High Speed, Spectrometer Based Optical Coherence Tomography at 1050 nm for Isotropic 3D OCT Imaging and Visualization of Retinal and Choroidal Vasculature

2008 ◽  
Author(s):  
Boris Považay ◽  
Boris Hermann ◽  
Vedran Kajić ◽  
Bernd Hofer ◽  
Wolfgang Drexler
2019 ◽  
Vol 2 (1) ◽  
pp. 46-54
Author(s):  
Dita Mintardi ◽  
AK Ansyori ◽  
Ramzi Amin

Optical Coherence Tomography Angiography (OCTA) is a new high-resolution imaging method for visualizing retinal and choroidal circulation without any dye injection By detecting intravascular flow quickly when needed and being able to repeat images, as often as needed, without risk to patients, doctors will value OCTA as one of the most important applications of OCT imaging because of its ability to offer precise visualization of intravascular flow in the inner retina layer and outside, as well as the inner choroid. OCTA uses high-speed structural OCT imaging and provides three-dimensional data about microvascular structures, enabling visualization of the en face apart from the retinal capillary plexus and choriocapillaris, combined with co-registered en face and cross-sectional structural OCT. Although OCTA is a strong modality, it can have imaging artifacts and provide information that is inherently more complex than structural OCT alone. Successful interpretation of OCTA findings requires an understanding of how OCTA works, the relationship of various ocular pathologies to its angiographic features, and integrated assessment of angiographic and structural OCT data.


2020 ◽  
Vol 10 (14) ◽  
pp. 4936
Author(s):  
Pingping Jia ◽  
Hong Zhao ◽  
Yuwei Qin

A high-speed, high-resolution swept-source optical coherence tomography (SS-OCT) is presented for focusing lens imaging and a k-domain uniform algorithm is adopted to find the wave number phase equalization. The radius of curvature of the laser focusing lens was obtained using a curve-fitting algorithm. The experimental results demonstrate that the measuring accuracy of the proposed SS-OCT system is higher than the laser confocal microscope. The SS-OCT system has great potential for surface topography measurement and defect inspection of the focusing lens.


Author(s):  
Rajgopal Mani ◽  
Jon Holmes ◽  
Kittipan Rerkasem ◽  
Nikolaos Papanas

Dynamic optical coherence tomography (D-OCT) is a relatively new technique that may be used to study the substructures in the retina, in the skin and its microcirculation. Furthermore, D-OCT is a validated method of imaging blood flow in skin microcirculation. The skin around venous and mixed arterio-venous ulcers was imaged and found to have tortuous vessels assumed to be angiogenic sprouts, and classified as dots, blobs, coils, clumps, lines, and curves. When these images were analyzed and measurements of vessel density were made, it was observed that the prevalence of coils and clumps in wound borders was significantly greater compared with those at wound centers. This reinforced the belief of inward growth of vessels from wound edge toward wound center which, in turn, reposed confidence in following the wound edge to study healing. D-OCT imaging permits the structure and the function of the microcirculation to be imaged, and vessel density measured. This offers a new vista of skin microcirculation and using it, to better understand angiogenesis in chronic wounds.


2021 ◽  
pp. 153537022110285
Author(s):  
Hao Zhou ◽  
Tommaso Bacci ◽  
K Bailey Freund ◽  
Ruikang K Wang

The choroid provides nutritional support for the retinal pigment epithelium and photoreceptors. Choroidal dysfunction plays a major role in several of the most important causes of vision loss including age-related macular degeneration, myopic degeneration, and pachychoroid diseases such as central serous chorioretinopathy and polypoidal choroidal vasculopathy. We describe an imaging technique using depth-resolved swept-source optical coherence tomography (SS-OCT) that provides full-thickness three-dimensional (3D) visualization of choroidal anatomy including topographical features of individual vessels. Enrolled subjects with different clinical manifestations within the pachychoroid disease spectrum underwent 15 mm × 9 mm volume scans centered on the fovea. A fully automated method segmented the choroidal vessels using their hyporeflective lumens. Binarized choroidal vessels were rendered in a 3D viewer as a vascular network within a choroidal slab. The network of choroidal vessels was color depth-encoded with a reference to the Bruch’s membrane segmentation. Topographical features of the choroidal vasculature were characterized and compared with choroidal imaging obtained with indocyanine green angiography (ICGA) from the same subject. The en face SS-OCT projections of the larger choroid vessels closely resembled to that obtained with ICGA, with the automated SS-OCT approach proving additional depth-encoded 3D information. In 16 eyes with pachychoroid disease, the SS-OCT approach added clinically relevant structural details, including choroidal thickness and vessel depth, which the ICGA studies could not provide. Our technique appears to advance the in vivo visualization of the full-thickness choroid, successfully reveals the topographical features of choroidal vasculature, and shows potential for further quantitative analysis when compared with other choroidal imaging techniques. This improved visualization of choroidal vasculature and its 3D structure should provide an insight into choroid-related disease mechanisms as well as their responses to treatment.


2021 ◽  
pp. 247412642199733
Author(s):  
Kyle D. Kovacs ◽  
M. Abdallah Mahrous ◽  
Luis Gonzalez ◽  
Benjamin E. Botsford ◽  
Tamara L. Lenis ◽  
...  

Purpose: This work aims to evaluate the clinical utility and feasibility of a novel scanning laser ophthalmoscope-based navigated ultra-widefield swept-source optical coherence tomography (UWF SS-OCT) imaging system. Methods: A retrospective, single-center, consecutive case series evaluated patients between September 2019 and October 2020 with UWF SS-OCT (modified Optos P200TxE, Optos PLC) as part of routine retinal care. The logistics of image acquisition, interpretability of images captured, nature of the peripheral abnormality, and clinical utility in management decisions were recorded. Results: Eighty-two eyes from 72 patients were included. Patients were aged 59.4 ± 17.1 years (range, 8-87 years). During imaging, 4.4 series of images were obtained in 4.1 minutes, with 86.4% of the image series deemed to be diagnostic of the peripheral pathology on blinded image review. The most common pathologic findings were chorioretinal scars (18 eyes). In 31 (38%) eyes, these images were meaningful in supporting clinical decision-making with definitive findings. Diagnoses imaged included retinal detachment combined with retinoschisis, retinal hole with overlying vitreous traction and subretinal fluid, vitreous inflammation overlying a peripheral scar, Coats disease, and peripheral retinal traction in sickle cell retinopathy. Conclusions: Navigated UWF SS-OCT imaging was clinically practical and provided high-quality characterization of peripheral retinal lesions for all eyes. Images directly contributed to management plans, including laser, injection or surgical treatment, for a clinically meaningful set of patients (38%). Future studies are needed to further assess the value of this imaging modality and its role in diagnosing, monitoring, and treating peripheral lesions.


2020 ◽  
pp. 1-9
Author(s):  
Sabrina Bergeron ◽  
Bryan Arthurs ◽  
Debra-Meghan Sanft ◽  
Christina Mastromonaco ◽  
Miguel N. Burnier Jr.

<b><i>Introduction:</i></b> Optical coherence tomography (OCT) imaging has been used as a diagnostic tool for retinal disease for several years, and OCT apparatuses are becoming increasingly powerful. However, OCT has yet to reach its full potential in ophthalmology clinics. Alike retinal layers, it has been shown that OCT is able to generate cross-sectional images of the skin and allows visualization of skin lesions in a histopathology-like manner. <b><i>Objective:</i></b> We aim to validate OCT as an imaging modality for peri-ocular skin cancer. Through a series of cases, we highlight findings for 3 common eyelid malignancies: basal cell carcinoma, squamous cell carcinoma and sebaceous carcinoma. We propose an OCT image-based signature for basal cell carcinoma. <b><i>Methods:</i></b> This is a prospective study. Fifty-eight lesions suspicious of malignancy from 57 patients were subjected to OCT imaging prior to the surgical excision of the lesion. OCT images were analysed and scored according to previously identified OCT features. Eight representative examples are presented, highlighting the OCT patterns for each malignancy side by side to its corresponding histopathological sections. <b><i>Results:</i></b> Out of the 58 lesions analysed, 53 were malignant. A loss of the dermal-epidermal junction is observed in all malignant lesions. A strong link is observed between the presence of subepithelial hyporeflective nests on OCT and the diagnosis of basal cell carcinoma (present in 83% of cases). Conversely, lesions of epithelial origin such as squamous cell carcinoma are most often represented on OCT by acanthosis. Two supplementary cases, one basal cell carcinoma and one sebaceous carcinoma, are provided to illustrate how OCT imaging is a valuable tool in cases where clinical observations may be unusual. <b><i>Conclusions:</i></b> We provide evidence supporting the use of OCT for the evaluation of peri-ocular cancers. OCT enables visualization of the skin layers in vivo, before biopsy. Our results show that certain OCT features can contribute to include or exclude a diagnosis of basal cell carcinoma. By integrating this non-invasive imaging methodology into the routine assessment of peri-ocular skin lesions, especially in health care centres where access to specialists is limited, OCT imaging can increase clinical precision, reduce delays in patient referral and enhance patient care.


2021 ◽  
pp. 159101992110034
Author(s):  
Andre Monteiro ◽  
Demetrius K Lopes ◽  
Amin Aghaebrahim ◽  
Ricardo Hanel

Purpose Flow-diverters have revolutionized the endovascular treatment of intracranial aneurysms, offering a durable solution to aneurysms with high recurrence rates after conventional stent-assisted coiling. Events that occur after treatment with flow-diversion, such as in-stent stenosis (ISS) are not well understood and require further assessment. After assessing an animal model with Optical Coherence Tomography (OCT), we propose a concept that could explain the mechanism causing reversible ISS after treatment of intracranial aneurysms with flow-diverters. Methods Six Pipeline Flex embolization devices (PED-Flex), six PED with Shield technology (PED-Shield), and four Solitaire AB devices were implanted in the carotid arteries (two stents per vessel) of four pigs. Intravascular optical coherence tomography (OCT) and digital subtraction angiography (DSA) images obtained on day 21 were compared to histological specimens. Results A case of ISS in a PED-Flex device was assessed with OCT imaging. Neointima with asymmetrical topography completely covering the PED struts was observed. Histological preparations of the stenotic area demonstrated thrombus on the surface of device struts, covered by neointima. Conclusion This study provides a plausible concept for reversible ISS in flow-diverters. Based on an observation of a previous experiment, we propose that similar cases of ISS are related to thrombus presence underneath endothelization, but further experiments focused on this phenomenon are needed. Optical Coherence Tomography will be useful tool when available for clinical use.


2007 ◽  
Vol 15 (26) ◽  
pp. 18130 ◽  
Author(s):  
Ki Hean Kim ◽  
B. Hyle Park ◽  
Gopi N. Maguluri ◽  
Tom W. Lee ◽  
Fran J. Rogomentich ◽  
...  

2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Yi Sun ◽  
Jianfeng Wang ◽  
Jindou Shi ◽  
Stephen A. Boppart

AbstractPolarization-sensitive optical coherence tomography (PS-OCT) is a high-resolution label-free optical biomedical imaging modality that is sensitive to the microstructural architecture in tissue that gives rise to form birefringence, such as collagen or muscle fibers. To enable polarization sensitivity in an OCT system, however, requires additional hardware and complexity. We developed a deep-learning method to synthesize PS-OCT images by training a generative adversarial network (GAN) on OCT intensity and PS-OCT images. The synthesis accuracy was first evaluated by the structural similarity index (SSIM) between the synthetic and real PS-OCT images. Furthermore, the effectiveness of the computational PS-OCT images was validated by separately training two image classifiers using the real and synthetic PS-OCT images for cancer/normal classification. The similar classification results of the two trained classifiers demonstrate that the predicted PS-OCT images can be potentially used interchangeably in cancer diagnosis applications. In addition, we applied the trained GAN models on OCT images collected from a separate OCT imaging system, and the synthetic PS-OCT images correlate well with the real PS-OCT image collected from the same sample sites using the PS-OCT imaging system. This computational PS-OCT imaging method has the potential to reduce the cost, complexity, and need for hardware-based PS-OCT imaging systems.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
R Bhoite ◽  
H Jinnouchi ◽  
F Otsuka ◽  
Y Sato ◽  
A Sakamoto ◽  
...  

Abstract Background In many studies, struts coverage is defined as &gt;0 mm of tissue overlying the stent struts by optical coherence tomography (OCT). However, this definition has never been validated using histology as the “gold standard”. The present study sought to assess the appropriate cut-off value of neointimal thickness of stent strut coverage by OCT using histology. Methods OCT imaging was performed on 39 human coronary arteries with stents from 25 patients at autopsy. A total of 165 cross-sectional images from 46 stents were co-registered with histology. The optimal cut-off value of strut coverage by OCT was determined. Strut coverage by histology was defined as endothelial cells with at least underlying two layers of smooth muscle cells. Considering the resolution of OCT is 10–20 μm, 3 different cut-off values (i.e. at ≥20, ≥40, and ≥60 μm) were assessed. Results A total of 2235 struts were evaluated by histology. Eventually, 1216 struts which were well-matched struts were analyzed in this study. By histology, uncovered struts were observed in 160 struts and covered struts were observed in 1056 struts. The broadly used definition of OCT-coverage which does not consider neointimal thickness yielded a poor specificity of 37.5% and high sensitivity 100%. Of 3 cut-off values, the cut-off value of &gt;40 μm was more accurate as compared to &gt;20 and &gt;60 mm [sensitivity (99.3%), specificity (91.0%), positive predictive value (98.6%), and negative predictive value (95.6%)] Conclusion The most accurate cut-off value was ≥40 μm neointimal thickness by OCT in order to identify stent strut coverage validated by histology. Funding Acknowledgement Type of funding source: None


Sign in / Sign up

Export Citation Format

Share Document