scholarly journals Computational Fluid Dynamics and Experimental Studies of a New Mixing Element in a Static Mixer as a Heat Exchanger

2015 ◽  
Vol 36 (1) ◽  
pp. 59-72 ◽  
Author(s):  
Maciej Konopacki ◽  
Marian Kordas ◽  
Karol Fijałkowski ◽  
Rafał Rakoczy

Abstract The main aim of this work is to study the thermal efficiency of a new type of a static mixer and to analyse the flow and temperature patterns and heat transfer efficiency. The measurements were carried out for the static mixer equipped with a new mixing insert. The heat transfer enhancement was determined by measuring the temperature profiles on each side of the heating pipe as well as the temperature field inside the static mixer. All experiments were carried out with varying operating parameters for four liquids: water, glycerol, transformer oil and an aqueous solution of molasses. Numerical CFD simulations were carried out using the two-equation turbulence k-ω model, provided by ANSYS Workbench 14.5 software. The proposed CFD model was validated by comparing the predicted numerical results against experimental thermal database obtained from the investigations. Local and global convective heat transfer coefficients and Nusselt numbers were detrmined. The relationship between heat transfer process and hydrodynamics in the static mixer was also presented. Moreover, a comparison of the thermal performance between the tested static mixer and a conventional empty tube was carried out. The relative enhancement of heat transfer was characterised by the rate of relative heat transfer intensification.

2018 ◽  
Vol 240 ◽  
pp. 05012
Author(s):  
Piotr Kopeć ◽  
Beata Niezgoda-Żelasko

This paper analyses the mixed convection process in a fanless evaporator of an air heat pump. The text of the paper shows the authors’ experimental studies results of the temperature distribution and the local values of heat transfer coefficients on the outer surface of vertical tubes with longitudinal fins for the case of mixed convection and fins of a specific shape of their cross-section (prismatic, wavy fins). The experimental studies include the air velocities wa=2,3 m/s and the temperature differences between air and the refrigerant inside the heat exchanger tubes which is ΔT=24-40K. The results obtained were used for verification of CFD modeling of the heat transfer process for the discussed case of heat transfer and the geometry of the finned surface. The numerical analysis was performed for: the temperature distribution along the fin height, the tube perimeter and height, the distribution of local heat transfer coefficients on the finned tube perimeter and along its height. The simulated calculations were used to verify the method of determination of fin efficiency.


Author(s):  
Aleksandr S. MYAKOCHIN ◽  
Petr V. NIKITIN ◽  
Sergey Yu. POBEREZHSKIY ◽  
Anna A. SHKURATENKO

The paper presents a method, tools and a newly developed algorithm for experimentally determining heat transfer coefficients in organic liquids and solutions. This work is made relevant by the problem of development of a new generation of aerospace technology. In this connection, improvements have been made to the pulse method of determining heat transfer coefficients that is based on the use of a micron-thick film sensor. The measurement setup was modified. A math model was constructed for the measuring sensor. Algorithms were developed for conducting the experiment and processing measurement results to determine heat transfer coefficients. Experimental uncertainties were analyzed. The paper provides results of experimental studies on certain organic liquids. The authors believe that the material presented in the paper will find application in research conducted at research institutions, engineering offices and universities, among researches, postgraduates and students. Key words: thermal and physical characteristics, organic liquids and their solutions, film-type electrical resistor, thin-film temperature sensor, voltage pulse, resistance thermometer, irregular heat transfer regime.


2005 ◽  
Vol 128 (6) ◽  
pp. 557-563 ◽  
Author(s):  
Paul L. Sears ◽  
Libing Yang

Heat transfer coefficients were measured for a solution of surfactant drag-reducing additive in the entrance region of a uniformly heated horizontal cylindrical pipe with Reynolds numbers from 25,000 to 140,000 and temperatures from 30to70°C. In the absence of circumferential buoyancy effects, the measured Nusselt numbers were found to be in good agreement with theoretical results for laminar flow. Buoyancy effects, manifested as substantially higher Nusselt numbers, were seen in experiments carried out at high heat flux.


1983 ◽  
Vol 105 (3) ◽  
pp. 433-439 ◽  
Author(s):  
N. Seki ◽  
S. Fukusako ◽  
A. Yamaguchi

Experimental measurements are presented for free convective heat transfer across a parallelogrammic enclosure with the various tilt angles of parallel upper and lower walls insulated. The experiments covered a range of Rayleigh numbers between 3.4 × 104 and 8.6 × 107, and Prandtl numbers between 0.70 and 480. Those also covered the tilt angles of the parallel insulated walls with respect to the horizontal, φ, of 0, ±25, ±45, ±60, and ±70 deg under an aspect ratio of H/W = 1.44. The fluids used were air, transformer oil, and water. It was found that the heat transfer coefficients for φ = −70 deg were decreased to be about 1/18 times those for φ = 0 deg. Experimental results are given as plots of the Nusselt number versus the Rayleigh number. A correlation equation is given for the Nusselt number, Nu, as a function of φ, Pr, and Ra.


Author(s):  
G. Qureshi ◽  
M. H. Nguyen ◽  
N. R. Saad ◽  
R. N. Tadros

To optimise the turbine disc weight and coolant flow requirements, the aspect of improving thermal analysis was investigated. As a consequence, an experimental investigation was undertaken to measure the rates of convective heat transfer. The constant temperature steady state technique was used to determine the local and average heat transfer coefficients on the sides of rotating discs. The effects of coolant flow rates, CW (3000 ≤ CW ≤ 18600) with two types of cavity in-flow conditions and of the rotational speeds, Reθ (from 4×105 to 1.86×106) on the disc heat transfer were studied and correlations developed. For a rotating disc in confined cavities with superimposed coolant flows, Nusselt numbers were found to be higher than those for the free rotating disc without confinement.


Author(s):  
Ansar Ali SK ◽  
Pardeep Kumar ◽  
Sandeep Kumar

The aim of this experimental study is to determine the heat transfer coefficients in laminar regime of mechanically agitated vessel for Newtonian (water) and non-Newtonian fluids, i.e. CMC (carboxy methyl cellulose) solutions in mechanically agitated vessel. It is found that Dean number and Prandtl number play an important role with Nusselt number while determining heat transfer coefficients. Modified Wilson plot is used to find heat transfer. The effect of friction factor on Reynolds number is also studied. The laminar flow heat transfer results have been successfully correlated in the following form with 15% standard deviation and this equation is suitable for the correlation for both Newtonian and non-Newtonian fluids to find heat transfer coefficients in helical coils in mechanically agitated stirred vessel.


Author(s):  
Ting Wang ◽  
Mingjie Lin ◽  
Ronald S. Bunker

Experimental studies on heat transfer and flow structure in confined impingement jets were performed. The objective of this study was to investigate the detailed heat transfer coefficient distribution on the jet impingement target surface and flow structure in the confined cavity. The distribution of heat transfer coefficients on the target surface was obtained by employing the transient liquid crystal method coupled with a 3-D inverse transient conduction scheme under Reynolds number ranging from 1039 to 5175. The results show that the average heat transfer coefficients increased linearly with the Reynolds number as Nu = 0.00304 Pr0.42Re. The effects of cross flow on heat transfer were investigated. The flow structure were analyzed to gain insight into convective heat transfer behavior.


2014 ◽  
Vol 136 (8) ◽  
Author(s):  
Yutaka Ito ◽  
Naoya Inokura ◽  
Takao Nagasaki

A light and compact heat exchange system was realized using two air-to-refrigerant airfoil heat exchangers and a recirculated heat transport refrigerant. Its heat transfer performance was experimentally investigated. Carbon dioxide or water was used as a refrigerant up to a pressure of 30 MPa. Heat transfer coefficients on the outer air-contact and inner refrigerant-contact surfaces were calculated using an inverse heat transfer method. Correlations were developed for the Nusselt numbers of carbon dioxide and water on the inner refrigerant-contact surface. Furthermore, we proposed a method to evaluate a correction factor corresponding to the thermal resistance of the airfoil heat exchanger.


1995 ◽  
Vol 117 (2) ◽  
pp. 309-315 ◽  
Author(s):  
B. L. Owsenek ◽  
J. Seyed-Yagoobi ◽  
R. H. Page

Corona wind enhancement of free convection was investigated with the needle-plate geometry in air. High voltage was applied to a needle suspended above a heated plate, and heat transfer coefficients were computed by measuring the plate surface temperature distribution with an infrared camera. Local heat transfer coefficients greater than 65 W/m2 K were measured, an enhancement of more than 25:1 over natural convection. The enhancement extended over a significant area, often reaching beyond the 30 cm measurement radius. At high power levels, Joule heating significantly reduced the effective impingement point heat transfer coefficient. The corona wind was found to be more efficient with positive potential than with negative. The heat transfer efficiency was optimized with respect to electrode height and applied voltage. The needle-plate heat transfer effectiveness improved rapidly with increasing height, and became relatively insensitive to height above a threshold value of about 5 cm.


Author(s):  
Reby Roy ◽  
B. V. S. S. S. Prasad ◽  
S. Srinivasa Murthy

The conjugate heat transfer in a stationary cylindrical cavity with a rotating disk and fluid through-flow is analysed at various rotational speeds ranging from 10000 to 50000 rpm by using a finite volume commercial code. The numerical model and code are validated for a problem, which involves rotation and fluid through-flow. A reduction of the thermal boundary layer thickness and increase in the heat transfer coefficients are observed with increase in the rotational speed. Marked differences are noticed between the Nusselt numbers obtained from the conjugate and constant temperature analyses.


Sign in / Sign up

Export Citation Format

Share Document