A SUBCUTANEOUS INJECTION ASSAY FOR ANTI-ANDROGENS IN THE CHICK

1962 ◽  
Vol 41 (2) ◽  
pp. 268-273 ◽  
Author(s):  
Ralph I. Dorfman

ABSTRACT The stimulating action of testosterone on the chick's comb can be inhibited by the subcutaneous injection of 0.1 mg of norethisterone or Ro 2-7239 (2-acetyl-7-oxo-1,2,3,4,4a,4b,5,6,7,9,10,10a-dodecahydrophenanthrene), 0.5 mg of cortisol or progesterone, and by 4.5 mg of Mer-25 (1-(p-2-diethylaminoethoxyphenyl)-1-phenyl-2-p-methoxyphenyl ethanol). No dose response relationship could be established. Norethisterone was the most active anti-androgen by this test.

2021 ◽  
Vol 34 (01) ◽  
pp. 003-016
Author(s):  
John Michel Warner

AbstractAccording to Hahnemann, homoeopathic medicines must be great immune responses inducers. In crude states, these medicines pose severe threats to the immune system. So, the immune-system of an organism backfires against the molecules of the medicinal substances. The complex immune response mechanism activated by the medicinal molecules can handle any threats which are similar to the threats posed by the medicinal molecules. The intersectional operation of the two sets, medicine-induced immune responses and immune responses necessary to cure diseases, shows that any effective homoeopathic medicine, which is effective against any disease, can induce immune responses which are necessary to cure the specific disease. In this article, this mechanism has been exemplified by the action of Silicea in human body. Also, a neuroimmunological assessment of the route of medicine administration shows that the oral cavity and the nasal cavity are two administration-routes where the smallest doses (sometimes even few molecules) of a particular homoeopathic medicine induce the most effective and sufficient (in amount) purgatory immune responses. Administering the smallest unitary doses of Silicea in the oral route can make significant changes in the vital force line on the dose–response relationship graph. The dose–response relationship graph further implicates that the most effective dose of a medicine must be below the lethality threshold. If multiple doses of any medicine are administered at same intervals, the immune-system primarily engages with the medicinal molecules; but along the passage of time, the engagement line splits into two: one engages with the medicinal molecules and another engages with diseases. The immune system's engagement with the diseases increases along the passage of time, though the engagement with the medicinal molecules gradually falls with the administration of descending doses. Necessarily, I have shown through mathematical logic that the descending doses, though they seem to be funny, can effectively induce the most effective immune responses.


Author(s):  
Satoru Kodama ◽  
Chika Horikawa ◽  
Kazuya Fujihara ◽  
Mariko Hatta ◽  
Yasunaga Takeda ◽  
...  

Atmosphere ◽  
2021 ◽  
Vol 12 (3) ◽  
pp. 371
Author(s):  
Yan Zhang ◽  
Weihua Yang ◽  
Günther Schauberger ◽  
Jianzhuang Wang ◽  
Jing Geng ◽  
...  

Municipal wastewater treatment plants (WWTPs) inside cities have been the major complained sources of odor pollution in China, whereas there is little knowledge about the dose–response relationship to describe the resident complaints caused by odor exposure. This study explored a dose–response relationship between the modelled exposure and the annoyance surveyed by questionnaires. Firstly, the time series of odor concentrations were preliminarily simulated by a dispersion model. Secondly, the perception-related odor exposures were further calculated by combining with the peak to mean factors (constant value 4 (Germany) and 2.3 (Italy)), different time periods of “a whole year”, “summer”, and “nighttime of summer”, and two approaches of odor impact criterion (OIC) (“odor-hour” and “odor concentration”). Thirdly, binomial logistic regression models were used to compare kinds of perception-related odor exposures and odor annoyance by odds ratio, goodness of fit and predictive ability. All perception-related odor exposures were positively associated with odor annoyance. The best goodness of fit was found when using “nighttime of summer” in predicting odor-annoyance responses, which highlights the importance of the time of the day and the time of the year weighting. The best predictive performance for odor perception was determined when the OIC was 4 ou/m3 at the 99th percentile for the odor exposure over time periods of nighttime of summer. The study of dose–response relationship could be useful for the odor management and control of WWTP to maximize the satisfaction of air quality for the residents inside city.


2021 ◽  
Vol 26 (1) ◽  
Author(s):  
Ning Liu ◽  
Yang Peng ◽  
Xinguang Zhong ◽  
Zheng Ma ◽  
Suiping He ◽  
...  

Abstract Background Numerous studies have concentrated on high-dose radiation exposed accidentally or through therapy, and few involve low-dose occupational exposure, to investigate the correlation between low-dose ionizing radiation and changing hematological parameters among medical workers. Methods Using a prospective cohort study design, we collected health examination reports and personal dose monitoring data from medical workers and used Poisson regression and restricted cubic spline models to assess the correlation between changing hematological parameters and cumulative radiation dose and determine the dose-response relationship. Results We observed that changing platelet of 1265 medical workers followed up was statistically different among the cumulative dose groups (P = 0.010). Although the linear trend tested was not statistically significant (Ptrend = 0.258), the non-linear trend tested was statistically significant (Pnon-linear = 0.007). Overall, there was a correlation between changing platelets and cumulative radiation dose (a change of βa 0.008 × 109/L during biennially after adjusting for gender, age at baseline, service at baseline, occupation, medical level, and smoking habits; 95% confidence interval [CI] = 0.003,0.014 × 109/L). Moreover, we also found positive first and then negative dose-response relationships between cumulative radiation dose and changing platelets by restricted cubic spline models, while there were negative patterns of the baseline service not less than 10 years (− 0.015 × 109/L, 95% CI = − 0.024, − 0.007 × 109/L) and radiation nurses(− 0.033 × 109/L, 95% CI = − 0.049, − 0.016 × 109/L). Conclusion We concluded that although the exposure dose was below the limit, medical workers exposed to low-dose ionizing radiation for a short period of time might have increased first and then decreased platelets, and there was a dose-response relationship between the cumulative radiation dose and platelets changing.


Sign in / Sign up

Export Citation Format

Share Document