Cardiac Perforation from Central Venous Catheters: Survival After Cardiac Tamponade in an Infant

PEDIATRICS ◽  
1984 ◽  
Vol 73 (3) ◽  
pp. 333-338 ◽  
Author(s):  
Kishan C. Agarwal ◽  
M. A. Ali Khan ◽  
Anita Falla ◽  
Joseph J. Amato

A 2,210-g infant suffered cardiac tamponade, which resulted from atrial perforation by a central venous catheter. The infant survived due to timely diagnostic and therapeutic intervention. Cardiac tamponade should be suspected in any patient with a central venous catheter whose condition deteriorates suddenly. Immediate chest roentgenogram and echocardiogram may be performed to support the diagnosis; but when the patient's condition is deteriorating, a diagnostic (and therapeutic as well !) pericardiocentesis should be performed without waiting for other diagnostic measures. A review of clinical recognition and diagnostic measures for cardiac perforation and tamponade is presented. Preventive measures to avoid this fatal complication of central venous catheters are suggested, and therapeutic interventions are outlined.

PEDIATRICS ◽  
1982 ◽  
Vol 70 (1) ◽  
pp. 139-140
Author(s):  
James C. Opitz ◽  
William Toyama

Cardiac tamponade is a well-recognized complication of cardiac catheterization. It is also a known complication of central venous catheters that have been inserted for nutritional as well as other purposes.1-8 Dudrick et al9 first documented the clinical application of total parenteral nutrition and, since that description, hyperalimentation has been used with increasing frequency. This paper describes two infants of very low birth weight who survived after developing pericardial tamponade caused by perforation by a central venous catheter. To our knowledge, only two premature infants are reported to have survived this complication. When rapid deterioration is noted in any infant with a central venous catheter in place, this perforation must be rapidly considered in the differential diagnosis.


2020 ◽  
pp. 112972982094345
Author(s):  
Maryanne Z A Mariyaselvam ◽  
Vikesh Patel ◽  
Adam Sawyer ◽  
James A Richardson ◽  
Jonathan Dean ◽  
...  

Background: Central venous catheter guidewire retention is classed as a ‘never event’ in the United Kingdom, with the potential for significant patient harm. If the retained guidewire remains within the central venous catheter lumen, bedside techniques may facilitate guidewire retrieval. However, these techniques may be ineffective if the guidewire has already passed below skin level. We investigated a novel ‘suck out’ technique for bedside guidewire retrieval and compared this against traditional retrieval methods. Methods: Simulation 1: in a benchtop model, seven different central venous catheters had their corresponding guidewire placed in the last 2 cm of the catheter tip which was immersed horizontally in fluid. A 50-mL syringe was attached to the distal lumen central venous catheter hub and suction applied for 5 s, and the distance of guidewire retraction was recorded. Simulation 2: a central venous catheter guidewire was intentionally retained within the catheter at either 5 cm above or below skin level in a pigskin model. Simple catheter withdrawal, catheter clamping withdrawal and the ‘suck out’ method were compared for efficacy using Fisher’s exact test. Results: Simulation 1: retained guidewires were retracted by 13 cm on average. Simulation 2: when guidewires were retained 5 cm above skin level, all retrieval methods were 100% effective; however, when retained 5 cm below skin level, simple catheter withdrawal was ineffective, clamping and withdrawal was only 10% effective and the ‘suck out’ technique was 90% effective (p < 0.001). Conclusion: The ‘suck out’ technique can effectively retract guidewires retained within central venous catheter lumens and demonstrates superiority over traditional methods of retained guidewire extraction in simulated models.


2021 ◽  
pp. 0310057X2110242
Author(s):  
Adrian D Haimovich ◽  
Ruoyi Jiang ◽  
Richard A Taylor ◽  
Justin B Belsky

Vasopressors are ubiquitous in intensive care units. While central venous catheters are the preferred route of infusion, recent evidence suggests peripheral administration may be safe for short, single-agent courses. Here, we identify risk factors and develop a predictive model for patient central venous catheter requirement using the Medical Information Mart for Intensive Care, a single-centre dataset of patients admitted to an intensive care unit between 2008 and 2019. Using prior literature, a composite endpoint of prolonged single-agent courses (>24 hours) or multi-agent courses of any duration was used to identify likely central venous catheter requirement. From a cohort of 69,619 intensive care unit stays, there were 17,053 vasopressor courses involving one or more vasopressors that met study inclusion criteria. In total, 3807 (22.3%) vasopressor courses involved a single vasopressor for less than six hours, 7952 (46.6%) courses for less than 24 hours and 5757 (33.8%) involved multiple vasopressors of any duration. Of these, 3047 (80.0%) less than six-hour and 6423 (80.8%) less than 24-hour single vasopressor courses used a central venous catheter. Logistic regression models identified associations between the composite endpoint and intubation (odds ratio (OR) 2.36, 95% confidence intervals (CI) 2.16 to 2.58), cardiac diagnosis (OR 0.72, CI 0.65 to 0.80), renal impairment (OR 1.61, CI 1.50 to 1.74), older age (OR 1.002, Cl 1.000 to 1.005) and vital signs in the hour before initiation (heart rate, OR 1.006, CI 1.003 to 1.009; oxygen saturation, OR 0.996, CI 0.993 to 0.999). A logistic regression model predicting the composite endpoint had an area under the receiver operating characteristic curve (standard deviation) of 0.747 (0.013) and an accuracy of 0.691 (0.012). This retrospective study reveals a high prevalence of short vasopressor courses in intensive care unit settings, a majority of which were administered using central venous catheters. We identify several important risk factors that may help guide clinicians deciding between peripheral and central venous catheter administration, and present a predictive model that may inform future prospective trials.


CHEST Journal ◽  
2013 ◽  
Vol 144 (4) ◽  
pp. 299A
Author(s):  
Rakesh Vadde ◽  
Meenakshi Ghosh ◽  
Saurav Pokharel ◽  
Setu Patolia ◽  
Dharani Narendra ◽  
...  

2004 ◽  
Vol 9 (2) ◽  
pp. 80-85 ◽  
Author(s):  
Phllip Lum

Abstract Purpose: To validate the formula-based central venous catheter (CVC) length measurement “tailored” to individual's height and access site for predicting optimum SVC tip position. Method: A prospective study of 3 percutaneous insertion sites (PICC, SCC and JC). Formula-based “LUM'S CVC MEASUREMENT GUIDE” was used to determine the catheter length. Results: Overall, 97% (373) of the total 382 insertions were successfully placed with CVC tip in the distal SVC (SVC between carina and atrio-cava junction) location. Conclusion: The “tailored fit” formula to individual patient height is a reliable tool to predict CVC length. Appropriate catheter length can greatly reduce the guesswork and possibility of complications related to tip malposition.


2019 ◽  
Vol 21 (3) ◽  
pp. 336-341
Author(s):  
Salvatore Mandolfo ◽  
Adriano Anesi ◽  
Milena Maggio ◽  
Vanina Rognoni ◽  
Franco Galli ◽  
...  

Background: Catheter-related bloodstream infections caused by Staphylococcus aureus represent one of the most fearful infections in chronic haemodialysis patients with tunnelled central venous catheters. Current guidelines suggest prompt catheter removal in patients with positive blood cultures for S. aureus. This manoeuvre requires inserting a new catheter into the same vein or another one and is not without its risks. Methods: A protocol based on early, prompt diagnosis and treatment has been utilized in our renal unit since 2012 in an attempt to salvage infected tunnelled central venous catheters. We prospectively observed 247 tunnelled central venous catheters in 173 haemodialysis patients involving 167,511 catheter days. Results: We identified 113 catheter-related bloodstream infections (0.67 episodes per 1000 days/tunnelled central venous catheter). Forty were caused by S. aureus, including 19 by methicillin-resistant S. aureus (79% saved) and 21 by methicillin-sensitive S. aureus (90% saved), of which 34 (85%) were treated successfully. Eight recurrences occurred and six (75%) were successfully treated. A greater than 12 h time to blood culture positivity for S. aureus was a good prognostic index for successful therapy and tunnelled central venous catheter rescue. Conclusion: Our data lead us to believe that it is possible to successfully treat catheter-related bloodstream infection caused by S. aureus and to avoid removing the tunnelled central venous catheter in many more cases than what has been reported in the literature. On the third day, it is mandatory to decide whether to replace the tunnelled central venous catheter or to carry on with antibiotic therapy. Apyrexia and amelioration of laboratory parameters suggest continuing systemic and antibiotic lock therapy for no less than 4 weeks, otherwise, tunnelled central venous catheter removal is recommended.


2012 ◽  
Vol 13 (4) ◽  
pp. 530-533 ◽  
Author(s):  
Micha Y. Shamir ◽  
Mauro Pittiruti ◽  
Antonio La Greca ◽  
Giancarlo Scoppettuolo

Sign in / Sign up

Export Citation Format

Share Document