scholarly journals Corynebacterium striatum Cardiac Device-Related Infective Endocarditis: The First Case Report in a Patient With a Cardiac Resynchronization Therapy Defibrillator Device and Review of the Literature

2021 ◽  
Vol 12 (2) ◽  
pp. 61-64
Author(s):  
Luisa Serpa Pinto ◽  
Andre Dias Frias ◽  
Margarida Franca
2021 ◽  
Vol 73 (1) ◽  
Author(s):  
Vanita Arora ◽  
Francesco Zanon ◽  
Viveka Kumar ◽  
Vivek Kumar ◽  
Pawan Suri

Abstract Background As per the literature, patients with intraventricular conduction delay (IVCD) do not respond well to cardiac resynchronization therapy (CRT) alone. They need advanced technological approach and out of the box thinking for a good response. Case Ours is a case of ischemic cardiomyopathy with wide QRS-IVCD, a non-responder to CRT. While planning for replacement of the device for early replacement indicator (ERI), we decided to do His-optimized CRT/left bundle optimized CRT (HOT-CRT/LOT-CRT) for the patient. Conclusion The challenges we faced with the present available hardware paved a way for insisting on the limitation of the available lumenless lead to penetrate calcified the septum and importance of the pre-procedure evaluation of intraventricular septum (IVS) for calcification by more than just echocardiography.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
E Jedrzejczyk-Patej ◽  
M Mazurek ◽  
W Kowalska ◽  
M Bugajski ◽  
A Konieczny-Kozielska ◽  
...  

Abstract Background Over a quarter of all cardiac resynchronization therapy (CRT) implants are upgrades from previous devices, mainly from implantable cardioverter-defibrillator (ICD). In comparison to CRT with defibrillator (CRT-D) de novo implantation, upgrade from ICD to CRT-D carries higher risk of complications. Limited number of studies evaluated predictors of death in patients undergoing upgrade from ICD to CRT-D. Aim To determine mortality predictors and outcome in patients undergoing upgrade from ICD to CRT-D in comparison to subjects with CRT-D de novo implantation. Methods Study population consisted of 595 consecutive patients with CRT-D implanted between 2002 and 2015 in tertiary care university hospital, in a densely inhabited, urban region of Poland (480 subjects [84.3%] with CRT-D de novo implantation; 115 patients [15.7%] upgraded from ICD to CRT-D). Results The median follow-up was 1692 days (range: 457–3067). All-cause mortality in patients upgraded from ICD was significantly higher than in subjects with CRT-D implanted de novo (43.5% vs. 35.5%, P=0.045). On multivariable regression analysis, left ventricular end-systolic diameter (HR 1.07, 95% CI 1.02–1.11, P=0.002), creatinine level at baseline (HR 1.01, 95% CI 1.00–1.02, P=0.01), NYHA IV class at baseline (HR 2.36, 95% CI 1.00–5.53, P=0.049) and cardiac device-related infective endocarditis (CDRIE) during follow up (HR 2.42, 95% CI 1.02–5.75, P=0.046) were identified as independent predictors of higher mortality in patients with CRT-D upgraded from ICD. Conclusions Mortality rate in patients upgraded from ICD is higher in comparison to CRT-D de novo implanted subjects, and reaches almost 45% within 4.5 years. Left ventricular dimensions, creatinine level, high NYHA class at baseline and infective endocarditis during follow up are independent mortality predictors in patients with CRT-D upgraded from ICD.


Sign in / Sign up

Export Citation Format

Share Document