Inducible displacement of cemented tibial components ten years after total knee arthroplasty

2018 ◽  
Vol 100-B (2) ◽  
pp. 170-175 ◽  
Author(s):  
K. Lam Tin Cheung ◽  
B. A. Lanting ◽  
R. W. McCalden ◽  
X. Yuan ◽  
S. J. MacDonald ◽  
...  

Aims The aim of this study was to evaluate the long-term inducible displacement of cemented tibial components ten years after total knee arthroplasty (TKA). Patients and Methods A total of 15 patients from a previously reported prospective trial of fixation using radiostereometric analysis (RSA) were examined at a mean of 11 years (10 to 11) postoperatively. Longitudinal supine RSA examinations were acquired at one week, one year, and two years postoperatively and at final follow-up. Weight-bearing RSA examinations were also undertaken with the operated lower limb in neutral and in maximum internal rotation positions. Maximum total point motion (MTPM) was calculated for the longitudinal and inducible displacement examinations (supine versus standing, standing versus internal rotation, and supine versus standing with internal rotation). Results All patients showed some inducible displacement. Two patients with radiolucent lines had greater mean standing-supine MTPM displacement (1.35; sd 0.38) compared with the remaining patients (0.68; sd 0.36). These two patients also had a greater mean longitudinal MTPM at ten years (0.64; sd 0.50) compared with the remaining patients (0.39; sd 0.13 mm). Conclusion Small inducible displacements in well-fixed cemented tibial components were seen ten years postoperatively, of a similar magnitude to that which has been reported for well-fixed components one to two years postoperatively. Greater displacements were found in components with radiolucent lines. Cite this article: Bone Joint J 2018;100-B:170–5.

Author(s):  
Matthias Meyer ◽  
Tobias Renkawitz ◽  
Florian Völlner ◽  
Achim Benditz ◽  
Joachim Grifka ◽  
...  

Abstract Introduction Because of the ongoing discussion of imageless navigation in total knee arthroplasty (TKA), its advantages and disadvantages were evaluated in a large patient cohort. Methods This retrospective analysis included 2464 patients who had undergone TKA at a high-volume university arthroplasty center between 2012 and 2017. Navigated and conventional TKA were compared regarding postoperative mechanical axis, surgery duration, complication rates, one-year postoperative patient-reported outcome measures (PROMs) (WOMAC and EQ-5D indices), and responder rates as defined by the criteria of the Outcome Measures in Rheumatology and Osteoarthritis Research Society International consensus (OMERACT-OARSI). Results Both navigated (1.8 ± 1.6°) and conventional TKA (2.1 ± 1.6°, p = 0.002) enabled the exact reconstruction of mechanical axis. Surgery duration was six minutes longer for navigated TKA than for conventional TKA (p < 0.001). Complication rates were low in both groups with comparable frequencies: neurological deficits (p = 0.39), joint infection (p = 0.42 and thromboembolic events (p = 0.03). Periprosthetic fractures occurred more frequently during conventional TKA (p = 0.001). One-year PROMs showed excellent improvement in both groups. The WOMAC index was statistically higher for navigated TKA than for conventional TKA (74.7 ± 19.0 vs. 71.7 ± 20.7, p = 0.014), but the increase was not clinically relevant. Both groups had a similarly high EQ-5D index (0.23 ± 0.24 vs. 0.26 ± 0.25, p = 0.11) and responder rate (86.5% [256/296] vs. 85.9% [981/1142], p = 0.92). Conclusion Both methods enable accurate postoperative leg alignment with low complication rates and equally successful PROMs and responder rates one year postoperatively. Level of evidence III. Retrospective cohort study.


2021 ◽  
Vol 103-B (7) ◽  
pp. 1254-1260
Author(s):  
Lorenzo Calabro ◽  
Nick D. Clement ◽  
Deborah MacDonald ◽  
James T. Patton ◽  
Colin R. Howie ◽  
...  

Aims The primary aim of this study was to assess whether non-fatal postoperative venous thromboembolism (VTE) within six months of surgery influences the knee-specific functional outcome (Oxford Knee Score (OKS)) one year after total knee arthroplasty (TKA). Secondary aims were to assess whether non-fatal postoperative VTE influences generic health and patient satisfaction at this time. Methods A study of 2,393 TKAs was performed in 2,393 patients. Patient demographics, comorbidities, OKS, EuroQol five-dimension score (EQ-5D), and Forgotten Joint Score (FJS) were collected preoperatively and one year postoperatively. Overall patient satisfaction with their TKA was assessed at one year. Patients with VTE within six months of surgery were identified retrospectively and compared with those without. Results A total of 37 patients (1.5%) suffered a VTE and were significantly more likely to have associated comorbidities of stroke (p = 0.026), vascular disease (p = 0.026), and kidney disease (p = 0.026), but less likely to have diabetes (p = 0.046). In an unadjusted analysis, patients suffering a VTE had a significantly worse postoperative OKS (difference in mean (DIM) 4.8 (95% confidence interval (CI) 1.6 to 8.0); p = 0.004) and EQ-5D (DIM 0.146 (95% CI 0.059 to 0.233); p = 0.001) compared with patients without a VTE. After adjusting for confounding variables VTE remained a significant independent predictor associated with a worse postoperative OKS (DIM -5.4 (95% CI -8.4 to -2.4); p < 0.001), and EQ-5D score (DIM-0.169 (95% CI -0.251 to -0.087); p < 0.001). VTE was not independently associated with overall satisfaction after TKA (odds ratio 0.89 (95% CI 0.35 to 2.07); p = 0.717). Conclusion Patients who had a VTE within six months of their TKA had clinically significantly worse knee-specific outcome (OKS) and general health (EQ-5D) scores one year postoperatively, but the overall satisfaction with their TKA was similar to those patients who did not have a VTE. Cite this article: Bone Joint J 2021;103-B(7):1254–1260.


PLoS ONE ◽  
2018 ◽  
Vol 13 (10) ◽  
pp. e0205492
Author(s):  
Igor Komnik ◽  
Sina David ◽  
Johannes Funken ◽  
Christine Haberer ◽  
Wolfgang Potthast ◽  
...  

The Knee ◽  
2018 ◽  
Vol 25 (6) ◽  
pp. 1262-1271 ◽  
Author(s):  
Monther A. Gharaibeh ◽  
Elizabeth Monk ◽  
Darren B. Chen ◽  
Samuel J. MacDessi

Author(s):  
Kartik M. Varadarajan ◽  
Angela Moynihan ◽  
Darryl D’Lima ◽  
Clifford W. Colwell ◽  
Harry E. Rubash ◽  
...  

Accurate knowledge of in vivo articular contact kinematics and contact forces is required to quantitatively understand factors limiting life of total knee arthroplasty (TKA) implants, such as polyethylene component wear and implant loosening [1]. Determination of in vivo tibiofemoral contact forces has been a challenging issue in biomechanics. Historically, instrumented tibial implants have been used to measure tibiofemoral forces in vitro [2] and computational models involving inverse dynamic optimization have been used to estimate joint forces in vivo [3]. Recently, D’Lima et al. reported the first in vivo measurement of 6DOF tibiofemoral forces via an instrumented implant in a TKA patient [4]. However this technique does not provide a direct estimation of tibiofemoral contact forces in the medial and lateral compartments. Recently, a dual fluoroscopic imaging system has been used to accurately determine tibiofemoral contact locations on the medial and lateral tibial polyethylene surfaces [5]. The objective of this study was to combine the dual fluoroscope technique and the instrumented TKAs to determine the dynamic 3D articular contact kinematics and contact forces on the medial and lateral tibial polyethylene surfaces during functional activities.


2021 ◽  
Vol 13 ◽  
Author(s):  
Dong Oh Ko ◽  
Song Lee ◽  
Jin Hak Kim ◽  
Il Chan Hwang ◽  
Sung Jun Jang ◽  
...  

2018 ◽  
Vol 46 (5) ◽  
pp. 1919-1927 ◽  
Author(s):  
Hirotaka Mutsuzaki ◽  
Arata Watanabe ◽  
Tomonori Kinugasa ◽  
Kotaro Ikeda

Objective To analyse location and frequency, and change over time, of radiolucent lines (RLLs) around trabecular metal tibial components in total knee arthroplasty (TKA). Methods Osteoarthritic knees in patients who had undergone TKA were retrospectively evaluated via analysis of RLLs on anteroposterior and lateral X-rays obtained at 2 and 6 months, and 1, 2 and 3 years following TKA. Results In 125 osteoarthritic knees from 90 patients (mean age, 75.0 ± 6.2; 21 male/69 female), frequency of RLLs around trabecular metal tibial components was generally highest at 2 and 6 months, and 1 year following TKA, then gradually decreased over the 3-year follow-up. Frequency of RLLs around trabecular metal tibial components was greater at the tip of the two pegs, particularly the medial peg, and around the pegs, versus other zones. No postoperative revisions were performed for loosening. Conclusions Over 3 years following TKA, RLLs were most frequently observed up to 1 year, then gradually decreased. RLLs were significantly more frequent in the medial peg zone and zones close to the medial peg than in other zones.


2018 ◽  
Vol 33 (12) ◽  
pp. 3660-3665 ◽  
Author(s):  
Jayson D. Zadzilka ◽  
Alison K. Klika ◽  
Cecilia Calvo ◽  
Juan C. Suarez ◽  
Preetesh D. Patel ◽  
...  

2021 ◽  
Vol 103-B (6 Supple A) ◽  
pp. 23-31
Author(s):  
Robert A. Burnett III ◽  
JaeWon Yang ◽  
P. Maxwell Courtney ◽  
E. Bailey Terhune ◽  
Charles P. Hannon ◽  
...  

Aims The aim of this study was to compare ten-year longitudinal healthcare costs and revision rates for patients undergoing unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA). Methods The Humana database was used to compare 2,383 patients undergoing UKA between 2007 and 2009, who were matched 1:1 from a cohort of 63,036 patients undergoing primary TKA based on age, sex, and Elixhauser Comorbidity Index. Medical and surgical complications were tracked longitudinally for one year following surgery. Rates of revision surgery and cumulative mean healthcare costs were recorded for this period of time and compared between the cohorts. Results Patients undergoing TKA had significantly higher rates of manipulation under anaesthesia (3.9% vs 0.9%; p < 0.001), deep vein thrombosis (5.0% vs 3.1%; p < 0.001), pulmonary embolism (1.5% vs 0.8%; p = 0.001), and renal failure (4.2% vs 2.2%; p < 0.001). Revision rates, however, were significantly higher for UKA at five years (6.0% vs 4.2%; p = 0.007) and ten years postoperatively (6.5% vs 4.4%; p = 0.002). Longitudinal-related healthcare costs for patients undergoing TKA were greater than for those undergoing UKA at one year ($24,771 vs $22,071; p < 0.001) and five years following surgery ($26,549 vs $25,730; p < 0.001); however, the mean costs of TKA were comparable to UKA at ten years ($26,877 vs $26,891; p = 0.425). Conclusion Despite higher revision rates, patients undergoing UKA had lower mean healthcare costs than those undergoing TKA up to ten years following the procedure, at which time costs were comparable. In the era of value-based care, surgeons and policymakers should be aware of the costs involved with these procedures. UKA was associated with fewer complications at one year postoperatively but higher revision rates at five and ten years. While UKA was significantly less costly than TKA at one and five years, costs at ten years were comparable with a mean difference of only $14. Lowering the risk of revision surgery should be targeted as a source of cost savings for both UKA and TKA as the mean related healthcare costs were 2.5-fold higher in patients requiring revision surgery. Cite this article: Bone Joint J 2021;103-B(6 Supple A):23–31.


Sign in / Sign up

Export Citation Format

Share Document