotope. The NOD-SCID mice were injected intravenously with SYN1 or [18F] fluorodeoxyglucose ([18F]-FDG) radiotracers after induction of the MI. In all studies, the positron emission tomography–computed tomography (PET/CT) technique was used. To obtain hemodynamic data, mice were subjected to magnetic resonance imaging (MRI). Finally, the biodistribution of the SYN1 compound was performed using Wistar rat model. SYN1 showed normal accumulation in mouse and rat hearts, and MI hearts correctly indicated impaired cardiac segments when compared to [18F]-FDG uptake. In vivo PET/CT and MRI studies showed statistical convergence in terms of the size of the necrotic zone and cardiac function. This was further supported with RNAseq molecular analyses to correlate the candidate function genes’ expression, with Serpinb1c, Tnc and Nupr1, with Trem2 and Aldolase B functional correlations showing statistical significance in both SYN1 and [18F]-FDG. Our manuscript presents a new fluorine-18-based perfusion radiotracer for PET/CT imaging that may have importance in clinical applications. Future research should focus on confirmation of the data elucidated here to prepare SYN1 for first-in-human trials.


2018 ◽  
Vol 60 (1) ◽  
pp. 78-84
Author(s):  
Wayne B Cohen-Levy ◽  
Juan Pretell-Mazzini ◽  
Adam D Singer ◽  
Ty Subhawong ◽  
Dylan N Greif ◽  
...  

Background Positron emission tomography/computed tomography (PET/CT) is a useful imaging adjunct in patients with sarcoma. Intra-articular and peri-articular 18F-fluoro-2-deoxy-D-glucose (FDG) avid lesions are often discovered incidentally. Purpose To describe the etiology, appearance, and standardized uptake values (SUV) of incidentally detected FDG avid intra-articular and peri-articular foci in patients with sarcoma. Material and Methods The institutional sarcoma database between November 2011 and November 2016 was retrospectively reviewed. Patients were included if a PET/CT scan was performed and an FDG avid intra-articular or peri-articular focus was found that was distinct from the primary sarcoma. Results The majority of FDG avid foci represented benign, non-physiologic conditions such as osteoarthritis, enthesopathy, bursitis, and post-surgical changes. Six patients each had radiographic features consistent with tenosynovial giant cell tumor (TSGCT) and metastatic disease, respectively. Lower SUV, bilateral findings, and the absence of metastatic disease elsewhere were associated with benign etiologies. There was a statistically significant difference between the mean SUV measured in patients with TSGCT and those with benign, non-physiologic conditions ( P < 0.001). The difference between the benign, non-physiologic cohort and the cohort with widespread metastatic disease did not reach statistical significance ( P = 0.07). Conclusions In patients with soft-tissue or osseous sarcomas, isolated FDG avid intra-articular or peri-articular foci without additional metastatic lesions likely represent benign processes. Isolated intra-articular or peri-articular foci with significantly elevated SUV measurements were favored to represent TSGCT in this series.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Iva Speck ◽  
Valentin Rottmayer ◽  
Konstantin Wiebe ◽  
Antje Aschendorff ◽  
Johannes Thurow ◽  
...  

AbstractPositron emission tomography (PET) has been successfully used to investigate central nervous processes, including the central auditory pathway. Unlike early water-cooled PET-scanners, novel PET/CT scanners employ air cooling and include a CT system, both of which result in higher background noise levels. In the present study, we describe the background noise generated by two state-of-the-art air-cooled PET/CT scanners. We measured speech recognition in background noise: recorded PET noise and a speech-shaped noise applied in clinical routine to subjects with normal hearing. Background noise produced by air-cooled PET/CT is considerable: 75.1 dB SPL (64.5 dB(A)) for the Philips Gemini TF64 and 76.9 dB SPL (68.4 dB(A)) for the Philips Vereos PET/CT (Philips Healthcare, The Netherlands). Subjects with normal hearing exhibited better speech recognition in recorded PET background noise compared with clinically applied speech-shaped noise. Speech recognition in both background noises correlated significantly. Background noise generated by PET/CT scanners should be considered when PET is used for the investigation of the central auditory pathway. Speech in PET noise is better than in speech-shaped noise because of the minor masking effect of the background noise of the PET/CT.


2005 ◽  
Vol 44 (S 01) ◽  
pp. S46-S50 ◽  
Author(s):  
M. Dawood ◽  
N. Lang ◽  
F. Büther ◽  
M. Schäfers ◽  
O. Schober ◽  
...  

Summary:Motion in PET/CT leads to artifacts in the reconstructed PET images due to the different acquisition times of positron emission tomography and computed tomography. The effect of motion on cardiac PET/CT images is evaluated in this study and a novel approach for motion correction based on optical flow methods is outlined. The Lukas-Kanade optical flow algorithm is used to calculate the motion vector field on both simulated phantom data as well as measured human PET data. The motion of the myocardium is corrected by non-linear registration techniques and results are compared to uncorrected images.


2011 ◽  
Vol 14 (5) ◽  
pp. 283 ◽  
Author(s):  
Andre Plass ◽  
Maximilian Y. Emmert ◽  
Oliver Gaemperli ◽  
Hatem Alkadhi ◽  
Philipp Kaufmann ◽  
...  

<p><b>Background:</b> We evaluated how comprehensive assessment of coronary artery lesions and their hemodynamic relevance by means of hybrid positron emission tomography (PET) and computed tomography (CT) imaging would affect decision-making in coronary artery bypass surgery (CABG), compared with using invasive coronary angiography (ICA) alone.</p><p><b>Methods:</b> After undergoing ICA, 27 patients (21 men and 6 women; mean SD age, 66 � 10 years) planned for cardiac surgery were scheduled for myocardial perfusion stress/rest evaluation with [13N]ammonia PET and CT coronary angiography. Only ICA was available to the surgeon. Postoperatively, the performed CABG was compared with the hypothetical strategy based on hybrid PET/CT findings (regional coronary flow reserve [CFR], myocardial perfusion defects). Procedures included CABG (n = 18) alone, CABG combined with valve replacement (n = 6), and CABG combined with isolated valve replacement (n = 3). A total of 56 bypass grafts (28 venous and 28 arterial) and 66 distal anastomoses were placed.</p><p><b>Results:</b> CT evaluation showed 93% concordance (66/71) with ICA regarding significant stenoses, with sensitivity, specificity, positive predictive value, and negative predictive value of 93.1%, 98.7%, 94.4%, and 98.4%, respectively. In the PET scan, 16 patients had 1 ischemic region, and 12 patients had 1 scar region, including 5 patients who presented with mixed conditions (scar and ischemia). One patient had a completely normal myocardium. Compared with the performed surgery, PET/CT fusion evaluation showed that of the performed anastomoses, 48% had documented ischemia (with a CFR <2 in 86%), 38% were nonischemic (although a CFR value <2 was found in 78%), and 14% had scar tissue (fixed perfusion defect).</p><p><b>Conclusions:</b> Although <50% of bypasses were placed to areas with myocardial ischemia, the CFR was low in the majority of nonischemic regions, a finding that may have important prognostic relevance. PET/CT fusion imaging could potentially influence planning for CABG and provide incremental prognostic information.</p>