scholarly journals Ultrasonography: a method used for pregnancy imaging of the fire salamander (Salamandra salamandra)

2016 ◽  
Vol 19 (4) ◽  
pp. 715-722
Author(s):  
A. Najbar ◽  
Z. Kiełbowicz ◽  
J. Szymczak ◽  
M. Ogielska

Abstract Ultrasound imaging has more frequently been used in veterinary medicine of amphibians and reptiles. In this study, we have verified the usefulness of ultrasound imaging in pregnancy determination of the fire salamander Salamandra salamandra. We have also undertaken to estimate the number of larvae and their developmental stage directly in the oviducts. Three gravid females from Lower Silesia (southern Poland) were examined. Due to the small size of the scanned animals, and the particular arrangement of embryos in the oviducts and ultrasound beams dispersal, the method proved to be inaccurate. Therefore, the minimum number of well-visualized larvae was determined. The maximum number of larvae was established on the basis of the visible fragments of embryos. After birth, we found that the number of larvae born was included in the „min-max” range in only one case. In the remaining two salamanders the number of larvae was higher than estimated in 3 to 7 individuals. The results showed that ultrasound imaging allows the minimum number of larvae in salamander; oviducts to be specified. However, total length measurements were possible only for single and clearly visible embryos.

2020 ◽  
pp. 73-75
Author(s):  
B.M. Bazrov ◽  
T.M. Gaynutdinov

The selection of technological bases is considered before the choice of the type of billet and the development of the route of the technological process. A technique is proposed for selecting the minimum number of sets of technological bases according to the criterion of equality in the cost price of manufacturing the part according to the principle of unity and combination of bases at this stage. Keywords: part, surface, coordinating size, accuracy, design and technological base, labor input, cost price. [email protected]


Author(s):  
Y. F. Zhang ◽  
A. Y. C. Nee ◽  
J. Y. H. Fuh

Abstract One of the most difficult tasks in automated process planning is the determination of operation sequencing. This paper describes a hybrid approach for identifying the optimal operation sequence of machining prismatic parts on a three-axis milling machining centre. In the proposed methodology, the operation sequencing is carried out in two levels of planning: set-up planning and operation planning. Various constraints on the precedence relationships between features are identified and rules and heuristics are created. Based on the precedence relationships between features, an optimization method is developed to find the optimal plan(s) with minimum number of set-ups in which the conflict between the feature precedence relationships and set-up sequence is avoided. For each set-up, an optimal feature machining sequence with minimum number of tool changes is also determined using a developed algorithm. The proposed system is still under development and the hybrid approach is partially implemented. An example is provided to demonstrate this approach.


1998 ◽  
Vol 6 (A) ◽  
pp. A163-A170 ◽  
Author(s):  
B. Barabás

The testing and adjusting procedure of near infrared (NIR) spectrophotometers is based on the measurement of some standards and, if necessary, on the adjustment of the constants in the calibration equation. For this work some use few standards, whereas others use 20 or more. This work was aimed to determine the range of error compensation and the minimum number of standards required. The experiments were applied to wheat protein measurement using two scanning spectrophotometers. The errors in the NIR measurements were characterised as bias, skew, error derived from skew ( Eskew) and standard error of difference corrected for bias and skew ( SEDc) parameters and supposed that errors derived from the change in the wavelength or reflectance of the instrument. The confidence intervals of bias and skew, derived from duplicate measurements of various numbers of wheat standards, were used to determine the minimum number of standards required. The range of error compensation was defined with those bias values, where SEDc was smaller, than an acceptable limit. The range of compensation corresponded to a bias value of ± 8 g kg−1 for wheat protein measurements. The detection of error of measurements required 4 wheat standards. The elimination of errors of bias and skew required 9 standards within the above limits. The developed procedure was tested in case of real instrument error. Diminishing a bias from 5.2 g kg−1 to 0.7 g kg−1 and the root mean square difference ( RMSD) to an acceptable level required the use of 9 standards, similar to the model experiment. The simplicity and rapidity (about 10 min) of the procedure enabled the routine test of NIR instruments. The range of error compensation and the number of standards referred to wheat protein. The simple modelling procedure proved also suitable for the determination of these values for other components and under other measuring conditions.


2020 ◽  
Vol 23 (1) ◽  
pp. 130-137
Author(s):  
S. Jazi ◽  
A. Mokhtari ◽  
A. Ebrahimi Kahrizsangi

Given the high incidence of keratoconjunctivitis in Iran (approximately 3.6–53.9%) and low efficiency of clinical diagnostic measures, application of laboratory tests for detection of different keratoconjunctivitis/conjunctivitis causes and determination of their accurate prevalence is essential. In this research, conjunctival samples were collected from 100 patients with keratoconjunctivitis signs referred to an eye hospital of Iran. After DNA extraction, PCR was carried out for detection of Chlamydia psittaci and Chlamydia felis. PCR positive products were further subjected for DNA sequencing. In this study, one sample was Chlamydia psittaci positive and none was positive for Chlamydia felis. There wasn’t a statistically significant relationship between working in the field of veterinary medicine or keeping a pet and Chlamydia psittaci prevalence (P>0.05). This study showed a low rate of chlamydial keratoconjunctivitis and therefore further studies for detection of other causes are necessary.


Author(s):  
J. E. H. Stafford

A versatile radioimmunoassay for serum oestriol in pregnancy has been developed which requires 10 μ| of serum (for total) or 50 μ| (for unconjugated). Selection of the optimum conditions for the hydrolysis of serum oestriol conjugates, the isolation of free oestriol, the displacement of tritiated oestriol by cold oestriol and the separation of the free and bound fractions is described. Total oestriol levels doubled between weeks 34 and 38 of normal pregnancy, very little change occurring in the mean level after the 38th week of gestation. In a random series of pregnancy sera there was a significant correlation between total and unconjugated oestriol.


2016 ◽  
Vol 13 (3) ◽  
pp. 126
Author(s):  
Jayanta Chakraborty ◽  
Semanti Chakraborty ◽  
Ankan Bandopadhay

Sign in / Sign up

Export Citation Format

Share Document