scholarly journals Range Performance Modelling of Thermal Imaging System based on Single Parameter Characterised by Ambient Temperature and Relative Humidity

2018 ◽  
Vol 68 (5) ◽  
pp. 480-486
Author(s):  
Sudhir Khare ◽  
Manvendra Singh ◽  
Brajesh Kumar Kaushik

Range performance of a thermal imaging system is characterised by the prevailing atmospheric condition present at that time. There are two dominant parameters that limit the range performance of any thermal imaging systems i.e. ambient temperature and relative humidity. In the present work, comparative study of acquisition range performance of thermal imaging system operating in LWIR and MWIR spectral bands has been presented as a function of absolute humidity (AH) which is responsible for attenuation of IR radiation due to water vapour molecules present in path length. Presentation of acquisition range as function of AH leads to a single range performance table/graph for thermal imaging system under consideration for predefined visibility (V), target size, ambient temperature (T), target to background temperature difference (ΔT) and relative humidity (RH). This table/graph can be used to predict detection, recognition and identification ranges for any set of combination of air temperature (T) and relative humidity (RH). The approach presented in this paper is versatile and has been illustrated through comparative performance analysis of LWIR and MWIR thermal imaging systems based on 640X512 staring focal plane array (FPA) having identical design parameters in terms of resolution (IFOV). It has been shown that MWIR performance is superior to LWIR beyond a crossover value of AH(T) even though MRTD of MWIR sensor is inferior to that of LWIR sensor at all spatial frequencies. Study has been carried out both for clear atmosphere and hazy conditions.

2019 ◽  
Vol 29 (4) ◽  
pp. 106
Author(s):  
Basaad Hadi Hamza

Modern sensor systems have complex sensor assemblies with performance depending on variety of factors. An algorithm presented in this work to provide accurate image rendering in the optical spectral ranges of IR imaging systems. From the images output notice that in long wavelength bandwidth of IR (8-12) µm the image was more clarity without noise. This mean S/N ratio and the Efficiency of detector is bigger than band (1-3) µm. Recommend that this method can be used to improve the performance of the thermal detector which uses in thermal imaging system in any package of wavelength. This algorithm can be store as a code in the cart storage of IR imaging system.


2005 ◽  
Vol 38 (1) ◽  
pp. 115-118 ◽  
Author(s):  
Klaus Gottschalk ◽  
Sabine Geyer ◽  
Hans-Jürgen Hellebrand

2015 ◽  
Vol 24 (4) ◽  
pp. 264-269
Author(s):  
Byung Mok Sung ◽  
Dong Geon Jung ◽  
Soon Jae Bang ◽  
Sun Min Baek ◽  
Seong Ho Kong

2021 ◽  
Vol 310 ◽  
pp. 01002
Author(s):  
Dmitriy Otkupman ◽  
Sergey Bezdidko ◽  
Victoria Ostashenkova

The efficiency of using Zernike moments when working with digital images obtained in the infrared region of the spectrum is considered to improve the accuracy and speed of an autonomous thermal imaging system. The theoretical justification of the choice of Zernike moments for solving computer (machine) vision problems and the choice of a suitable threshold binarization method is given. In order to verify the adequacy and expediency of using the chosen method, practical studies were conducted on the use of Zernike methods for distorting various thermal images in shades of gray.


2021 ◽  
Vol 36 (6) ◽  
pp. 886-895
Author(s):  
Hai-lin ZHONG ◽  
◽  
Yue-tao YANG ◽  
Xin WANG ◽  
Feng CAO ◽  
...  

2018 ◽  
pp. 1109-1132 ◽  
Author(s):  
Nilanjan Dey ◽  
Amira S. Ashour ◽  
Afnan S. Althoupety

Thermal imaging is a non-destructive, non-contact and rapid system. It reports temperature through measuring infrared radiation emanated by an object/ material surface. Automated thermal imaging system involves thermal camera equipped with infrared detectors, signal processing unit and image acquisition system supported by computer. It is elaborated in wide domains applications. Extensive focus is directed to the thermal imaging in the medical domain especially breast cancer detection. This chapter provided the main concept and the different applications of thermal imaging. It explores and analyses several works in the light of studding the thermograph. It is an effective screening tool for breast cancer prediction. Studies justify that thermography can be considered a complementary tool to detect breast diseases. The current chapter reviews many usages and limitations of thermography in biomedical field. Extensive recommendations for future directions are summarized to provide a structured vision of breast thermography.


2018 ◽  
Vol 38 (12) ◽  
pp. 1231001
Author(s):  
付秀华 Fu Xiuhua ◽  
刘文奇 Liu Wenqi ◽  
尹士平 Yin Shiping ◽  
刘克武 Liu Kewu ◽  
刘冬梅 Liu Dongmei

2020 ◽  
Vol 97 (10) ◽  
pp. 3887-3891
Author(s):  
Ronald Soong ◽  
Amy Jenne ◽  
Rajshree Ghosh Biswas ◽  
Antonio Adamo ◽  
Andre Simpson

Sign in / Sign up

Export Citation Format

Share Document