scholarly journals Development of a rapid and reliable high-performance liquid chromatography method for determination of water-soluble vitamins in veterinary feed premix

2021 ◽  
pp. 3084-3090
Author(s):  
Md. Zahangir Hosain ◽  
S. M. Shariful Islam ◽  
Md. Mostofa Kamal

Background and Aim: Determination of trace amounts of vitamins in multi-component feed premix is a troublesome analytical procedure. In this study, a simple and rapid high-performance liquid chromatography (HPLC) method was developed and validated for the concurrent detection and quantitation of four water-soluble vitamins such as thiamine, riboflavin, pyridoxine, and cyanocobalamin in veterinary feed premixes. Materials and Methods: The chromatographic separation of the vitamins was carried out at 35°C temperature on a reversed-phase C18 column using a gradient pump mode. Mobile phase constituents were solvent (a): 25 mM Potassium dihydrogen phosphate and 5 mM sodium hexanesulfonate in deionized water having pH-4.0 and solvent and (b) 5 mM sodium hexanesulfonate in methanol. Detection was performed with HPLC ultraviolet/visible detection set at 278 and 361 nm wavelength in two different channels. The flow rate was 1.2 mL/min and the total run time was 25 min. Results: The method was validated according to the International Conference on Harmonization and Food and Drug Administration guidelines and acceptance criteria for system suitability, precision, linearity, and recovery were met in all cases. The relative standard deviation for system suitability and precision was <2% for all vitamins. The linearity of the calibration curves was excellent (R2>0.999) at concentration of 5, 10, 15, 20, 25, and 30 μg/mL for all vitamins. The limits of detection values were 0.0125, 0.0017, 0.0064, and 0.0065 μg/mL for thiamine, riboflavin, pyridoxine, and cyanocobalamin, respectively, and the limits of quantification values were 0.0378, 0.0051, 0.0213, and 0.0198 μg/mL for thiamine, riboflavin, pyridoxine, and cyanocobalamin, respectively. The recovery percentages ranged from 88% to 115%. Conclusion: The overall parameters of the proposed method met the validation criteria and this method could be a highly desirable technique for routine analysis of water-soluble vitamins in veterinary feed premix.

2006 ◽  
Vol 89 (6) ◽  
pp. 1552-1556
Author(s):  
ArmaĞan Önal ◽  
Olcay SaĞiri ◽  
S Müge Çetin ◽  
Sidika Toker

Abstract Reboxetine is used as a selective noradrenaline reuptake inhibitor for the treatment of major depressive disorders. It is effective in the treatment of severe depression and safer to use than traditional tricyclic antidepressants. In this study, a novel, simple, and rapid stability-indicating high-performance liquid chromatography (HPLC) method for reboxetine methansulfonate was successfully developed and validated for the assay of tablets. The method was used to quantify reboxetine in tablets; it employed a C18 column (150 4.6 mm id) with an isocratic mobile phase consisting of methanolphosphate buffer (pH 7, 0.02 M; 55 + 45, v/v) at a flow rate of 1.0 μmL/min. Reboxetine was detected by an ultraviolet detector at 277 nm. The retention time of reboxetine was about 4.5 min. The developed HPLC method was validated with respect to linearity, precision, sensitivity, accuracy, and selectivity. The method was linear over the concentration range 150 g/mL (r 0.9999). The limits of detection and the quantitation of reboxetine were 0.1 and 0.3 μg/mL, respectively. The relative standard deviation values for intraday and interday precision were 0.781.01 and 1.081.37%, respectively. Selectivity was validated by subjecting a stock solution of reboxetine to neutral, acid, and alkali hydrolysis, as well as oxidation, dry heat treatment, and photodegradation. The peaks of the degradation products did not interfere with the peak of reboxetine. The results indicated that the proposed method could be used in a stability assay. The proposed method was successfully applied to the determination of reboxetine in tablets. Excipients present in the tablets did not interfere with the analysis.


2020 ◽  
Vol 8 (2) ◽  
pp. 1-7
Author(s):  
Ihsan M. Shaheed ◽  
Saadiyah A. Dhahir

The quinolizindine alkaloid compound, oxymatrine pesticide, was analysis in the river water samples collected from different agriculture areas in the Iraqi city of Kerbala and also in its formulation using developed reverse-phase high-performance liquid chromatography method. Acetonitrile:methanol (60:40 v/v) was chosen as mobile phase at pH (7.0), flow rate 0.5 mL/min, and 20 µL as volume injection. Modified ecological-friendly method, dispersive liquid-liquid microextraction, was used for the extraction of oxymatrine from water samples. Linearity study was constructed from 0.1 to 70 μg/mL at λmax 205 nm. The limit of detection and limit of quantification were 0.025 and 0.082 μg/mL, respectively, and the relative standard deviation (RSD) % was 0.518%. Three spiked levels of concentration (20.0, 40.0, and 70.0 μg/mL) were used for the validation method. The percentage recovery for the three spiked samples was ranged between 98.743 and 99.432 and the RSD% was between 0.051 and 0.202%, the formulation studies of oxymatrine between 99.487 and 99.798, and the RSD% was ranged from 0.045 to 0.057%. The developed method can be used accurately and selectively for the determination of oxymatrine in environmental samples and in the formulation.


2020 ◽  
Vol 17 (34) ◽  
pp. 1046-1054
Author(s):  
Ihsan Mahdi SHAHEED ◽  
Saadiyah Ahmed DHAHIR

The triazole, tebuconazole pesticide, was determined in its formulation and also in the river water samples collected from different agriculture areas in the Iraqui city of Kerbala using developed high-performance liquid chromatography method(HPLC) with UV-visible detection, The mobile composition phase was a mixture of acetonitrile:methanol (50:50 v/v) and the column was C18 (250 cm x 4.6 mm,5μm). Also modified dispersive liquidliquid microextraction (DLLME), which is regarded as an ecological -friendly method, was used for the extraction of tebuconazole from water samples using acetonitrile and chloroform as solvents extraction and dispersive agent, respectively. Linearity to maintain the calibration curve was achieved from (0.1-70) μg.mL-1 with a limit of detection(0.053) μg.mL-1 and limit of quantification (0.174) μg.mL-1. Three spiked levels of concentration (1.0, 5.0, and 10) μg.mL-1 were used for the validation of the method. The relative standard deviation (RSD%) was (0.294- 0.813)%, and the percentage recovery was (100.001-100.005). The formulation studies for two different concentrations (10 and 40) μg.mL-1, which prepared from tebuconazole formulation (Raxil ODS2 2%), gave acceptable percentage recovery between (98.956-99.833). The developed method can be used accurately for the determination of tebuconazole in water samples and in the formulation of tebuconazole effectively.


Separations ◽  
2021 ◽  
Vol 8 (8) ◽  
pp. 128
Author(s):  
Momochika Kumagai ◽  
Sanae Kato ◽  
Nanami Arakawa ◽  
Mika Otsuka ◽  
Takahisa Hamano ◽  
...  

The quantification of histidine-containing dipeptides (anserine, carnosine, and balenine) in serum might be a diagnostic tool to assess the health condition of animals. In this study, an existing reversed-phase ion-pair high-performance liquid chromatography (HPLC)–ultraviolet detection method was improved and validated to quantify serum anserine, carnosine, and balenine levels in the dolphin. The serum was deproteinized with trichloroacetic acid and directly injected into the HPLC system. Chromatographic separation of the three histidine-containing dipeptides was achieved on a TSK–gel ODS-80Ts (4.6 mm × 150 mm, 5 µm) analytical column using a mobile phase of 50 mmol/L potassium dihydrogen phosphate (pH 3.4) containing 6 mmol/L 1-heptanesulfonic acid and acetonitrile (96:4). The standard curve ranged from 0.1 µmol/L to 250 µmol/L. The average accuracy of the intra- and inter-analysis of anserine, carnosine, and balenine was 97–106%. The relative standard deviations of total precision (RSDr) of anserine, carnosine, and balenine in dolphin serum were 5.9%, 4.1%, and 2.6%, respectively. The lower limit of quantification of these compounds was 0.11–0.21 µmol/L. These results indicate that the improved method is reliable and concise for the simultaneous determination of anserine, carnosine, and balenine in dolphin serum, and may be useful for evaluation of health conditions in dolphins. Furthermore, this method can also be applied to other biological samples.


2016 ◽  
Vol 11 (11) ◽  
pp. 1934578X1601101 ◽  
Author(s):  
Chang-Seob Seo ◽  
Hyeun-Kyoo Shin

In Korean folk medicine, Melandrium firmum Rohrbach (Caryophyllaceae) has been used to treat various diseases, including anuria, breast cancer, and gonorrhea. In this study, a high-performance liquid chromatography method with photodiode-array UV detection (HPLC-PDA) was established and then validated for the simultaneous determination of five flavonoids in M. firmum: schaftoside, homoorientin, cytisoside, vitexin, and isovitexin. Separation of the five compounds was performed on a Gemini C18 column at 40°C by gradient elution of two mobile phases. The flow rate and injection volume were 1.0 mL/min and 10 μL, respectively. The HPLC-PDA method showed excellent linear regression with r2 values of 0.9999 within the test ranges. The limits of detection and quantification of all components were 0.01–0.11 and 0.04–0.34 μg/mL, respectively. The extraction recovery of the five analytes was 97.6—105.6% and the RSD values were < 2.0% The relative standard deviation values of intra- and interday precision for all analytes were < 1.71 and < 1.46%, respectively. As determined using the established and validated HPLC-PDA method described here, the amounts of the five marker compounds in M firmum were 0.02–2.54 mg/g.


2020 ◽  
Vol 20 (13) ◽  
pp. 1053-1059
Author(s):  
Mahmoud M. Sebaiy ◽  
Noha I. Ziedan

Background: Allergic diseases are considered as the major burden on public health with increased prevalence globally. Histamine H1-receptor antagonists are the foremost commonly used drugs in the treatment of allergic disorders. The target drug in this study, loratadine, belongs to this class of drugs and its biometabolite desloratadine which is also a non-sedating H1 receptor antagonist with anti-histaminic activity being 2.5 to 4 times greater than loratadine. This study aimed to develop and validate a novel isocratic Reversed-phase High-Performance Liquid Chromatography (RP-HPLC) method for rapid and simultaneous separation and determination of loratadine and its metabolite, desloratadine in human plasma. Methods: The drug extraction method from plasma was based on protein precipitation technique. The separation was carried out on a Thermo Scientific BDS Hypersil C18 column (5μm, 250 x 4.60 mm) in a mobile phase of MeOH: 0.025M KH2PO4 adjusted to pH 3.50 using orthophosphoric acid (85: 15, v/v) at an ambient temperature. The flow rate was maintained at 1 mL/min and maximum absorption was measured using the PDA detector at 248 nm. Results: The retention times of loratadine and desloratadine in plasma samples were recorded to be 4.10 and 5.08 minutes, respectively, indicating a short analysis time. Limits of detection were found to be 1.80 and 1.97 ng/mL for loratadine and desloratadine, respectively, showing a high degree of sensitivity of the method. The method was then validated according to FDA guidelines for the determination of the two analytes in human plasma. Conclusion: The results obtained indicate that the proposed method is rapid, sensitive in the nanogram range, accurate, selective, robust and reproducible compared to other reported methods.


2020 ◽  
Vol 16 ◽  
Author(s):  
Yun-Yan Xia ◽  
Qiao-Gen Zou ◽  
Yu-Fei Yang ◽  
Qian Sun ◽  
Cheng-Qun Han

Background: High-performance liquid chromatography (HPLC) method has been used to detect related impurities of perampanel. However, the detection of impurities is incomplete, and the limits of quantification and detection are high. A sensitive, reliable method is in badly to be developed and applied for impurity detection of perampanel bulk drug. Objective: Methodologies utilising HPLC and gas chromatography (GC) were established and validated for quantitative determination of perampanel and its related impurities (a total of 10 impurities including 2 genotoxic impurities). Methods: The separation was achieved on a Dikma Diamonsil C18 column (250 mm × 4.6 mm, 5 μm) with the mobile phase of 0.01 mol/L potassium dihydrogen phosphate solution (A) and acetonitrile (B) in gradient elution mode. The compound 2-bromopropane was determined on an Agilent DB-624 column (0.32 mm × 30 m, 1.8 μm) by electron capture detector (μ-ECD) with split injection ratio of 1:5 and proper gradient temperature program. Result: Both HPLC and GC methods were established and validated to be sensitive, accurate and robust according to International Council for Harmonization (ICH) guidelines. The methods developed were linear in the selected concentration range (R 2≥0.9944). The average recovery of all impurities was between 92.6% and 103.3%. The possible production mechanism of impurities during the synthesis and degradation processes of perampanel bulk drug was also discussed. Five impurities were analyzed by liquid chromatography–mass spectrometry (LC-MS). Moreover, two of them were simultaneously characterized by LC-MS, IR and NMR. Conclusion: The HPLC and GC methods were developed and optimized, which could be applied for quantitative detection of the impurities, and further stability study of perampanel.


2017 ◽  
Vol 2017 ◽  
pp. 1-7
Author(s):  
Paula Karina S. Uchoa ◽  
Leandro Bezerra de Lima ◽  
Antonia T. A. Pimenta ◽  
Maria da Conceição F. de Oliveira ◽  
Jair Mafezoli ◽  
...  

A high-performance liquid chromatography method was developed and validated for the quantification of the cytotoxic compounds produced by a marine strain ofAspergillus niger. The fungus was grown in malt peptone dextrose (MPD), potato dextrose yeast (PDY), and mannitol peptone yeast (MnPY) media during 7, 14, 21, and 28 days, and the natural products were identified by standard compounds. The validation parameters obtained were selectivity, linearity (coefficient of correlation > 0.99), precision (relative standard deviation below 5%), and accuracy (recovery > 96).