Mid-term results of Eclipse total shoulder arthroplasty

2022 ◽  
Vol 104-B (1) ◽  
pp. 83-90
Author(s):  
Timothy J. Batten ◽  
Sian Gallacher ◽  
Jonathan P. Evans ◽  
Richard J. Harding ◽  
Jeffrey Kitson ◽  
...  

Aims The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up. Methods Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency, rotator cuff failure, and glenoid loosening. Results Mean OSS at mean follow-up of 6.67 years (5.0 to 10.74) was 40.12 (9 to 48), with no statistically significant difference between those implanted for a non-OA indication and those for OA (p = 0.056) or time-dependent deterioration between two years and five years (p = 0.206). Ranges of motion significantly improved compared with preoperative findings and were maintained between two and five years with a mean external rotation of 38° (SD 18.1, 0 to 100) and forward elevation of 152° (SD 29.9, 90 to 180). Of those components with radiographs suitable for analysis (n = 83), 23 (28%) were found to have a least one humeral radiolucent line, which were predominantly incomplete, less than 2 mm, and in a single anatomical zone. No humeral components were loose. A radiolucent line was present around 22 (15%) of glenoid components, and 15 (10%) of components had failed. Rotator cuff failure was found in 21 (15%) components. The mean time to either glenoid or rotator cuff failure was greater than three years following implantation. Survivorship was 96.4% (95% CI 91.6 to 98.5, number at risk 128) at five years, and 94.3% (95% CI 88.2 to 97.3, number at risk 76) at seven years, both of which compare favourably with best results taken from available registries. Conclusion Functional and radiological outcomes of the Eclipse stemless TSA are excellent, with no loose humeral components at minimum five-year follow-up. The presence of radiolucent lines is of interest and requires long-term observation but does not impact on the clinical results. Of the eight revisions required, this was predominantly for glenoid and rotator cuff failure. Cite this article: Bone Joint J 2022;104-B(1):83–90.

2021 ◽  
Author(s):  
Emily Lau ◽  
Alexander Pietroski ◽  
Sreten Franovic ◽  
Yang Zhou ◽  
Noah Kuhlmann ◽  
...  

Abstract Background: Reverse total shoulder arthroplasty (RSA) increases deltoid muscle fiber recruitment and tension to compensate for deficient rotator cuff activity; however, it is unclear whether the anterior or middle deltoid becomes dominant and how the muscle activation profile changes postoperatively. Using minimally invasive electromyography, this study evaluated the activity of the deltoid and surrounding muscles during shoulder motion to assess muscle activation changes post-RSA. Methods: In this observational study, we assessed change in preoperative to postoperative shoulder muscle activation in 10 patients over 6 months. Muscle activation was measured using 8 surface electrodes. Activation of the anterior, middle and posterior deltoid and surrounding muscles were recorded during shoulder abduction, flexion, external and internal rotation were quantified. One-way analysis of variance was used to identify significant differences in activation and time or speed. Least significant difference post hoc test was used to determine specific differences in muscle activation at subsequent time points. Results: RSA shoulders at 6 months postoperative showed a significant increase in activity of the middle deltoid predominantly. Middle deltoid activation increased during abduction (P < 0.001), flexion (P = 0.008), external (P < 0.001) and internal (P < 0.001) rotation. Conclusions: Our study demonstrates the middle deltoid predominates in rotator cuff function in RSA as defined by quantitative activation, significant involvement in all shoulder motions, and increased activation at subsequent times. These findings may help guide future RSA designs to optimize deltoid wrapping allowing for maximal strength and efficiency.


2020 ◽  
Vol 8 (8) ◽  
pp. 232596712094277
Author(s):  
Brandon J. Erickson ◽  
Daphne Ling ◽  
Alexandra Wong ◽  
Joshua S. Dines ◽  
David M. Dines ◽  
...  

Background: The number of rotator cuff repairs (RCRs) is increasing each year. Total shoulder arthroplasty (TSA) is a successful treatment option for patients with glenohumeral osteoarthritis with a functioning rotator cuff. Purpose/Hypothesis: The purposes of this study were to report the outcomes of TSA in patients with ipsilateral RCR and determine whether patients with a history of ipsilateral RCR who subsequently underwent TSA had differences in outcomes compared with matched controls who underwent TSA with no history of RCR. We hypothesized that patients with prior RCR will have significant improvements in clinical outcome scores, with no difference in outcomes after TSA compared with those with no prior RCR. Study Design: Cohort study; Level of evidence, 3. Methods: Patients eligible for inclusion were those with a history of prior RCR who underwent TSA at a single institution with a minimum 2-year follow-up between 2000 and 2015. Outcomes for this group, including American Shoulder and Elbow Surgeons (ASES) scores, were reported and then compared with a matched control group of patients who underwent TSA with no history of prior RCR. Controls were matched based on age, sex, and preoperative ASES score. Results: Overall, 14 patients (64% males; mean ± SD age, 65.1 ± 11.1 years) underwent prior ipsilateral RCR before TSA. ASES scores significantly improved from 42.9 to 78.5 at 2 years and to 86.6 at 5 years. When compared with 42 matched control patients (matched 1:3) who underwent TSA with no history of RCR, there was no significant difference in ASES scores at 2 years (78.5 vs 85.3; P = .19) and 5 years (86.6 vs 90.9; P = .72) between the prior RCR and no RCR groups. Conclusion: TSA in patients with a history of prior ipsilateral RCR led to significant improvements in clinical outcomes. No difference in clinical outcomes at 2 or 5 years after TSA was found between patients with and without a history of prior ipsilateral RCR.


Joints ◽  
2021 ◽  
Author(s):  
Cassandra Lawrence ◽  
Mark Lazarus ◽  
Joseph Abboud ◽  
Gerald Williams ◽  
Surena Namdari

Abstract Background Compared with anatomic total shoulder arthroplasty (aTSA), reverse total shoulder arthroplasty (RTSA) is associated with lower preoperative and postoperative outcome scores and range of motion. It is unknown whether patients' preoperative expectations of surgery are lower in RTSA compared with aTSA. The purpose of this study was to assess preoperative patient expectations and postoperative outcomes in aTSA and RTSA. Methods A consecutive series of patients undergoing primary aTSA for diagnosis of osteoarthritis or primary RTSA for diagnosis of rotator cuff tear arthropathy were studied prospectively. Expectations were evaluated using the validated Hospital for Special Surgery's Shoulder Surgery Expectations Survey. Baseline demographics, comorbidities, and social factors were collected. Baseline and 2 years postoperative American Shoulder and Elbow Surgeons (ASES) score, visual analog scale pain, Single Assessment Number Evaluation (SANE), and patient satisfaction were obtained. Results There were 128 patients (64 aTSA and 64 RTSA). There was no significant difference in total preoperative expectations score between groups. On multivariate linear regression analysis, aTSA (p = 0.024) and younger age (p = 0.018) were associated with higher expectations for improved ability to exercise. Changes in preoperative to postoperative ASES (p = 0.004) and SANE (p = 0.001) scores were higher in the aTSA group. Total preoperative expectations score was not correlated with postoperative functional outcomes or satisfaction in either group. In the aTSA group, expectations for participation in exercise were positively correlated with changes in preoperative to postoperative ASES score (p = 0.01) and SANE score (p = 0.01). Conclusion Though patients undergoing primary aTSA demonstrated greater improvement in functional outcome than those undergoing primary RTSA, both groups reported similar aggregate preoperative expectations. Those undergoing aTSA had higher expectations for return to exercise which was positively correlated with postoperative functional outcomes. Level of Evidence Level II, prospective cohort study.


Joints ◽  
2021 ◽  
Author(s):  
Riccardo Luigi Alberio ◽  
Marco Landrino ◽  
Paolo Fornara ◽  
Federico Alberto Grassi

Abstract Purpose This article compares short-term outcomes of two series of patients, who underwent reverse total shoulder arthroplasty (RTSA) with two different implants, both based on Grammont's principles: the Delta III (D-3) and the Delta Xtend (D-XT) prostheses. Methods The D-3 group included a consecutive series of 26 patients (mean age 75 years), that were treated between 2000 and 2006; the D-XT group included a consecutive series of 31 patients (mean age 72.5 years), for a total of 33 implants performed between 2011 and 2015. In both groups the most common diagnoses were cuff tear arthropathy (18 and 22 shoulders, respectively) and malunion of proximal humerus fractures (3 and 5). All procedures were performed by the same surgeon. Constant–Murley score (CMS) was used to assess clinical and functional outcomes. Radiographic evaluation included the true anteroposterior and axillary views. Results Twenty-three patients of the D-3 group and 22 patients (24 shoulders) of the D-XT group were evaluated at a mean follow-up of 42 months (range 26–84) and 44 months (range 26–66), respectively. Four complications occurred in the D-3 group (1 partial deltoid detachment, 1 dislocation, and 2 glenoid component loosening), while one early postoperative infection occurred in the D-XT group. Increases in elevation and CMS between preoperative and postoperative period were observed in both groups; only the D-XT group showed a slight improvement in rotations. The incidence of scapular notching was significantly different between the two groups: 100% for D-3 and 22.2% for D-XT in patients with a minimum follow-up of 5 years. Conclusion Prosthetic design evolution and greater acquaintance with this surgery have undoubtedly led to an improvement in short-term outcomes with second generation implants of RTSA. Future studies will have to ascertain whether newer implants, relying on biomechanical solutions alternative to Grammont's original concept, might provide additional advantages and minimize drawbacks.


2021 ◽  
pp. 175857322110588
Author(s):  
William R Aibinder ◽  
Fares Uddin ◽  
Ryan T Bicknell ◽  
Ryan Krupp ◽  
Markus Scheibel ◽  
...  

Background Finite element analysis has suggested that stemless implants may theoretically decrease stress shielding. The purpose of this study was to assess the radiographic proximal humeral bone adaptations seen following stemless anatomic total shoulder arthroplasty. Methods A retrospective review of 152 prospectively followed stemless total shoulder arthroplasty utilizing a single implant design was performed. Anteroposterior and lateral radiographs were reviewed at standard time points. Stress shielding was graded as mild, moderate, and severe. The effect of stress shielding on clinical and functional outcomes was assessed. Also, the influence of subscapularis management on the occurrence of stress shielding was determined. Results At 2 years postoperatively, stress shielding was noted in 61 (41%) shoulders. A total of 11 (7%) shoulders demonstrated severe stress shielding with 6 occurring along the medial calcar. There was one instance of greater tuberosity resorption. At the final follow-up, no humeral implants were radiographically loose or migrated. There was no statistically significant difference in clinical and functional outcomes between shoulders with and without stress shielding. Patients undergoing a lesser tuberosity osteotomy had lower rates of stress shielding, which was statistically significant ( p = 0.021) Discussion Stress shielding does occur at higher rates than anticipated following stemless total shoulder arthroplasty, but was not associated with implant migration or failure at 2 years follow-up. Level of evidence IV, Case series.


2019 ◽  
Author(s):  
Dong Min Kim ◽  
Mohammed Aldeghaither ◽  
Fahad Alabdullatif ◽  
Myung Jin Shin ◽  
Erica Kholinne ◽  
...  

Abstract Background: Modern designs of metal-backed glenoids (MBG) have been devised to overcome flaws such as loosening and a high failure rate.This review aimed to compare rates of complications and revision surgeries between the modern metal-backed glenoid (MBG) and the cemented polyethylene glenoid (PEG).Methods: Literature search was carried out using PubMed, Cochrane Library, EMBASE, and Google Scholar using MeSH terms and natural keywords. A total of 1186 articles were screened. We descriptively analyzed numerical data between the groups and statistically analyzed the categorical data, such as the presence of radiolucent line, loosening, and revision surgery (failure). Articles were divided into 3 groups based on follow-up duration: short-term < 36 months, midterm 36–72 months, and long-term > 72 months.Results: This study included 35 articles (3769 shoulders); 25 on cemented PEG and ten on the modern MBG. Mean age was 66.4 (21–93) and 66.5 years (31–88). The mean duration of follow-up was 73.1 (12–211) and 56.1 months (24–100). Overall, the rate of the radiolucent line was 354/1302 (27%) and 47/282 (17%), the loosening rate was 465/3185 (15 %) and 22/449 (5%), and the failure rate was 189/3316 (6%) and 11/457 (2%), for PEG and MBG, respectively. The results of short- and mid-term FU studies showed lower rates of radiolucency and loosening in the cemented PEG group, but there was no significant difference in failure rate (P=0.754 and 0.829, respectively). In long-term FU, MBG was better in terms of loosening (P <0.001) and failure rates (P = 0.006).Conclusions: The modern MBG component, especially TM glenoid, seems to be a promising alternative to cemented PEGs, based on subgroup revision rates according to the follow-up duration and overall results of ROM and clinical scores. All polyethylene glenoids tend to increase loosening and failure over time. The modern MBG seems to have no difference in failure, at least in the short- and mid-term compared to the cemented PEG. More long-term follow-up studies on modern MBG should be ultimately conducted.


2020 ◽  
Author(s):  
Dong Min Kim ◽  
Mohammed Aldeghaither ◽  
Fahad Alabdullatif ◽  
Myung Jin Shin ◽  
Erica Kholinne ◽  
...  

Abstract Background: Modern designs of metal-backed glenoids (MBG) have been devised to overcome flaws such as loosening and a high failure rate. This review aimed to compare rates of complications and revision surgeries between the modern metal-backed glenoid (MBG) and the cemented polyethylene glenoid (PEG).Methods: Literature search was carried out using PubMed, Cochrane Library, EMBASE, and Google Scholar using MeSH terms and natural keywords. A total of 1186 articles were screened. We descriptively analyzed numerical data between the groups and statistically analyzed the categorical data, such as the presence of radiolucent line, loosening, and revision surgery (failure). Articles were divided into 3 groups based on follow-up duration: short-term < 36 months, midterm 36–72 months, and long-term > 72 months.Results: This study included 35 articles (3769 shoulders); 25 on cemented PEG and ten on the modern MBG. Mean age was 66.4 (21–93) and 66.5 years (31–88). The mean duration of follow-up was 73.1 (12–211) and 56.1 months (24–100). Overall, the rate of the radiolucent line was 354/1302 (27%) and 47/282 (17%), the loosening rate was 465/3185 (15 %) and 22/449 (5%), and the failure rate was 189/3316 (6%) and 11/457 (2%), for PEG and MBG, respectively. The results of short- and mid-term FU studies showed lower rates of radiolucency and loosening in the cemented PEG group, but there was no significant difference in failure rate (P=0.754 and 0.829, respectively). In long-term FU, MBG was better in terms of loosening (P <0.001) and failure rates (P = 0.006).Conclusions: The modern MBG component, especially TM glenoid, seems to be a promising alternative to cemented PEGs, based on subgroup revision rates according to the follow-up duration and overall results of ROM and clinical scores. All polyethylene glenoids tend to increase loosening and failure over time. The modern MBG seems to have no difference in failure, at least in the short- and mid-term compared to the cemented PEG. More long-term follow-up studies on modern MBG should be ultimately conducted.


2021 ◽  
pp. 175857322110133
Author(s):  
Eva Y Liu ◽  
Dorsa Kord ◽  
Nicholas J Yee ◽  
Nolan S Horner ◽  
Latifah Al Mana ◽  
...  

Introduction Stemless reverse total shoulder arthroplasty is used to treat rotator cuff deficient arthropathies, rheumatoid arthritis, and osteoarthritis. It has several advantages over the stemmed implant including preservation of bone stock, reduced surgical time, and easier revision. Methods A systematic search was conducted in MEDLINE, EMBASE, PubMed, and CENTRAL to retrieve all relevant studies evaluating stemless reverse total shoulder arthroplasty. Results The literature search identified 1993 studies out of which 7 studies were included in this review; 324 patients underwent stemless reverse total shoulder arthroplasty with a weighted mean age of 74.1 (SD = 8.6, range = 38 to 93) years and a weighted mean follow-up time of 44 (SD = 6.6, range = 3 to 95) months. The included studies reported significant improvements in range of motion and functional scores comparable to stemmed reverse total shoulder arthroplasty. The weight mean flexion and abduction was (135 ± 12)° and (131 ± 12)° post-operatively, respectively. The weighted mean constant score increased from (26.7 ± 5.2) Patients (pts) to (63.0 ± 8.0) pts post-operatively. Overall complication and revision rate were 12.3% and 5.2%. Conclusion Early and mid-term results indicate stemless reverse total shoulder arthroplasty has similar clinical outcomes to stemmed reverse total shoulder arthroplasty. There was no radiological evidence of humeral loosening at the latest follow-up.


2021 ◽  
Vol 103-B (8) ◽  
pp. 1333-1338
Author(s):  
Pradeep Kankanalu ◽  
Zakk M. Borton ◽  
Marie L. Morgan ◽  
Tim Cresswell ◽  
Marius P. Espag ◽  
...  

Aims Reverse total shoulder arthroplasty (RTSA) using trabecular metal (TM)-backed glenoid implants has been introduced with the aim to increase implant survival. Only short-term reports on the outcomes of TM-RTSA have been published to date. We aim to present the seven-year survival of TM-backed glenoid implants along with minimum five-year clinical and radiological outcomes. Methods All consecutive elective RTSAs performed at a single centre between November 2008 and October 2014 were reviewed. Patients who had primary TM-RTSA for rotator cuff arthropathy and osteoarthritis with deficient cuff were included. A total of 190 shoulders in 168 patients (41 male, 127 female) were identified for inclusion at a mean of 7.27 years (SD 1.4) from surgery. The primary outcome was survival of the implant with all-cause revision and aseptic glenoid loosening as endpoints. Secondary outcomes were clinical, radiological, and patient-related outcomes with a five-year minimum follow-up. Results The implant was revised in ten shoulders (5.2%) with a median time to revision of 21.2 months (interquartile range (IQR) 9.9 to 41.8). The Kaplan-Meier survivorship estimate at seven years was 95.9% (95% confidence interval (CI) 91.7 to 98; 35 RTSAs at risk) for aseptic mechanical failure of the glenoid and 94.8% (95% CI 77.5 to 96.3; 35 RTSAs at risk) for all-cause revision. Minimum five-year clinical and radiological outcomes were available for 103 and 98 RTSAs respectively with a median follow-up time of six years (IQR 5.2 to 7.0). Median postoperative Oxford Shoulder Score was 38 (IQR 31 to 45); median Constant and Murley score was 60 (IQR 47.5 to 70); median forward flexion 115° (IQR 100° to 125°); median abduction 95° (IQR 80° to 120°); and external rotation 25° (IQR 15° to 40°) Scapular notching was seen in 62 RTSAs (63.2%). Conclusion We present the largest and longest-term series of TM-backed glenoid implants demonstrating 94.8% all-cause survivorship at seven years. Specifically pertaining to glenoid loosening, survival of the implant increased to 95.9%. In addition, we report satisfactory minimum five-year clinical and radiological outcomes. Cite this article: Bone Joint J 2021;103-B(8):1333–1338.