scholarly journals Finite Element Analysis for The Response of URM Walls Supporting RC Slab

2018 ◽  
Vol 7 (4.20) ◽  
pp. 259
Author(s):  
Ammar Rafid Ahmed ◽  
Alaa H. Al-Zuhairi

The aim for this research is to investigate the effect of inclusion of crack incidence into the 2D numerical model of the masonry units and bonding mortar on the behavior of unreinforced masonry walls supporting a loaded reinforced concrete slab. The finite element method was implemented for the modeling and analysis of unreinforced masonry walls. In this paper, ABAQUS, FE software with implicit solver was used to model and analyze unreinforced masonry walls which are subjected to a vertical load. Detailed Micro Modeling technique was used to model the masonry units, mortar and unit-mortar interface separately. It was found that considering potential pure tensional cracks located vertically in the middle of the mortar and units shows an increase in masonry strength of about 10% than the strength calculated using the procedure recommended by the Masonry Society Joint Committee in the building code.  

Author(s):  
Marco Miglietta ◽  
Nicolò Damiani ◽  
Gabriele Guerrini ◽  
Francesco Graziotti

AbstractTwo full-scale building specimens were tested on the shake-table at the EUCENTRE Foundation laboratories in Pavia (Italy), to assess the effectiveness of an innovative timber retrofit solution, within a comprehensive research campaign on the seismic vulnerability of existing Dutch unreinforced masonry structures. The buildings represented the end-unit of a two-storey terraced house typical of the North-Eastern Netherlands, a region affected by induced seismicity over the last few decades. This building typology is particularly vulnerable to earthquake excitation due to lack of seismic details and irregular distribution of large openings in masonry walls. Both specimens were built with the same geometry. Their structural system consisted of cavity walls, with interior load-bearing calcium-silicate leaf and exterior clay veneer, and included a first-floor reinforced concrete slab, a second-floor timber framing, and a roof timber structure supported by masonry gables. A timber retrofit was designed and installed inside the second specimen, providing an innovative sustainable, light-weight, reversible, and cost-effective technique, which could be extensively applied to actual buildings. Timber frames were connected to the interior surface of the masonry walls and completed by oriented strands boards nailed to them. The second-floor timber diaphragm was stiffened and strengthened by a layer of oriented-strand boards, nailed to the existing joists and to additional blocking elements through the existing planks. These interventions resulted also in improved wall-to-diaphragm connections with the inner leaf at both floors, while steel ties were added between the cavity-wall leaves. The application of the retrofit system favored a global response of the building with increased lateral capacities of the masonry walls. This paper describes in detail the bare and retrofitted specimens, compares the experimental results obtained through similar incremental dynamic shake-table test protocols up to near-collapse conditions, and identifies damage states and damage limits associated with displacements and deformations.


Author(s):  
Ane de Boer ◽  
Max A. N. Hendriks ◽  
Eva O. L. Lantsoght

<p>The Dutch Ministry of Infrastructure and the Environment is concerned with the safety of existing infrastructure and expected re-analysis of a large number of bridges and viaducts. Nonlinear finite element analysis can provide a tool to assess safety; a more realistic estimation of the existing safety can be obtained.</p><p>Dutch Guidelines, based on scientific research, general consensus among peers, and a long-term experience with nonlinear analysis, allow for a reduction of model and user factors and improve the robustness of nonlinear finite element analyses.</p><p>The 2017 version of the guidelines can be used for the finite element analysis of basic concrete structural elements like beams, girders and slabs, reinforced or prestressed. Existing structures, like box-girder structures, culverts and bridge decks with prestressed girders in composite structures can be analysed.</p><p>The guidelines have been developed with a two-fold purpose. First, to advice analysts on nonlinear finite element analysis of reinforced and pre-stressed concrete structures. Second, to explain the choices made and to educate analysts, related to the responsibility of limiting model uncertainty.</p><p>This paper contains an overview of the latest version of the guideline and its latest validation extensions. Most important impact is the extended operational lifetime of an existing reinforced concrete slab structure.</p>


1993 ◽  
Vol 20 (4) ◽  
pp. 587-601 ◽  
Author(s):  
Pierre Léger ◽  
Patrick Paultre

Microcomputer finite element analysis of reinforced concrete slab systems can now be routinely performed to produce realistic numerical simulation of three-dimensional structural behaviour. However, an efficient use of this approach requires an automated integration of design and analysis procedures. Guidelines for proper finite element modelling of slab systems are first presented along with simple post-processing algorithms to perform automatically the design or verifications from the analytical results. Numerical applications on simple slab systems subjected to uniform and concentrated loads are then used to illustrate the relative performance between finite element analyses and the equivalent frame method. Key words: microcomputer, reinforced concrete slab, finite element method, structural design.


2014 ◽  
Vol 1049-1050 ◽  
pp. 294-299
Author(s):  
Long Min Jiang ◽  
Ai Bo He ◽  
Yan Huang

High performance ferrocement laminate (HPFL) reinforcement method is used in this paper to make a finite element analysis on mechanical properties of five reinforced slab-column members. The analysis shows that the bearing capacity of reinforced slab columns and rigidity of midspan slab band have been improved accordingly. Furthermore, with different layout types (field type, groined type and, cross type) of steel mesh in reinforced layer, reinforcement effect and mechanical behavior of reinforced columns can be different. On the premise that punching shear resistance of original columns is strong enough, cross-type reinforcement is the best bending resistance reinforcement pattern of the best reinforcement effect with field-type reinforcement as the second. A reasonable selection of reinforcement pattern shall be made on the basis of the structure’s own mechanical characteristics while a reasonable reinforcement pattern can both ensure the effect of reinforced columns and cut the costs. Conclusions of the paper are supposed to provide some references for reinforcement design in practical engineering.


Sign in / Sign up

Export Citation Format

Share Document