Test Method for Compressive Strength of Architectural Cast Stone

2019 ◽  
Author(s):  
TAPPI Journal ◽  
2009 ◽  
Vol 8 (6) ◽  
pp. 24-28
Author(s):  
CORY JAY WILSON ◽  
BENJAMIN FRANK

TAPPI test T811 is the specified method to ascertain ECT relative to box manufacturer’s certification compliance of corrugated fiberboard under Rule 41/ Alternate Item 222. T811 test sample heights were derived from typical board constructions at the time of the test method’s initial development. New, smaller flute sizes have since been developed, and the use of lighter weight boards has become more common. The T811 test method includes sample specifications for typical A-flute, B-flute, and C-flute singlewall (and doublewall and triplewall) structures, but not for newer thinner E-flute or F-flute structures. This research explores the relationship of ECT sample height to measured compressive load, in an effort to determine valid E-flute and F-flute ECT sample heights for use with the T811 method. Through this process, it identifies challenges present in our use of current ECT test methods as a measure of intrinsic compressive strength for smaller flute structures. The data does not support the use of TAPPI T 811 for ECT measurement for E and F flute structures, and demonstrates inconsistencies with current height specifi-cations for some lightweight B flute.


Materials ◽  
2020 ◽  
Vol 13 (8) ◽  
pp. 1898
Author(s):  
Marek Urbański

A new type of HFRP hybrid bars (hybrid fiber reinforced polymer) was introduced to increase the rigidity of FRP reinforcement, which was a basic drawback of the FRP bars used so far. Compared to the BFRP (basalt fiber reinforced polymer) bars, modification has been introduced in HFRP bars consisting of swapping basalt fibers with carbon fibers. One of the most important mechanical properties of FRP bars is compressive strength, which determines the scope of reinforcement in compressed reinforced concrete elements (e.g., column). The compression properties of FRP bars are currently ignored in the standards (ACI, CSA). The article presents compression properties for HFRP bars based on the developed compression test method. Thirty HFRP bars were tested for comparison with previously tested BFRP bars. All bars had a nominal diameter of 8 mm and their nonanchored (free) length varied from 50 to 220 mm. Test results showed that the ultimate compressive strength of nonbuckled HFRP bars as a result of axial compression is about 46% of the ultimate strength. In addition, the modulus of elasticity under compression does not change significantly compared to the modulus of elasticity under tension. A linear correlation of buckling load strength was proposed depending on the free length of HFRP bars.


2019 ◽  
Vol 16 (33) ◽  
pp. 823-840
Author(s):  
M. K. TARABAI ◽  
S. G. de AZEVEDO

This paper discusses a possible solution regarding the final disposal of sludge from Sanitary Sewage Treatment Stations (ET), aiming at environmental preservation. The solid waste generated after the wastewater treatment processes is highly contaminating and detrimental to the area in which it is deposited. Given this, the use of sludge with the application of reuse techniques becomes pertinent, both from the economic point of view and from the ecological point of view. By replacing the use of aggregates from mineral deposits, the main clay raw material in the manufacture of ceramic products (Vieira, 2000), by the treated sludge of WWTP we will save on the sources of granular materials. Aiming its reintegration to the production cycle through the introduction of sludge as raw material incorporated in the ceramic mass in the manufacture of hollow bricks, the viability of use was verified through performance analysis, compared to the control brick made of pottery, without the addition of sludge. Specimens were prepared with three types of samples: 90% clay and 10% sludge; 80% clay and 20% sludge; 70% clay and 30% sludge. Mass loss, water absorption index and compressive strength tests were performed. As for the tests, the specimens with 10% and 20% of sludge were the ones that had better adaptation to the technical requirements, but because it is a larger volume of the residue for the application of reuse techniques, the brick with 20% sludge dosage. is the most suitable. NBR7.171, November 1992: Ceramic Block for masonry; Specification NBR 6.461, June 1983: Masonry Ceramic Block - Compressive Strength Check: Test Method; NBR 8.947, November 1992: Ceramic Tile- Determination of Mass and Water Absorption: Test Method. As for the tests, the specimen with 20% of sludge was the one that had the best adaptation to technical and environmental requirements. The present article approaches a possible solution regarding the destination of the sludge coming from Sanitary Sewage Treatment Stations, aiming at environmental preservation. Aiming at its reintegration into the productive cycle through applications of reuse techniques, the sludge became raw material when the ceramic mass was incorporated into the brick fabrication. Three types of samples were elaborated: 90% of clay and 10% of mud; 80% clay and 20% sludge; 70% clay and 30% sludge. As for the tests, the test specimen with 20% of sludge was the one that had more adequacy to the technical and environmental requirements.


Sign in / Sign up

Export Citation Format

Share Document