scholarly journals Analysis of the hydraulic connection of the Plitvica stream and the groundwater of the Varaždin alluvial aquifer

Geofizika ◽  
2021 ◽  
Vol 38 (1) ◽  
pp. 15-35
Author(s):  
Igor Karlović ◽  
Krešimir Pavlić ◽  
Kristijan Posavec ◽  
Tamara Marković

A combination of different statistical methods and flow duration curves was used to examine hydraulic connection between the Plitvica stream and the surrounding piezometers that capture the groundwater of the Varaždin alluvial aquifer. Also, rainfall quantities over a wider study area were considered to examine the effect of precipitation on Plitvica water levels and groundwater levels. The following statistical methods were used in this paper: the correlation method, the auto- correlation method, and the cross-correlation method. Correlation analysis show that there is generally a significant correlation between the Plitvica water levels and groundwater levels, with positive direction of the correlation. The analysis of auto-correlograms for groundwater and surface water shows that the correlation coefficient value drops below 0.2 after a longer period, which indicates a long-term memory of the system that can be explained by the slow flow and thus slow pressure transfer. Cross-correlation analyses of the time series of the Plitvica water levels and groundwater levels showed a time lag of 1-2 days with a fairly significant cross-correlation coefficient. For precipitation and groundwater levels, the relationship is much weaker, with a lag time of 4-5 days with a weak cross- correlation coefficient. The least time lag, within a day, was established between precipitation and Plitvica water levels. Analyses of the flow duration curves revealed that Plitvica almost completely drains groundwater, except in the vicinity of the piezometer 2178 where Plitvica recharges the aquifer about a quarter of the time.

2021 ◽  
pp. 2250012
Author(s):  
G. F. Zebende ◽  
E. F. Guedes

A correlogram is a statistical tool that is used to check time-series memory by computing the auto-correlation coefficient as a function of the time lag. If the time-series has no memory, then the auto-correlation must be close to zero for any time lag, otherwise if there is a memory, then the auto-correlations must be significantly different from zero. Therefore, based on the robust detrended cross-correlation coefficient, [Formula: see text], we propose the detrended correlogram method in this paper, which will be tested for some time-series (simulated and empirical). This new statistical tool is able to visualize a complete map of the auto-correlation for many time lags and time-scales, and can therefore analyze the memory effect for any time-series.


2010 ◽  
Vol 10 (1) ◽  
pp. 133-137 ◽  
Author(s):  
G. S. Tsolis ◽  
T. D. Xenos

Abstract. In this paper we use the Cross Correlation analysis method in conjunction with the Empirical Mode Decomposition to analyze foF2 signals collected from Rome, Athens and San Vito ionospheric stations, in order to verify the existence of seismo-ionospheric precursors prior to M=6.3 L'Aquila earthquake in Italy. The adaptive nature of EMD allows for removing the geophysical noise from the foF2 signals, and then to calculate the correlation coefficient between them. According to the cross correlation coefficient theory, we expect the stations which located inside the earthquake preparation area, as evaluated using Dobrovolsky equation, to capture the ionospheric disturbances generated by the seismic event. On the other hand the stations outside of this area are expected to remain unaffected. The results of our study are in accordance with the theoretical model, evidencing ionospheric modification prior to L'Aquila earthquake in a certain area around the epicenter. However, it was found that the selection of stations at the limits of the theoretically estimated earthquake preparation area is not the best choice when the cross correlation method is applied, since the modification of the ionosphere over these stations may not be enough for the ionospheric precursors to appear. Our experimental results also show that when a seismic event constitutes the main shock after a series of pre-seismic activity, precursors may appear as early as 22 days prior to the event.


Sensors ◽  
2019 ◽  
Vol 19 (11) ◽  
pp. 2529 ◽  
Author(s):  
Shanshan Tian ◽  
Mengxuan Li ◽  
Yifei Wang ◽  
Xi Chen

Hemiparesis is one of the common sequelae of neurological diseases such as strokes, which can significantly change the gait behavior of patients and restrict their activities in daily life. The results of gait characteristic analysis can provide a reference for disease diagnosis and rehabilitation; however, gait correlation as a gait characteristic is less utilized currently. In this study, a new non-contact electrostatic field sensing method was used to obtain the electrostatic gait signals of hemiplegic patients and healthy control subjects, and an improved Detrended Cross-Correlation Analysis cross-correlation coefficient method was proposed to analyze the obtained electrostatic gait signals. The results show that the improved method can better obtain the dynamic changes of the scaling index under the multi-scale structure, which makes up for the shortcomings of the traditional Detrended Cross-Correlation Analysis cross-correlation coefficient method when calculating the electrostatic gait signal of the same kind of subjects, such as random and incomplete similarity in the trend of the scaling index spectrum change. At the same time, it can effectively quantify the correlation of electrostatic gait signals in subjects. The proposed method has the potential to be a powerful tool for extracting the gait correlation features and identifying the electrostatic gait of hemiplegic patients.


1989 ◽  
Vol 134 ◽  
pp. 100-102
Author(s):  
Dan Maoz

It has been apparent for some time that comparison of continuum and emission-line light curves of AGN may enable determination of the dimensions and structure of the Broad Line Region (BLR)(see Peterson 1988, and references therein). Observations to this end (Antonucci and Cohen 1983, Peterson et al. 1985, Clavel et al. 1987) and their analysis using cross-correlation to find the time lag between line and continuum variations (Gaskell and Sparke 1986), indicate BLR sizes an order of magnitude smaller than allowed by standard photoionization models for several AGN. Gaskell and Peterson (1987) analyzed errors in the cross-correlation method as applied to AGN time series in general and specifically to the Seyfert galaxy Akn120. In order to generalize and extend their analysis we investigated the significance of BLR sizes derived by cross-correlation under different model assumptions and observational circumstances (Maoz and Netzer 1988).


Author(s):  
ALEKSANDRA CZUCHAJ ◽  
FILIP WOLNY ◽  
MAREK MARCINIAK

The aim of the presented research was to analyze the relation between three variables: the daily sum of precipitation, the surface water level and the groundwater level in the Różany Strumień basin located in Poznań, Poland. The correlation coefficient for the subsequent lags for each pair of variables time series has been calculated. The delay with which waters of the basin respond to precipitation varies significantly. Generally, stronger response to rainfall is observed for surface water levels as opposed to groundwater levels.


Author(s):  
D. E. Luzzi ◽  
L. D. Marks ◽  
M. I. Buckett

As the HREM becomes increasingly used for the study of dynamic localized phenomena, the development of techniques to recover the desired information from a real image is important. Often, the important features are not strongly scattering in comparison to the matrix material in addition to being masked by statistical and amorphous noise. The desired information will usually involve the accurate knowledge of the position and intensity of the contrast. In order to decipher the desired information from a complex image, cross-correlation (xcf) techniques can be utilized. Unlike other image processing methods which rely on data massaging (e.g. high/low pass filtering or Fourier filtering), the cross-correlation method is a rigorous data reduction technique with no a priori assumptions.We have examined basic cross-correlation procedures using images of discrete gaussian peaks and have developed an iterative procedure to greatly enhance the capabilities of these techniques when the contrast from the peaks overlap.


2013 ◽  
Vol 58 (2) ◽  
pp. 122-125 ◽  
Author(s):  
O.V. Gnatovskyy ◽  
◽  
A.M. Negriyko ◽  
V.O. Gnatovskyy ◽  
A.V. Sidorenko ◽  
...  

2018 ◽  
Vol 7 (4) ◽  
pp. 191
Author(s):  
Sherwan Sh. Qurtas

Recharge estimation accurately is crucial to proper groundwater resource management, for the groundwater is dynamic and replenished natural resource. Usually recharge estimation depends on the; the water balance, water levels, and precipitation. This paper is studying the south-middle part of Erbil basin, with the majority of Quaternary sediments, the unconfined aquifer system is dominant, and the unsaturated zone is ranging from 15 to 50 meters, which groundwater levels response is moderate. The purpose of this study is quantification the natural recharge from precipitation. The water table fluctuation method is applied; using groundwater levels data of selected monitoring wells, neighboring meteorological station of the wells, and the specific yield of the aquifers. This method is widely used for its simplicity, scientific, realistic, and direct measurement. The accuracy depends on the how much the determination of specific yield is accurate, accuracy of the data, and the extrapolations of recession of groundwater levels curves of no rain periods. The normal annual precipitation there is 420 mm, the average recharge is 89 mm, and the average specific yield is around 0.03. The data of one water year of 2009 and 2010 has taken for some technical and accuracy reasons.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Andrea de Almeida Brito ◽  
Heráclio Alves de Araújo ◽  
Gilney Figueira Zebende

AbstractDue to the importance of generating energy sustainably, with the Sun being a large solar power plant for the Earth, we study the cross-correlations between the main meteorological variables (global solar radiation, air temperature, and relative air humidity) from a global cross-correlation perspective to efficiently capture solar energy. This is done initially between pairs of these variables, with the Detrended Cross-Correlation Coefficient, ρDCCA, and subsequently with the recently developed Multiple Detrended Cross-Correlation Coefficient, $${\boldsymbol{DM}}{{\boldsymbol{C}}}_{{\bf{x}}}^{{\bf{2}}}$$DMCx2. We use the hourly data from three meteorological stations of the Brazilian Institute of Meteorology located in the state of Bahia (Brazil). Initially, with the original data, we set up a color map for each variable to show the time dynamics. After, ρDCCA was calculated, thus obtaining a positive value between the global solar radiation and air temperature, and a negative value between the global solar radiation and air relative humidity, for all time scales. Finally, for the first time, was applied $${\boldsymbol{DM}}{{\boldsymbol{C}}}_{{\bf{x}}}^{{\bf{2}}}$$DMCx2 to analyze cross-correlations between three meteorological variables at the same time. On taking the global radiation as the dependent variable, and assuming that $${\boldsymbol{DM}}{{\boldsymbol{C}}}_{{\bf{x}}}^{{\bf{2}}}={\bf{1}}$$DMCx2=1 (which varies from 0 to 1) is the ideal value for the capture of solar energy, our analysis finds some patterns (differences) involving these meteorological stations with a high intensity of annual solar radiation.


Sign in / Sign up

Export Citation Format

Share Document