scholarly journals On the explicit use of experimental images in high resolution cryo-EM refinement

F1000Research ◽  
2019 ◽  
Vol 8 ◽  
pp. 665
Author(s):  
Jacqueline Cherfils ◽  
Jorge Navaza

Single particle cryogenic electron microscopy (cryo-EM) is transforming structural biology by enabling the analysis of difficult macromolecular specimens, such as membrane proteins or large complexes with flexible elements, at near atomic resolution with an accuracy close to that of X-ray crystallography. As the technique continues to improve, it is important to assess and exploit its full potential to produce the most possible reliable atomic models. Here we propose to use the experimental images as the data for refinement and validation, instead of the reconstructed maps as currently used. This procedure, which is in spirit quite similar to that used in X-ray crystallography where the data include experimental phases, should contribute to improve the quality of the cryo-EM atomic models.

F1000Research ◽  
2019 ◽  
Vol 8 ◽  
pp. 665
Author(s):  
Jacqueline Cherfils ◽  
Jorge Navaza

Single particle cryogenic electron microscopy (cryo-EM) is transforming structural biology by enabling the analysis of difficult macromolecular specimens, such as membrane proteins or large complexes with flexible elements, at near atomic resolution with an accuracy close to that of X-ray crystallography. As the technique continues to improve, it is important to assess and exploit its full potential to produce the most possible reliable atomic models. Here we propose to use the experimental images as the data for refinement and validation, instead of the reconstructed maps as currently used. This procedure, which is in spirit quite similar to that used in X-ray crystallography where the data include experimental phases, should contribute to improve the quality of the models.


2016 ◽  
Vol 62 (3) ◽  
pp. 383-394
Author(s):  
Mariusz Czarnocki-Cieciura ◽  
Marcin Nowotny

For many years two techniques have dominated structural biology – X-ray crystallography and NMR spectroscopy. Traditional cryo-electron microscopy of biological macromolecules produced macromolecular reconstructions at resolution limited to 6–10 Å. Recent development of transmission electron microscopes, in particular the development of direct electron detectors, and continuous improvements in the available software, have led to the “resolution revolution” in cryo-EM. It is now possible to routinely obtain near-atomic-resolution 3D maps of intact biological macromolecules as small as ~100 kDa. Thus, cryo-EM is now becoming the method of choice for structural analysis of many complex assemblies that are unsuitable for structure determination by other methods.


F1000Research ◽  
2020 ◽  
Vol 9 ◽  
pp. 667
Author(s):  
Michael C. Thompson ◽  
Todd O. Yeates ◽  
Jose A. Rodriguez

Recent technical advances have dramatically increased the power and scope of structural biology. New developments in high-resolution cryo-electron microscopy, serial X-ray crystallography, and electron diffraction have been especially transformative. Here we highlight some of the latest advances and current challenges at the frontiers of atomic resolution methods for elucidating the structures and dynamical properties of macromolecules and their complexes.


Author(s):  
Robert A. Grant ◽  
Laura L. Degn ◽  
Wah Chiu ◽  
John Robinson

Proteolytic digestion of the immunoglobulin IgG with papain cleaves the molecule into an antigen binding fragment, Fab, and a compliment binding fragment, Fc. Structures of intact immunoglobulin, Fab and Fc from various sources have been solved by X-ray crystallography. Rabbit Fc can be crystallized as thin platelets suitable for high resolution electron microscopy. The structure of rabbit Fc can be expected to be similar to the known structure of human Fc, making it an ideal specimen for comparing the X-ray and electron crystallographic techniques and for the application of the molecular replacement technique to electron crystallography. Thin protein crystals embedded in ice diffract to high resolution. A low resolution image of a frozen, hydrated crystal can be expected to have a better contrast than a glucose embedded crystal due to the larger density difference between protein and ice compared to protein and glucose. For these reasons we are using an ice embedding technique to prepare the rabbit Fc crystals for molecular structure analysis by electron microscopy.


Crystals ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. 580
Author(s):  
Victor R.A. Dubach ◽  
Albert Guskov

X-ray crystallography and single-particle analysis cryogenic electron microscopy are essential techniques for uncovering the three-dimensional structures of biological macromolecules. Both techniques rely on the Fourier transform to calculate experimental maps. However, one of the crucial parameters, resolution, is rather broadly defined. Here, the methods to determine the resolution in X-ray crystallography and single-particle analysis are summarized. In X-ray crystallography, it is becoming increasingly more common to include reflections discarded previously by traditionally used standards, allowing for the inclusion of incomplete and anisotropic reflections into the refinement process. In general, the resolution is the smallest lattice spacing given by Bragg’s law for a particular set of X-ray diffraction intensities; however, typically the resolution is truncated by the user during the data processing based on certain parameters and later it is used during refinement. However, at which resolution to perform such a truncation is not always clear and this makes it very confusing for the novices entering the structural biology field. Furthermore, it is argued that the effective resolution should be also reported as it is a more descriptive measure accounting for anisotropy and incompleteness of the data. In single particle cryo-EM, the situation is not much better, as multiple ways exist to determine the resolution, such as Fourier shell correlation, spectral signal-to-noise ratio and the Fourier neighbor correlation. The most widely accepted is the Fourier shell correlation using a threshold of 0.143 to define the resolution (so-called “gold-standard”), although it is still debated whether this is the correct threshold. Besides, the resolution obtained from the Fourier shell correlation is an estimate of varying resolution across the density map. In reality, the interpretability of the map is more important than the numerical value of the resolution.


2014 ◽  
Vol 59 (3) ◽  
pp. 315-322 ◽  
Author(s):  
A. E. Blagov ◽  
A. L. Vasiliev ◽  
A. S. Golubeva ◽  
I. A. Ivanov ◽  
O. A. Kondratev ◽  
...  

2008 ◽  
Vol 1069 ◽  
Author(s):  
Hui Chen ◽  
Guan Wang ◽  
Michael Dudley ◽  
Zhou Xu ◽  
James. H. Edgar ◽  
...  

ABSTRACTA systematic study is presented of the heteroepitaxial growth of B12As2 on m-plane 15R-SiC. In contrast to previous studies of B12As2 on other substrates, including (100) Si, (110) Si, (111) Si and (0001) 6H-SiC, single crystalline and untwinned B12As2 was achieved on m-plane 15R-SiC. Observations of IBA on m-plane (1100)15R-SiC by synchrotron white beam x-ray topography (SWBXT) and high resolution transmission electron microscopy (HRTEM) confirm the good quality of the films on the 15R-SiC substrates. The growth mechanism of IBA on m-plane 15R-SiC is discussed. This work demonstrates that m-plane 15R-SiC is potentially a good substrate choice to grow high quality B12As2 epilayers.


Sign in / Sign up

Export Citation Format

Share Document