scholarly journals The Impact of Connecting Distributed Generation to the Distribution System

10.14311/986 ◽  
2007 ◽  
Vol 47 (4-5) ◽  
Author(s):  
E. V. Mgaya ◽  
Z. Müller

This paper deals with the general problem of utilizing of renewable energy sources to generate electric energy. Recent advances in renewable energy power generation technologies, e.g., wind and photovoltaic (PV) technologies, have led to increased interest in the application of these generation devices as distributed generation (DG) units. This paper presents the results of an investigation into possible improvements in the system voltage profile and reduction of system losses when adding wind power DG (wind-DG) to a distribution system. Simulation results are given for a case study, and these show that properly sized wind DGs, placed at carefully selected sites near key distribution substations, could be very effective in improving the distribution system voltage profile and reducing power losses, and hence could  improve the effective capacity of the system. 

2021 ◽  
Vol 11 (2) ◽  
pp. 774 ◽  
Author(s):  
Ahmed S. Abbas ◽  
Ragab A. El-Sehiemy ◽  
Adel Abou El-Ela ◽  
Eman Salah Ali ◽  
Karar Mahmoud ◽  
...  

In recent years, with the widespread use of non-linear loads power electronic devices associated with the penetration of various renewable energy sources, the distribution system is highly affected by harmonic distortion caused by these sources. Moreover, the inverter-based distributed generation units (DGs) (e.g., photovoltaic (PV) and wind turbine) that are integrated into the distribution systems, are considered as significant harmonic sources of severe harmful effects on the system power quality. To solve these issues, this paper proposes a harmonic mitigation method for improving the power quality problems in distribution systems. Specifically, the proposed optimal planning of the single tuned harmonic filters (STFs) in the presence of inverter-based DGs is developed by the recent Water Cycle Algorithm (WCA). The objectives of this planning problem aim to minimize the total harmonic distortion (THD), power loss, filter investment cost, and improvement of voltage profile considering different constraints to meet the IEEE 519 standard. Further, the impact of the inverter-based DGs on the system harmonics is studied. Two cases are considered to find the effect of the DGs harmonic spectrum on the system distortion and filter planning. The proposed method is tested on the IEEE 69-bus distribution system. The effectiveness of the proposed planning model is demonstrated where significant reductions in the harmonic distortion are accomplished.


Complexity ◽  
2017 ◽  
Vol 2017 ◽  
pp. 1-24 ◽  
Author(s):  
Marc Deissenroth ◽  
Martin Klein ◽  
Kristina Nienhaus ◽  
Matthias Reeg

The ongoing deployment of renewable energy sources (RES) calls for an enhanced integration of RES into energy markets, accompanied by a new set of regulations. In Germany, for instance, the feed-in tariff legislation for renewables has been successively replaced by first optional and then obligatory marketing of RES on competitive wholesale markets. This paper introduces an agent-based model that allows studying the impact of changing energy policy instruments on the economic performance of RES operators and marketers. The model structure, its components, and linkages are presented in detail; an additional case study demonstrates the capability of our sociotechnical model. We find that changes in the political framework cannot be mapped directly to RES operators as behaviour of intermediary market actors has to be considered as well. Characteristics and strategies of intermediaries are thus an important factor for successful RES marketing and further deployment. It is shown that the model is able to assess the emergence and stability of market niches.


2015 ◽  
Vol 785 ◽  
pp. 388-392 ◽  
Author(s):  
Hasmaini Mohamad ◽  
Shahrani Shahbudin ◽  
Nofri Yenita Dahlan

Interconnection of Distributed Generation (DG) in distribution system presents many potential benefits as well as drawbacks. The impacts of DG might vary with the types of generator. This paper presents a study on the impacts of synchronous DG's interconnection in distribution system. Steady state analysis is carried out to analyze the impact of DG on voltage profile and short circuit current considering before and after DG interconnection. Dynamic analysis is also performed for investigating the performance of DG when a part of distribution system is being islanded. Results show that the penetration of DG contributes to the changes of power flow in the system, hence give impacts to the overall system performance.


Author(s):  
N. Md. Saad ◽  
M. Z. Sujod ◽  
Lee Hui Ming ◽  
M. F. Abas ◽  
M. S. Jadin ◽  
...  

As the rapid development of photovoltaic (PV) technology in recent years with the growth of electricity demand, integration of photovoltaic distributed generation (PVDG) to the distribution system is emerging to fulfil the demand. There are benefits and drawbacks to the distribution system due to the penetration of PVDG. This paper discussed and investigated the impacts of PVDG location and size on distribution power systems. The medium voltage distribution network is connected to the grid with the load being supplied by PVDG. Load flow and short circuit calculation are analyzed by using DigSILENT Power Factory Software. Comparisons have been made between the typical distribution system and the distribution system with the penetration of PVDG. Impacts in which PVDG location and size integrates with distribution system are investigated with the results given from the load flow and short circuit analysis. The results indicate positive impacts on the system interconnected with PVDG such as improving voltage profile, reducing power losses, releasing transmission and distribution grid capacity. It also shows that optimal locations and sizes of DGs are needed to minimize the system’s power losses. On the other hand, it shows that PVDG interconnection to the system can cause reverse power flow at improper DG size and location and increases short circuit level.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Sanjay Jain ◽  
Ganga Agnihotri ◽  
Shilpa Kalambe ◽  
Renuka Kamdar

This paper intends to enumerate the impact of distributed generation (DG) on distribution system in terms of active as well as reactive power loss reduction and improved voltage stability. The novelty of the method proposed in this paper is the simple and effective way of sizing and siting of DG in a distribution system by using two-port Z-bus parameters. The validity of the method is verified by comparing the results with already published methods. Comparative study presented has shown that the proposed method leads existing methods in terms of its simplicity, undemanding calculation procedures, and less computational efforts and so does the time. The method is implemented on IEEE 69-bus test radial distribution system and results show significant reduction in distribution power losses with improved voltage profile of the system. Simulation is carried out in MATLAB environment for execution of the proposed algorithm.


2018 ◽  
Vol 1 (1) ◽  

Renewable energy sources are available for practical usage at almost every location in the world. Irrigation of the agricultural areas requires energy, where renewable energy sources are very appropriate for such usage. Very often agricultural areas are located on isolated and remote areas, where sometimes electric energy from electric grid is not available or it is too expensive. In this situation, renewable energy sources are very suitable for water pumping. This paper will present a real case study of possible application of renewable energy sources for water pumping at a family agricultural farm in Selnica Podravska, located in northern part of Croatia. There is a plan to build an irrigation system for Dwarf French bean (lat. Phaseolus vulgaris L.) for an area of 1978m2 . Available water resource is ground water. Particular renewable energy sources will be considered, as well as their potential for production of electric energy for water pumping.


Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8240
Author(s):  
Wadim Strielkowski ◽  
Lubomír Civín ◽  
Elena Tarkhanova ◽  
Manuela Tvaronavičienė ◽  
Yelena Petrenko

The electrical power sector plays an important role in the economic growth and development of every country around the world. Total global demand for electric energy is growing both in developed and developing economies. The commitment to the decarbonization of economies, which would mean replacing fossil fuels with renewable energy sources (RES) as well as the electrification of transport and heating as a means to tackle global warming and dangerous climate change, would lead to a surge in electricity consumption worldwide. Hence, it appears reasonable that the electric power sector should embed the principles of sustainable development into its functioning and operation. In addition, events such as the recent European gas crisis that have emerged as a result of the massive deployment of renewables need to be studied and prevented. This review aims at assessing the role of the renewable energy in the sustainable development of the electrical power sector, focusing on the energy providers and consumers represented both by businesses and households that are gradually becoming prosumers on the market of electric energy. Furthermore, it also focuses on the impact of renewables on the utility side and their benefits for the grid. In addition, it identifies the major factors of the sustainable development of the electrical power sector.


2020 ◽  
Vol 18 (5) ◽  
pp. 1209-1222 ◽  
Author(s):  
Saheed Lekan Gbadamosi ◽  
Nnamdi I. Nwulu

Purpose The purpose of this study is to address the efficiency of power losses representation while still reducing the computational burden of an optimal power flow (OPF) model in transmission expansion planning (TEP) studies. Design/methodology/approach A modified TEP model is formulated with inclusions of linearized approximation of power losses for a large-scale power system with renewable energy sources. The multi-objectives function determines the effect of transmission line losses on the optimal power generation dispatch in the power system with and without inclusion of renewable energy sources with emphasis on minimizing the investment and operation costs, emission and the power losses. Findings This study investigates the impact of renewable energy sources on system operating characteristics such as transmission power losses and voltage profile. Sensitivity analysis of the performance for the developed deterministic quadratic programming models was analyzed based on optimal generated power and losses on the system. Research limitations/implications In the future, a comparison of the alternating current OPF and direct current (DC) OPF models based on the proposed mathematical formulations can be carried out to determine the efficiency and reduction of computation process of the two models. Practical implications This paper proposed an accurate way of computing transmission losses in DC OPF for a TEP context with a view of achieving a minimal computation time. Originality/value This paper addresses the following objectives: develop a modified DC OPF with a linearized approximation of power losses in TEP problem with large integration of RES. Investigate the impact of RES on system operating characteristics such as transmission power losses and voltage profile.


2020 ◽  
Vol 12 (14) ◽  
pp. 5634
Author(s):  
Agnieszka Czaplicka-Kotas ◽  
Joanna Kulczycka ◽  
Natalia Iwaszczuk

One of the priority lines of action in Poland is to increase energy production from renewable energy sources (RESs). Based on the “Poland’s national energy and climate plan for the years 2021–2030”, Poland aims to achieve 21%–23% of RES share in gross final energy consumption by 2030. While coal is still the most important source of energy, new technological and organisational solutions for increasing RESs are being tested and implemented. Therefore, the creation of energy clusters based on the idea of urban and industrial symbiosis was first proposed by the Ministry of Energy in 2016. To date, there are 66 clusters in different regions in Poland, but only a few of them are active and innovative. One of them is located in the city of Zakopane, a mountain resort, which attracts about 3 million tourists annually and has developed the wide-ranging use of geothermal sources for energy supply and recreation. The paper aims to analyse the impact of the creation of energy clusters on the city’s development, including economic, social, and environmental aspects. The “willingness to pay” (WTP) method was used to calculate the impact of air pollution on Zakopane and to compare it with the Polish average to estimate the significance of the transformation to RESs in this tourist city. The results from the studies are as follows: health cost per capita in Zakopane is between 252.07 and 921.30 euro. The investigations presented can be the basis for recommendations in strategic documents in the field of regional development and environmental protection, especially on the use and promotion of urban symbiosis for increasing use of RESs.


Sign in / Sign up

Export Citation Format

Share Document